E-resources
Peer reviewed
-
Su, Xin; Cutinella, Matthew; Agran, Jason E; Dinsmoor, David A
Neuromodulation (Malden, Mass.) 20, Issue: 8Journal Article
The goal of this study was to compare the motor response to sacral neuromodulation (SNM) with different pairs of stimulating electrodes in anesthetized and awake sheep. Similar to SNM clinical use in humans, the InterStim quadripolar tined lead was implanted adjacent to the S3 nerve root in sheep and bipolar stimulation was configured with one electrode negative and one electrode positive on the four contacts (0 most distal to device, 1, 2, and 3 most proximal). Electrode 3-cathode and electrode 0-anode (3-/0+) stimulation had the lowest visual response threshold (0.46 ± 0.14V, anesthetized, 0.56 ± 0.21V, conscious), representing the most sensitive stimulation. Stimulation on electrode 0 (0-/1+) had the highest response threshold among tested electrodes (2.70 ± 0.23V, anesthetized, 3.38 ± 0.96V, conscious). The order according to response threshold from low to high was 3 < 2 < 1 < 0. The triggered response by 3-/0+ stimulation solely occurred in the perineum, tail, or bellows. In contrast, the 0-/1+ stimulation frequently evoked response in gluteal and thigh regions. The electromyographic activities from the anus were sensitive to low intensities of stimulation on electrode 3 (e.g., 3-/0+, 3-/2+). Objective motor responses to SNM as a functional indicator for optimal lead placement may be used to demonstrate that the contact which is most proximal to the foramen (electrode 3) is an optimal electrode to trigger an "on-target" response to lower intensity stimulation. Data from this preclinical work suggest that there are several principles that may be referenced to simplify and expedite the programming process in clinical practice.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.