Hui Jiang; Tao Shao; Cheng Zhang; Wenfeng Li; Ping Yan; Xueke Che; Schamiloglu, Edl
IEEE transactions on dielectrics and electrical insulation, 08/2013, Volume: 20, Issue: 4Journal Article
A charge-voltage Lissajous figure is a standard method for the electrical diagnostics of DBD discharges. Based on a repetitive nanosecond-pulse generator, some experiments on surface discharges are carried out in open air. The effects of applied voltage amplitude, pulse repetition frequency, electrode gap spacing, and electrode width on the characteristics of the Lissajous figures are presented in this paper. Results show that two different kinds of typical discharge characteristics are observed, and the discharge characteristics vary between these two kinds of discharges when the discharge parameters change. The applied voltage has little effect on the shape of the Lissajous figure, and the total and barrier capacitances of actuator. Both transported charge and energy per pulse are proportional to the applied voltage amplitude. The applied voltage plays an important role in the discharge uniformity, intensity and length of surface plasmas. The pulse repetition frequency plays an important role in the energy and discharge intensity accumulation and has no effect the electrical parameters of surface discharges. The shape of the Lissajous figure gradually changes with the electrode gap and the transported charges proportionally decrease as the electrode gap increases. There is a transition gap spacing to obtain the maximum plasma energy and to achieve a relatively uniform plasma. The capacitances of the actuator, the transported charges and energy per pulse increase with the electrode width. The intensity of surface discharges is little affected by the electrode width, but the plasma uniformity tends to worsen with the increasing width. There is a corresponding relationship between the shape of the Lissajous figures and the uniformity of plasma distribution. The almond-like Lissajous figure is attained with a compromise between the electrode gap and width.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.