Akademska digitalna zbirka SLovenije - logo
E-resources
Peer reviewed Open access
  • Baracchini, E; Benussi, L; Bianco, S; Capoccia, C; Caponero, M; Cavoto, G; Cortez, A; Costa, I A; E Di Marco; D'Imperio, G; Dho, G; Iacoangeli, F; Maccarrone, G; Marafini, M; Mazzitelli, G; Messina, A; Nobrega, R A; Orlandi, A; Paoletti, E; Passamonti, L; Petrucci, F; Piccolo, D; Pierluigi, D; Pinci, D; Renga, F; Rosatelli, F; Russo, A; Saviano, G; Tomassini, S

    Journal of instrumentation, 10/2020, Volume: 15, Issue: 10
    Journal Article

    The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF4 based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost full detection efficiency in the whole detector volume was found with both mixtures, while a light yield about 20% larger for the 60/40 was found. The electrostatic stability was tested by monitoring voltages and currents during 25 days. The detector worked in very stable and safe condition for the whole period. In the presence of less CF4, a larger probability of unstable events was clearly detected.