Deployment of the deep-sea neutrino telescope Baikal-GVD continues in Lake Baikal. By April 2022, ten telescope clusters, which include 2880 optical modules, were put into operation. One of the ...urgent tasks of the Baikal project is to study the possibility of increasing the detection efficiency of the detector based on the experience of its operation and the results obtained with other neutrino telescopes in recent years. In this paper, the authors consider a variant of optimizing the telescope configuration by installing an additional string of optical modules between the detector clusters (external string). An experimental version of the external garland was installed in Lake Baikal in April 2022. The paper presents the results from calculations of the efficiency of registration of neutrino events for a new setup configuration, the technical implementation of the system for recording and collecting data from the external garland, and the first results of its full-scale tests in Lake Baikal.
Display omitted
•Detection of the key hormone cortisol using Au nanoparticles functionalized with cortisol-selective aptamers.•Assays performed within physiological concentration of cortisol in sweat ...(∼10-100 ng/mL) have an LOD of ∼1 ng/mL (∼2.7 nM).•Lateral flow assay for cortisol detection using aptamer-conjugated AuNPs has been demonstrated, indicating potential as a convenient and low cost POC sweat-based sensor for cortisol and other stress biomarkers.
A new aptamer-based lateral flow strip assay has been designed and developed for on-site rapid detection of cortisol in sweat. Cortisol in sweat has been identified as a key biomarker to monitor physiological stress. A highly sensitive and specific cortisol sensor was achieved by conjugating cortisol-selective aptamers to the surface of gold nanoparticles (AuNPs). Aptamer-functionalized AuNPs are stable against salt-induced aggregation. When cortisol molecules are present in the sample, they interact with the designed aptamers causing their desorption from the AuNP surface. Free AuNPs can then be captured by reaction with cysteamine immobilized on the test zone of the lateral flow test strip. This enables the visual detection of cortisol within minutes. Important parameters that affect the detection sensitivity in both solution and lateral flow assays, such as the loading density of aptamers per AuNP, salt and cysteamine concentrations, were investigated to provide the optimum assay performance. This hand-held device successfully exhibited a visual limit of detection of 1 ng/mL, readily covering the normal range of free cortisol in sweat (8–140 ng/mL). No significant cross reactivity to other stress biomarkers was observed. The advantages of this paper-based biosensor over previously reported test strips include the use of aptamers (which are more stable, simpler to use and lower cost than antibodies) and a simplified lateral flow assay (LFA) strip design (without the use of complementary aptamers in the test line). The resulting LFA aptasensor provides a rapid, sensitive, user-friendly and cost-effective point of care device for cortisol detection in sweat and other biofluids.
The formation of fibers by electrospinning has experienced explosive growth in the past decade, recently reaching 4,000 publications and 1,500 patents per year. This impressive growth of interest is ...due to the ability to form fibers with a variety of materials, which lend themselves to a large and rapidly expanding set of applications. In particular, coaxial electrospinning, which forms fibers with multiple core−sheath layers from different materials in a single step, enables the combination of properties in a single fiber that are not found in nature in a single material. This article is a detailed review of coaxial electrospinning: basic mechanisms, early history and current status, and an in‐depth discussion of various applications (biomedical, environmental, sensors, energy, catalysis, textiles). We aim to provide readers who are currently involved in certain aspects of coaxial electrospinning research an appreciation of other applications and of current results.
Mix and match: In this Review, the basic operation of conventional electrospinning for the formation of homogenous fibers is briefly discussed and then coaxial electrospinning and process parameters for the formation of complex core‐sheath fibers are described. Early breakthroughs in coaxial electrospinning are introduced and then recent results are reviewed in some detail regarding the formation and properties of coaxial fibers for several key application areas: biomedical, sensors, textiles, energy, and catalysis.
A lateral flow assay using DNA aptamer-based sensing for the detection of dopamine in urine is reported. Dopamine duplex aptamers (hybridized sensor with capture probe) are conjugated to 40-nm Au ...nanoparticles (AuNPs) with 20T linkers. The detection method is based on the dissociation of the duplex aptamer in the presence of dopamine, with the sensor part undergoing conformational changes and being released from the capture part. Hybridization between the complementary DNA in the test line and the conjugated AuNP-capture DNA produces a red band, whose intensity is related to the dopamine concentration. The minimum detectable concentration obtained by ImageJ analysis was <10 ng/mL (65.2 nM), while the visual limit of detection is estimated to be ~50 ng/mL (normal range of dopamine in urine of 52–480 ng/mL or 0.3–3.13 μM). No cross reactivity to other stress biomarkers in urine was confirmed. These results indicate that this robust and user-friendly point-of-care biosensor has significant potential for providing a cost-effective alternative for dopamine detection in urine.
Display omitted
•Dopamine is critical biomarker for determining stress level of individuals.•Dopamine level disturbance linked to neurodegenerative disease (Parkinson's, etc.)•Simple and low-cost point-of-care detection and measurement of dopamine levels.•Lateral flow assay using DNA aptamer-based dopamine detection.
When knowledge has advanced to a state that includes a predictive understanding of the relationship between genome sequence and organism phenotype it will be possible for future engineers to design ...and produce synthetic organisms. However, the possibility of synthetic biology does not necessarily guarantee its feasibility, in much the same way that the possibility of a brute force attack fails to ensure the timely breaking of robust encryption. The size and range of natural genomes, from a few million base pairs for bacteria to over 100 billion base pairs for some plants, suggests it is necessary to evaluate the practical limits of designing genomes of similar complexity. This analysis characterizes the complexity of natural genomes, compares them to existing engineering benchmarks, and shows that existing large software programs are on similar scale with the genome of complex natural organisms.
