E-resources
Peer reviewed
-
Bang, Ji Young; Hough, Matthew; Hawes, Robert H; Varadarajulu, Shyam
The American journal of gastroenterology, 04/2020, Volume: 115, Issue: 4Journal Article
Exposure to ionizing radiation remains a hazard for patients and healthcare providers. We evaluated the utility of an artificial intelligence (AI)-enabled fluoroscopy system to minimize radiation exposure during image-guided endoscopic procedures. We conducted a prospective study of 100 consecutive patients who underwent fluoroscopy-guided endoscopic procedures. Patients underwent interventions using either conventional or AI-equipped fluoroscopy system that uses ultrafast collimation to limit radiation exposure to the region of interest. The main outcome measure was to compare radiation exposure with patients, which was measured by dose area product. Secondary outcome was radiation scatter to endoscopy personnel measured using dosimeter. Of 100 patients who underwent procedures using traditional (n = 50) or AI-enabled (n = 50) fluoroscopy systems, there was no significant difference in demographics, body mass index, procedural type, and procedural or fluoroscopy time between the conventional and the AI-enabled fluoroscopy systems. Radiation exposure to patients was lower (median dose area product 2,178 vs 5,708 mGym, P = 0.001) and scatter effect to endoscopy personnel was less (total deep dose equivalent 0.28 vs 0.69 mSv; difference of 59.4%) for AI-enabled fluoroscopy as compared to conventional system. On multivariate linear regression analysis, after adjusting for patient characteristics, procedural/fluoroscopy duration, and type of fluoroscopy system, only AI-equipped fluoroscopy system (coefficient 3,331.9 95% confidence interval: 1,926.8-4,737.1, P < 0.001) and fluoroscopy duration (coefficient 813.2 95% confidence interval: 640.5-985.9, P < 0.001) were associated with radiation exposure. The AI-enabled fluoroscopy system significantly reduces radiation exposure to patients and scatter effect to endoscopy personnel (see Graphical abstract, Supplementary Digital Content, http://links.lww.com/AJG/B461).
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.