E-resources
-
Busana, Mattia; Giosa, Lorenzo; Cressoni, Massimo; Gasperetti, Alessio; Di Girolamo, Luca; Martinelli, Alessandra; Sonzogni, Aurelio; Lorini, Luca; Palumbo, Maria Michela; Romitti, Federica; Gattarello, Simone; Steinberg, Irene; Herrmann, Peter; Meissner, Konrad; Quintel, Michael; Gattinoni, Luciano
Journal of applied physiology (1985), 03/2021, Volume: 130, Issue: 3Journal Article
COVID-19 infection may lead to acute respiratory distress syndrome (CARDS) where severe gas exchange derangements may be associated, at least in the early stages, only with minor pulmonary infiltrates. This may suggest that the shunt associated to the gasless lung parenchyma is not sufficient to explain CARDS hypoxemia. We designed an algorithm (Vent Q ), based on the same conceptual grounds described by J.B. West in 1969. We set 498 ventilation-perfusion (V /Q) compartments and, after calculating their blood composition (PO , PCO , and pH), we randomly chose 10 combinations of five parameters controlling a bimodal distribution of blood flow. The solutions were accepted if the predicted PaO and PaCO were within 10% of the patient's values. We assumed that the shunt fraction equaled the fraction of non-aerated lung tissue at the CT quantitative analysis. Five critically-ill patients later deceased were studied. The PaO /FiO was 91.1 ± 18.6 mmHg and PaCO 69.0 ± 16.1 mmHg. Cardiac output was 9.58 ± 0.99 L/min. The fraction of non-aerated tissue was 0.33 ± 0.06. The model showed that a large fraction of the blood flow was likely distributed in regions with very low V /Q (Q = 0.06 ± 0.02) and a smaller fraction in regions with moderately high V /Q. Overall LogSD, Q was 1.66 ± 0.14, suggestive of high V /Q inequality. Our data suggest that shunt alone cannot completely account for the observed hypoxemia and a significant V /Q inequality must be present in COVID-19. The high cardiac output and the extensive microthrombosis later found in the autopsy further support the hypothesis of a pathological perfusion of non/poorly ventilated lung tissue. Hypothesizing that the non-aerated lung fraction as evaluated by the quantitative analysis of the lung computed tomography (CT) equals shunt (V /Q = 0), we used a computational approach to estimate the magnitude of the ventilation-perfusion inequality in severe COVID-19. The results show that a severe hyperperfusion of poorly ventilated lung region is likely the cause of the observed hypoxemia. The extensive microthrombosis or abnormal vasodilation of the pulmonary circulation may represent the pathophysiological mechanism of such V /Q distribution.
Author
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.