Jensen, Lisette Okkels, MD, PhD; Maeng, Michael, MD, PhD; Mintz, Gary S., MD; Christiansen, Evald Hoej, MD, PhD; Hansen, Knud Noerregaard, MD; Galloe, Anders, MD, PhD; Kelbaek, Henning, MD, DMSci; Lassen, Jens Flensted, MD, PhD; Thuesen, Leif, MD, DMSci; Thayssen, Per, MD, DMSci
The American journal of cardiology, 04/2009, Volume: 103, Issue: 8Journal Article
Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston Scientific, Maple Grove, Minnesota) stents in diabetic patients. Seventy-four diabetic patients were randomly assigned to Cypher or Taxus stent implantation. Intravascular ultrasound of 5-mm long segments immediately proximal and distal to the stent was performed after the procedure and at the 8-month follow-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 ± 132.6 to 309.5 ± 146.8 mm3 ) than in the Cypher group (274.4 ± 137.2 to 275.4 ± 140.1 mm3 ; p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 ± 73.7 to 166.1 ± 85.1 mm3 ), but was unchanged in the Cypher group (153.5 ± 75.5 to 151.5 ± 75.8 mm3 ; p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 ± 3.6 to 5.8 ± 3.7 mm2 ; p = 0.097; proximal, 8.1 ± 2.7 to 8.7 ± 2.9 mm2 ; p = 0.006) without remodeling (change in EEM) in the Taxus group. Conversely, there were no significant changes in reference-segment EEM or plaque areas in the Cypher group. In conclusion, in diabetic patients, Taxus stent implantation was associated with increased (1) peri-stent EEM volume and peri-stent plaque, and (2) stent edge plaque progression accompanied by lumen reduction without remodeling. These findings were not seen in Cypher stents.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.