-
Analiza topografije papile vidnega živca pri zdravih osebah s Heidelbergovim tomografom mrežnice in z analizatorjem debeline mrežnice = Optic nerve head topography analysis in healthy adults using Heidelberg retina tomograph and retinal thickness analyzerRekič, AndrejaOptic nerve head topography analysis using the Heidelberg retina tomograph I (HRT) and the Retinal thickness analyzer (RTA) is important in the early diagnosis and follow up of glaucoma. The aims of ... our research were to obtain our own database for optic disc topography parameters in normal eyes using HRTand RTA, and assess reproducibility of measurements and clinical agreement between both devices. 50 healthy volunteers underwent HRT and RTA examinationsof both eyes. To determine reproducibility of measurements 10 volunteers repea ted the examinations of left eyes after a week. Differences between measurements by HRT and RTA were tested for statistical significance. Clinical agreement was assessed with limits of agreement and reproducibility with repeatability coefficient and intraclass correlation coefficient (ICC). Statistically significant differences (p < 0.05) between measurements by HRT and RTA were observed for all parameters, except for rim area (p = 0.051) and height variation contour (p = 0.054). Limits of agreement were wide and clinically important. Repeatability coefficient was good (< 0.10) for all parameters measured by HRT, except for retinal nerve fibre layer (RNFL) cross-sectional area (0.28). Repeatability coefficient was > 0.10 for cup area(0.15), rim area (0.19), maximum cup depth (0.13), height variation contour (0.11), and RNFL cross-sectional area (0.14) measured by RTA. ICC was good (> 90%) for most parameters, except for mean RNFL thickness (89%) measured by HRT and height variation contour (84%) measured by RTA. The two devices cannot be used interchangeably in clinical practice. At present, clinical usefulness of HRT is superior to RTA.Vir: Medicinski razgledi : [medicinski pregledni, strokovni in raziskovalni članki]. - ISSN 0025-8121 (Letn. 44, št. 4, dec. 2005, str. 397-407)Vrsta gradiva - članek, sestavni delLeto - 2005Jezik - slovenskiCOBISS.SI-ID - 20679129
Avtor
Rekič, Andreja
Teme
Retina |
Anatomy And Histology |
Optic Disk |
Tomography |
Middle Age |
Aged |
Mrežnica |
Optični disk |
Tomografija |
Srednja leta |
Starostniki |
oftalmologija |
mrežnica |
oko |
anatomija |
histologija
vir: Medicinski razgledi : [medicinski pregledni, strokovni in raziskovalni članki]. - ISSN 0025-8121 (Letn. 44, št. 4, dec. 2005, str. 397-407)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Rekič, Andreja |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi