E-resources
-
Limmathurotsakul, Direk; Turner, Elizabeth L.; Wuthiekanun, Vanaporn; Thaipadungpanit, Janjira; Suputtamongkol, Yupin; Chierakul, Wirongrong; Smythe, Lee D.; Day, Nicholas P. J.; Cooper, Ben; Peacock, Sharon J.
Clinical infectious diseases, 08/2012, Volume: 55, Issue: 3Journal Article
Background. We observed that some patients with clinical leptospirosis supported by positive results of rapid tests were negative for leptospirosis on the basis of our diagnostic gold standard, which involves isolation of Leptospira species from blood culture and/or a positive result of a microscopic agglutination test (MAT). We hypothesized that our reference standard was imperfect and used statistical modeling to investigate this hypothesis. Methods. Data for 1652 patients with suspected leptospirosis recruited during three observational studies and one randomized control trial that described the application of culture, MAT, immunofluorescence assay (IFA), lateral flow (LF) and/or PCR targeting the 16S rRNA gene were reevaluated using Bayesian latent class models and random-effects meta-analysis. Results. The estimated sensitivities of culture alone, MAT alone, and culture plus MAT (for which the result was considered positive if one or both tests had a positive result) were 10.5% (95% credible interval CrI, 2.7%—27.5%), 49.8% (95% CrI, 37.6%—60.8%), and 55.5% (95% CrI, 42.9%—67.7%), respectively. These low sensitivities were present across all 4 studies. The estimated specificity of MAT alone (and of culture plus MAT) was 98.8% (95% CrI, 92.8%—100.0%). The estimated sensitivities and specificities of PCR (52.7% 95% CrI, 45.2%— 60.6% and 97.2% 95% CrI, 92.0%—99.8%, respectively), lateral flow test (85.6% 95% CrI, 77.5%—93.2% and 96.2% 95% CrI, 87.7%—99.8%, respectively), and immunofluorescence assay (45.5% 95% CrI, 33.3%—60.9% and 96.8% 95% CrI, 92.8%—99.8%, respectively) were considerably different from estimates in which culture plus MAT was considered a perfect gold standard test. Conclusions. Our findings show that culture plus MAT is an imperfect gold standard against which to compare alterative tests for the diagnosis of leptospirosis. Rapid point-of-care tests for this infection would bring an important improvement in patient care, but their future evaluation will require careful consideration of the reference test(s) used and the inclusion of appropriate statistical models.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.