Primerjava preddvorno-prekatne in sinhrone prekatne elektrostimulacije srca pri bolnikih s stalnimi srčnimi spodbujevalniki = Comparison of dual chamber pacing and single lead VDD pacing in patients with permanent pacemakerŽižek, David, 1980- ...VDD pacing systems are an alternative to DDD pacing systems in patients with atrioventricular (AV) block and normal sinus node function. Our study comparedatrial sensing, ventricular stimulation ... threshold, AV synchrony, ventricular lead impedance and quality of life in patients with VDD and DDD pacing systems. It was assumed that there are differences concerning electrostimulation and hemodynamic support between VDD and DDD pacing systems.Ninety-six patients with implanted VDD or DDD pacing systems were enrolled prospectively into our study in 2000. The obtained data was statistically analysed using Student's t-test for independent samples or Mann-Whitney's t-test for two independent samples. Atrial sensing was significantly lower with the VDD system compared to the DDD system, at implantation and at present evaluation (p < 0.001). The ventricular pacing threshold for the VDD system at implantation was significantly lower than for the DDD system (p < 0.02). At the present evaluation, there was no significantdifference between VDD and DDD systems (p = 0.49). AV synchrony wasstatistically lower with VDD systems compared to DDD systems (p < 0.001). The difference between the values of ventricular lead impedance at implantation and at the present evaluation was significantly lower for VDD systems compared to DDD systems (p < 0.001). The quality of life did not differ significantly between VDD and DDD pacing systems (p = 0.96). VDD pacingsystems are reliable and safe concerning electrostimulation. However, hemodynamic support is better with DDD pacing systems.Vir: Medicinski razgledi : [medicinski pregledni, strokovni in raziskovalni članki]. - ISSN 0025-8121 (Letn. 43, št. 1, marec 2004, str. 19-31)Vrsta gradiva - članek, sestavni delLeto - 2004Jezik - slovenskiCOBISS.SI-ID - 18189017
Avtor
Žižek, David, 1980- |
Lipar, Luka, dr. med. |
Zupan, Igor, 1961- |
Gabrijelčič, Tone
Teme
Heart Block |
Cardiac Pacing, Artificial |
Methods |
Pacemaker, Artificial |
Perception |
Sensory Thresholds |
Electric Impedance |
Heart Atrium |
Heart Ventricle |
Quality Of Life |
Srce, blok |
Srčni spodbujevalec |
Srčno vzpodbujanje, umetno |
Zaznava |
Čutni prag |
Električna impedanca |
Kvaliteta življenja |
Srce, predvor |
Srčni prekat
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Žižek, David, 1980- | 39629 |
Lipar, Luka, dr. med. | 57223 |
Zupan, Igor, 1961- | 10726 |
Gabrijelčič, Tone | 02260 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.