E-resources
Peer reviewed
-
Vignon, Philippe; Repessé, Xavier; Bégot, Emmanuelle; Léger, Julie; Jacob, Christophe; Bouferrache, Koceila; Slama, Michel; Prat, Gwenaël; Vieillard-Baron, Antoine
American journal of respiratory and critical care medicine, 04/2017, Volume: 195, Issue: 8Journal Article
Assessment of fluid responsiveness relies on dynamic echocardiographic parameters that have not yet been compared in large cohorts. To determine the diagnostic accuracy of dynamic parameters used to predict fluid responsiveness in ventilated patients with a circulatory failure of any cause. In this multicenter prospective study, respiratory variations of superior vena cava diameter (∆SVC) measured using transesophageal echocardiography, of inferior vena cava diameter (∆IVC) measured using transthoracic echocardiography, of the maximal Doppler velocity in left ventricular outflow tract (∆VmaxAo) measured using either approach, and pulse pressure variations (∆PP) were recorded with the patient in the semirecumbent position. In each patient, a passive leg raise was performed and an increase of aortic velocity time integral greater than or equal to 10% defined fluid responsiveness. Among 540 patients (379 men; age, 65 ± 13 yr; Simplified Acute Physiological Score II, 59 ± 18; Sequential Organ Failure Assessment, 10 ± 3), 229 exhibited fluid responsiveness (42%). ∆PP, ∆VmaxAo, ∆SVC, and ∆IVC could be measured in 78.5%, 78.0%, 99.6%, and 78.1% of cases, respectively. ∆SVC greater than or equal to 21%, ∆VmaxAo greater than or equal to 10%, and ∆IVC greater than or equal to 8% had a sensitivity of 61% (95% confidence interval, 57-66%), 79% (75-83%), and 55% (50-59%), respectively, and a specificity of 84% (81-87%), 64% (59-69%), and 70% (66-75%), respectively. The area under the receiver operating characteristic curve of ∆SVC was significantly greater than that of ∆IVC (P = 0.02) and ∆PP (P = 0.01). ∆VmaxAo had the best sensitivity and ∆SVC the best specificity in predicting fluid responsiveness. ∆SVC had a greater diagnostic accuracy than ∆IVC and ∆PP, but its measurement requires transesophageal echocardiography.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.