The EANM practice guidelines for bone scintigraphy Van den Wyngaert, T.; Strobel, K.; Kampen, W. U. ...
European journal of nuclear medicine and molecular imaging,
08/2016, Volume:
43, Issue:
9
Journal Article
Peer reviewed
Open access
Purpose
The radionuclide bone scan is the cornerstone of skeletal nuclear medicine imaging. Bone scintigraphy is a highly sensitive diagnostic nuclear medicine imaging technique that uses a ...radiotracer to evaluate the distribution of active bone formation in the skeleton related to malignant and benign disease, as well as physiological processes.
Methods
The European Association of Nuclear Medicine (EANM) has written and approved these guidelines to promote the use of nuclear medicine procedures of high quality.
Conclusion
The present guidelines offer assistance to nuclear medicine practitioners in optimizing the diagnostic procedure and interpreting bone scintigraphy. These guidelines describe the protocols that are currently accepted and used routinely, but do not include all existing procedures. They should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, VSZLJ, ZAGLJ
IMPORTANCE: Medical imaging increased rapidly from 2000 to 2006, but trends in recent years have not been analyzed. OBJECTIVE: To evaluate recent trends in medical imaging. DESIGN, SETTING, AND ...PARTICIPANTS: Retrospective cohort study of patterns of medical imaging between 2000 and 2016 among 16 million to 21 million patients enrolled annually in 7 US integrated and mixed-model insurance health care systems and for individuals receiving care in Ontario, Canada. EXPOSURES: Calendar year and country (United States vs Canada). MAIN OUTCOMES AND MEASURES: Use of computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and nuclear medicine imaging. Annual and relative imaging rates by imaging modality, country, and age (children <18 years, adults 18-64 years, and older adults ≥65 years). RESULTS: Overall, 135 774 532 imaging examinations were included; 5 439 874 (4%) in children, 89 635 312 (66%) in adults, and 40 699 346 (30%) in older adults. Among adults and older adults, imaging rates were significantly higher in 2016 vs 2000 for all imaging modalities other than nuclear medicine. For example, among older adults, CT imaging rates were 428 per 1000 person-years in 2016 vs 204 per 1000 in 2000 in US health care systems and 409 per 1000 vs 161 per 1000 in Ontario; for MRI, 139 per 1000 vs 62 per 1000 in the United States and 89 per 1000 vs 13 per 1000 in Ontario; and for ultrasound, 495 per 1000 vs 324 per 1000 in the United States and 580 per 1000 vs 332 per 1000 in Ontario. Annual growth in imaging rates among US adults and older adults slowed over time for CT (from an 11.6% annual percentage increase among adults and 9.5% among older adults in 2000-2006 to 3.7% among adults in 2013-2016 and 5.2% among older adults in 2014-2016) and for MRI (from 11.4% in 2000-2004 in adults and 11.3% in 2000-2005 in older adults to 1.3% in 2007-2016 in adults and 2.2% in 2005-2016 in older adults). Patterns in Ontario were similar. Among children, annual growth for CT stabilized or declined (United States: from 10.1% in 2000-2005 to 0.8% in 2013-2016; Ontario: from 3.3% in 2000-2006 to −5.3% in 2006-2016), but patterns for MRI were similar to adults. Changes in annual growth in ultrasound were smaller among adults and children in the United States and Ontario compared with CT and MRI. Nuclear medicine imaging declined in adults and children after 2006. CONCLUSIONS AND RELEVANCE: From 2000 to 2016 in 7 US integrated and mixed-model health care systems and in Ontario, rates of CT and MRI use continued to increase among adults, but at a slower pace in more recent years. In children, imaging rates continued to increase except for CT, which stabilized or declined in more recent periods. Whether the observed imaging utilization was appropriate or was associated with improved patient outcomes is unknown.
The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy ...Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG-142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG-40 report on quality assurance and second, to add recommendations for asymmetric jaws, multileaf collimation (MLC), and dynamic/virtual wedges. The TG accomplished the update to TG-40, specifying new test and tolerances, and has added recommendations for not only the new ancillary delivery technologies but also for imaging devices that are part of the linear accelerator. The imaging devices include x-ray imaging, photon portal imaging, and cone-beam CT. The TG report was designed to account for the types of treatments delivered with the particular machine. For example, machines that are used for radiosurgery treatments or intensity-modulated radiotherapy (IMRT) require different tests and/or tolerances. There are specific recommendations for MLC quality assurance for machines performing IMRT. The report also gives recommendations as to action levels for the physicists to implement particular actions, whether they are inspection, scheduled action, or immediate and corrective action. The report is geared to be flexible for the physicist to customize the QA program depending on clinical utility. There are specific tables according to daily, monthly, and annual reviews, along with unique tables for wedge systems, MLC, and imaging checks. The report also gives specific recommendations regarding setup of a QA program by the physicist in regards to building a QA team, establishing procedures, training of personnel, documentation, and end-to-end system checks. The tabulated items of this report have
been considerably expanded as compared with the original TG-40 report and the recommended tolerances accommodate differences in the intended use of the machine functionality (non-IMRT, IMRT, and stereotactic delivery).
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode.
A stand-alone, trolley-mounted, prototype prompt ...gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan.
In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and -0.4 ± 0.9 mm for the vertex field.
This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.
