E-resources
-
Amoroso, A.; Ferroli, R. Baldini; Balossino, I.; Bertani, M.; Bettoni, D.; Bortone, A.; Calcaterra, A.; Cerioni, S.; Cheng, W.; Cibinetto, G.; Ramusino, A. Cotta; Cossio, F.; Rolo, M. Da Rocha; Mori, F. De; Denig, A.; Destefanis, M.; Dong, J.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Garillon, B.; Garzia, I.; Gatta, M.; Giraudo, G.; Gramigna, S.; Greco, M.; Gülker, P.; Guo, Y.P.; Lauth, W.; Lavezzi, L.; Maggiora, M.; Malaguti, R.; Mangoni, A.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Pace, E.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Redmer, C. F.; Ripka, M.; Rivetti, A.; Rosner, C.; Scodeggio, M.; Sosio, S.; Spataro, S.
Journal of instrumentation, 06/2020, Volume: 15, Issue: 6Journal Article
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber (μTPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to 108Hz/cm2. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the μTPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.
Author
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.