-
A comparison of respiratory patterns in healthy term infants placed in car safety seats and bedsKornhauser-Cerar, Lilijana, 1958- ...Objective: The purpose of this work was to compare the incidence of apnea, hypopnea, bradycardia, or oxygen desaturation in healthy term newborns placed in hospital cribs, infant car safety beds, or ... infant car safety seats. Methods: A consecutive series of 200 newborns was recruited on the second day of life. Each subject was studied while placed in the hospital crib (30 minutes), car bed (60 minutes), and car seat (60 minutes). Physiologic data, including oxygen saturation, frequency, and type of apnea, hypopnea, and bradycardia were obtained and analyzed in a blinded manner. Results: The mean oxygen saturation level was significantly different among all of the positions(97.9% for the hospital crib, 96.3% for the car bed, and 95.7% for the car seat; P < .001). The mean minimal oxygen saturation level was lower while in both safety devices (83.7% for the car bed and 83.6% for the car seat) compared with in the hospital crib (87.4%) (P < .001). The mean total time spent with an oxygen saturation level of <95% was significantly higher (P= .003) in both safety devices (car seat: 23.9%; car bed: 17.2%) when compared with the hospital crib (6.5%). A second study of 50 subjects in whicheach infant was placed in each position for 120 minutes yielded similar results. Conclusions: In healthy term newborns, significant desaturations wereobserved in both car beds and car seats as compared with hospital cribs. This study was limited by lack of documentation of sleep stage. Therefore, these safety devices should only be used for protection during travel and not as replacements for cribs.Vir: Pediatrics. - ISSN 0031-4005 (Letn. 124, št. 3, 2009, str. 396-402)Vrsta gradiva - članek, sestavni delLeto - 2009Jezik - angleškiCOBISS.SI-ID - 26146521
Avtor
Kornhauser-Cerar, Lilijana, 1958- |
Scirica, Christina V. |
Štucin Gantar, Irena, pediatrija, 1968- |
Osredkar, Damjan |
Neubauer, David |
Kinane, Thomas Bernard
Teme
Infant Equipment |
Seat Belts |
Apnea |
Bradycardia |
Heart Rate |
Oximetry |
Hypoventilation |
Electrocardiography |
Infant, Newborn |
Prospective Studies |
Apneja |
Bradikardija |
Srčna frekvenca |
Varnostni pasovi |
Dojenček, oprema |
Prospektivne študije |
Hipoventilacija |
Oksimetrija |
Novorojenček |
Elektrokardiografija
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Kornhauser-Cerar, Lilijana, 1958- | 12176 |
Scirica, Christina V. | |
Štucin Gantar, Irena, pediatrija, 1968- | 15150 |
Osredkar, Damjan | 21413 |
Neubauer, David | 09180 |
Kinane, Thomas Bernard |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.