E-resources
Peer reviewed
Open access
-
Rahbek, Sofie; Schakel, Tim; Mahmood, Faisal; Madsen, Kristoffer H.; Philippens, Marielle E.P.; Hanson, Lars G.
Magnetic resonance in medicine, April 2023, Volume: 89, Issue: 4Journal Article
Purpose The diffusion‐weighted SPLICE (split acquisition of fast spin‐echo signals) sequence employs split‐echo rapid acquisition with relaxation enhancement (RARE) readout to provide images almost free of geometric distortions. However, due to the varying T2$$ {}_2 $$‐weighting during k‐space traversal, SPLICE suffers from blurring. This work extends a method for controlling the spatial point spread function (PSF) while optimizing the signal‐to‐noise ratio (SNR) achieved by adjusting the flip angles in the refocusing pulse train of SPLICE. Methods An algorithm based on extended phase graph (EPG) simulations optimizes the flip angles by maximizing SNR for a flexibly chosen predefined target PSF that describes the desired k‐space density weighting and spatial resolution. An optimized flip angle scheme and a corresponding post‐processing correction filter which together achieve the target PSF was tested by healthy subject brain imaging using a clinical 1.5 T scanner. Results Brain images showed a clear and consistent improvement over those obtained with a standard constant flip angle scheme. SNR was increased and apparent diffusion coefficient estimates were more accurate. For a modified Hann k‐space weighting example, considerable benefits resulted from acquisition weighting by flip angle control. Conclusion The presented flexible method for optimizing SPLICE flip angle schemes offers improved MR image quality of geometrically accurate diffusion‐weighted images that makes the sequence a strong candidate for radiotherapy planning or stereotactic surgery.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.