Control of surface wetting properties to produce strongly hydrophobic or hydrophilic effects is at the heart of many macro- and microfluidic applications. In this work, we have investigated coaxial ...electrospinning to produce core−sheath-structured nano/microfibers that combine different properties from individual core and sheath materials. Teflon AF is an amorphous fluoropolymer that is widely utilized as a hydrophobic material. Hydrophobic fluoropolymers are normally not electrospinnable because their low dielectric constant prevents sufficient charging for a solution to be electrospun. The first Teflon electrospun fibers are reported using coaxial electrospinning with Teflon AF sheath and poly(ε-caprolactone) (PCL) core materials. Using these core/sheath fibers, superhydrophobic and oleophobic membranes have been successfully produced. These coaxial fibers also preserve the core material properties as demonstrated with mechanical tensile tests. The fact that a normally nonelectrospinnable material such as Teflon AF has been successfully electrospun when combined with an electrospinnable core material indicates the potential of coaxial electrospinning to provide a new degree of freedom in terms of material combinations for many applications.
A novel dual drug delivery system is presented using triaxial structured nanofibers, which provides different release profiles for model drugs separately loaded in either the sheath or the core of ...the fiber. Homogenous, coaxial and triaxial fibers containing a combination of materials (PCL, polycaprolactone; PVP, polyvinylpyrrolidone) were fabricated. The drug release profiles were simulated using two color dyes (KAB, keyacid blue; KAU, keyacid uranine), whose release in physiological solution was measured using optical absorption as a function of time. To reach the level of 80% release of encapsulated dye from core, triaxial fibers with a PCL intermediate layer exhibited a ∼24× slower release than that from coaxial fibers. At the same time, the hygroscopic sheath layer of the triaxial fibers provided an initial burst release (∼ 80% within an hour) of a second dye as high as that from conventional single and coaxial fibers. The triaxial fiber membrane provides both a quick release from the outer sheath layer for short-term treatment and a sustained release from the fiber core for long-term treatment. The intermediate layer between inner core and outer sheath acts as a barrier to prevent leaching from the core, which can be especially important when the membranes are used in wet application. The formation of tri/multiaxially electrospun nanofibrous membranes will be greatly beneficial for biomedical applications by enabling different release profiles of two different drugs from a membrane.
Hormones produced by glands in the endocrine system and neurotransmitters produced by the nervous system control many bodily functions. The concentrations of these molecules in the body are an ...indication of its state, hence the use of the term biomarker. Excess concentrations of biomarkers, such as cortisol, serotonin, epinephrine, and dopamine, are released by the body in response to a variety of conditions, for example, emotional state (euphoria, stress) and disease. The development of simple, low-cost modalities for point-of-use (PoU) measurements of biomarkers levels in various bodily fluids (blood, urine, sweat, saliva) as opposed to conventional hospital or lab settings is receiving increasing attention. This paper starts with a review of the basic properties of 12 primary stress-induced biomarkers: origin in the body (i.e., if they are produced as hormones, neurotransmitters, or both), chemical composition, molecular weight (small/medium size molecules and polymers, ranging from ∼100 Da to ∼100 kDa), and hydro- or lipophilic nature. Next is presented a detailed review of the published literature regarding the concentration of these biomarkers found in several bodily fluids that can serve as the medium for determination of the condition of the subject: blood, urine, saliva, sweat, and, to a lesser degree, interstitial tissue fluid. The concentration of various biomarkers in most fluids covers a range of 5–6 orders of magnitude, from hundreds of nanograms per milliliter (∼1 μM) down to a few picograms per milliliter (sub-1 pM). Mechanisms and materials for point-of-use biomarker sensors are summarized, and key properties are reviewed. Next, selected methods for detecting these biomarkers are reviewed, including antibody- and aptamer-based colorimetric assays and electrochemical and optical detection. Illustrative examples from the literature are discussed for each key sensor approach. Finally, the review outlines key challenges of the field and provides a look ahead to future prospects.
A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LFA) device for point-of-care (POC) and self-monitoring screening is reported. The device ...utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent coagulation. CaCl2 solutions of varying concentrations are added to citrated blood, producing Ca(2+) ions to re-establish the coagulation cascade and mimic different blood coagulation abilities in vitro. Blood samples are dispensed into a paper-based LFA device consisting of sample pad, analytical membrane and wicking pad. The porous nature of the cellulose membrane separates the aqueous plasma component from the large blood cells. Since the viscosity of blood changes with its coagulation ability, the distance RBCs travel in the membrane in a given time can be related to the blood clotting time. The distance of the RBC front is found to decrease linearly with increasing CaCl2 concentration, with a travel rate decreasing from 3.25 mm min(-1) for no added CaCl2 to 2.2 mm min(-1) for 500 mM solution. Compared to conventional plasma clotting analyzers, the LFA device is much simpler and it provides a significantly larger linear range of measurement. Using the red colour of RBCs as a visible marker, this approach can be utilized to produce a simple and clear indicator of whether the blood condition is within the appropriate range for the patient's condition.