E-resources
Peer reviewed
-
Palit, Sayani; Singh, Kanishk; Lou, Bih-Show; Her, Jim-Long; Pang, See-Tong; Pan, Tung-Ming
Sensors and actuators. B, Chemical, 05/2020, Volume: 310Journal Article
•InZnxOy sensing film on flexible PET using a simple sol-gel method for an EGFET pH sensor.•InZnxOy EGFET sensor showed an excellent sensing performance in terms of sensitivity, hysteresis and drift.•InZnxOy EGFET flexible biosensor exhibited a high sensitivity of 10.69 mV/log(dopamine) in the range from 1 fM to 1 nM. With the aim of a simple, label-free, and highly specific dopamine detection, we proposed an indium-zinc oxide (InZnxOy) sensing film on flexible PET using a simple sol-gel method for an extended gate field-effect transistor (EGFET) sensor. In this study, X-ray diffraction, atomic force spectroscopy, and X-ray photoelectron spectroscopy were used to characterize the structural, morphological, and chemical features, respectively. The InZnxOy based EGFET sensor showed a super Nernstian pH response of 61.53 mV/pH with an excellent linearity of 0.995 (in the range of pH 2–12), a low hysteresis voltage of ∼ 3 mV (in the pH loop of 7→4→7→10→7) and a small drift rate of 3.52 mV/h (in the pH 7). Correspondingly, to investigate the impact of mechanical bending on the pH performances of InZnxOy based flexible EGFET sensor, a couple of bending tests, which include different bending radius and bending cycles, were performed. The device showed better mechanical durability up to 1500 bending cycles for pH sensitivity. In order to achieve the label-free detection of dopamine, the InZnxOy on PET-based EGFET was functionalized using a synthetic receptor named 4-carboxylphenylboronic acid, for the covalent binding of dopamine on the sensing surface. The sensitivity of dopamine is 10.69 mV/log(dopamine) with linearity 0.998 within the dopamine concentration range of 1 fM–1 nM and the limit of detection value is 0.523 fM. In addition, this InZnxOy based EGFET biosensor showed excellent selectivity to dopamine over other interfering chemicals. Our proposed InZnxOy EGFET biosensor was successfully applied to detect dopamine level in the real samples like rat blood serum and rat brain.
Author
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.