Full text
Available for:
GEOZS, IJS, NUK, OILJ, UL, UM, UPUK
Peptide receptor radionuclide therapy (PRRT) using radiolabelled somatostatin analogues such as 177-lutetium DOTATATE is an effective treatment modality for neuroendocrine tumours, paragangliomas, ...and neuroblastomas. However, renal and haematopoietic toxicities are the major limitations of this therapeutic approach. The renal toxicity of PRRT is mediated by renal proximal tubular reabsorption and interstitial retention of the radiolabelled peptides resulting in excessive renal irradiation that can be dose-limiting. To protect the kidneys from PRRT-induced radiation nephropathy, basic amino acids are infused during PRRT as they competitively bind to the proximal tubular cells and prevent uptake of the radionuclide. In adults, 1 L of a basic amino acid solution consisting of arginine and lysine is infused over 4 h commencing 30 min prior to PRRT. However, this volume of amino acids infused over 4 h is excessive in small children and can result in hemodynamic overload. This is all the more relevant in paediatric oncology, as many of the children may have been heavily pretreated and so may have treatment-related renal and or cardiac impairment. We have therefore developed the following guidelines for safe paediatric dosing of renal protective amino acid infusions during PRRT. Our recommendations have been made taking into consideration the renal physiology in small children and the principles of safe fluid management in children.
Background
Pulmonary embolism is a leading cause of pregnancy‐related death. An accurate diagnosis in pregnant patients is crucial to prevent untreated pulmonary embolism as well as unnecessary ...anticoagulant treatment and future preventive measures. Applied imaging techniques might perform differently in these younger patients with less comorbidity and altered physiology, who largely have been excluded from diagnostic studies.
Objectives
To determine the diagnostic accuracy of computed tomography pulmonary angiography (CTPA), lung scintigraphy and magnetic resonance angiography (MRA) for the diagnosis of pulmonary embolism during pregnancy.
Search methods
We searched MEDLINE and Embase until July 2015. We used included studies as seeds in citations searches and in 'find similar' functions and searched reference lists. We approached experts in the field to help us identify non‐indexed studies.
Selection criteria
We included consecutive series of pregnant patients suspected of pulmonary embolism who had undergone one of the index tests (computed tomography (CT) pulmonary angiography, lung scintigraphy or MRA) and clinical follow‐up or pulmonary angiography as a reference test.
Data collection and analysis
Two review authors performed data extraction and quality assessment. We contacted investigators of potentially eligible studies to obtain missing information. In the primary analysis, we regarded inconclusive index test results as a negative reference test, and treatment for pulmonary embolism after an inconclusive index test as a positive reference test.
Main results
We included 11 studies (four CTPA, five lung scintigraphy, two both) with a total of 695 CTPA and 665 lung scintigraphy results. Lung scintigraphy was applied by different techniques. No MRA studies matched our inclusion criteria.
Overall, risk of bias and concerns regarding applicability were high in all studies as judged in light of the review research question, as was heterogeneity in study methods. We did not undertake meta‐analysis. All studies used clinical follow‐up as a reference standard, none in a manner that enabled reliable identification of false positives. Sensitivity and negative predictive value were therefore the only valid test accuracy measures.
The median negative predictive value for CTPA was 100% (range 96% to 100%). Median sensitivity was 83% (range 0% to 100%).
The median negative predictive value for lung scintigraphy was 100% (range 99% to 100%). Median sensitivity was 100% (range 0% to 100%).
The median frequency of inconclusive results was 5.9% (range 0.9% to 36%) for CTPA and 4.0% (range 0% to 23%) for lung scintigraphy. The overall median prevalence of pulmonary embolism was 3.3% (range 0.0% to 8.7%).
Authors' conclusions
Both CTPA and lung scintigraphy seem appropriate for exclusion of pulmonary embolism during pregnancy. However, the quality of the evidence mandates cautious adoption of this conclusion. Important limitations included poor reference standards, necessary assumptions in the analysis regarding inconclusive test results and the inherent inability of included studies to identify false positives. It is unclear which test has the highest accuracy. There is a need for direct comparisons between diagnostic methods, including MR, in prospective randomized diagnostic studies.
To determine in a group of patients with progressive metastatic neuroendocrine tumors (PM-NETs) treated with 177Lu-DOTATATE whether a correlation exists between somatostatin receptor (SSTR)-2 ...expression in various tumors on baseline 68Ga-DOTATATE PET and their response to therapy. A secondary aim was to determine whether an association exists between tumor product of diameter (POD) and PET-derived Krenning score.
Patients treated PM-NETs who had SSTR-2 overexpression (SSTR-RADS 5) on screening 68Ga-DOTATATE PET and CT at baseline and 3 months after therapy completion were included. Marker lesions on baseline CT were reassessed on CT after therapy using adapted Southwest Oncology Group solid tumor evaluation criteria. For each lesion, bidimensional diameter on CT and SSTR expression on PET (SSTR-RADS uptake score & PET-derived Krenning score) were recorded. Logistic regression models fitted through generalized estimating equations were used to assess for an association between SSTR expression and response to therapy, or lesion's POD.
Forty-one patients with SSTR-RADS 5 PM-NETs treated with 177Lu-DOTATATE were included. There were 135 marker lesions (mean 3.2 lesions/patient) with Krenning score of 4 (n = 74), 3 (n = 44) or 2 (n = 17). There was no association found between SSTR-2 expression, as determined by SSTR-RADS uptake score or PET-derived Krenning score, and POD or response to therapy.
In patients with SSTR-RADS 5 PM-NETs treated with 177Lu-DOTATATE, there was similar response to therapy for all lesions with PET-generated Krenning score ≥2. No correlation was found between lesion's POD and level of tracer uptake.