E-resources
-
Haverich, Axel, MD; Wahlers, Thorsten C., MD, PhD; Borger, Michael A., MD, PhD; Shrestha, Malakh, MBBS, PhD; Kocher, Alfred A., MD; Walther, Thomas, MD, PhD; Roth, Matthias, MD; Misfeld, Martin, MD; Mohr, Friedrich W., MD, PhD; Kempfert, Joerg, MD; Dohmen, Pascal M., MD, PhD; Schmitz, Christoph, MD; Rahmanian, Parwis, MD; Wiedemann, Dominik, MD; Duhay, Francis G., MD; Laufer, Günther, MD
The Journal of thoracic and cardiovascular surgery, 12/2014, Volume: 148, Issue: 6Journal Article
Objective Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. Methods In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. Results The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% ( P < .0001) and at 3 years by 16% ( P < .0001) compared with at discharge. The prevalence of severe patient-prosthesis mismatch was 3% at discharge and remained stable during the follow-up period. Conclusions In a large series of elderly patients with symptomatic severe aortic stenosis, rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status.
Author
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.