We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS ...HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A ...background model is constructed using GEANT4 to simulate the surface-event background from super(210)Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
This case report covers the case of a 56-year-old woman with two separate occurrences of squamous cell neoplasms, one arising in pink tattoo pigment and another arising in orange tattoo pigment. A ...review of the literature was conducted to evaluate the prevalence of malignancy occurring in tattoos. This is rare and there are a limited number of case reports and no large studies done on this condition. Most malignancies in tattoos occur in red, black, or blue tattoo inks and no cases have been reported thus far of malignancy in pink or orange tattoo pigments. Due to the limited number of cases, more case studies are needed to determine the prevalence, risk, and epidemiology of malignancy arising within tattoos.
Hidradenitis suppurativa (HS) is a multifactorial disease involving the skin and subcutaneous tissues characterized by deep-seated, painful nodules and abscesses with draining sinus tracts. It ...affects mostly younger individuals between the ages of 18 and 34. The discomfort and embarrassment that patients affected by HS experience negatively impact their daily lives. It is associated with decreased quality of life and high rates of comorbid depression and anxiety. The rate of depression in HS was reported to be as high as 26%. Its pathogenesis is multifactorial and as such requires a multimodal approach to treatment, which subsequently is reviewed here. Moreover, the pathogenesis of HS is complex and only partially understood. Autoinflammation is the key driver of disease development and is linked with dysregulated inflammasome activation with the subsequent production of inflammatory cytokines. Genetics and cutaneous microbiome play a role in the development of chronic inflammation and lesion formation. Risk factors such as obesity, metabolic syndrome, diabetes, and smoking also add to the systemic inflammation. Targeting these risk factors is a key aspect of the treatment of HS. Lifestyle modifications are used in conjunction with pharmacotherapy and procedures to effectively manage the disease.
The SuperCDMS experiment aims to directly detect dark matter particles called WIMPs (weakly interacting massive particles). The detectors measure phonon and ionization energy due to nuclear and ...electron recoils from incident particles. The SuperCDMS Detector Monte Carlo group uses Geant4 to simulate electron-hole pairs (
e
-
/
h
+
) and low temperature phonons. We use these simulations in order to study energy deposition in the detectors. Phonons and electron-hole pairs are tracked in a crystal detector. Because of the band structure of the crystals, the electrons undergo oblique propagation. The charge electrodes on each side of the detector are biased at different voltages while the phonon sensors are grounded. This creates a nearly uniform electric field through the bulk of the detector, with a complex shape near the surfaces. The electric field is calculated from interpolating on a tetrahedral mesh. The resulting TES phonon readout, as well as the FET charge readout are simulated. To calculate the FET readout, the Shockley-Ramo theorem is applied to simulate the current in the FET. The goal of this paper is to describe the theory and implementation of calculating the electric field, performing the charge carrier propagation, and simulating the FET readout of the SuperCDMS detectors.
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤10 GeV/c2) that may constitute dark matter by using cryogenic detectors of two types ...(HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ∼1×10−43 cm2 for a dark matter particle mass of 1 GeV/c2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H3 and naturally occurring Si32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground ...Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses <10 GeV/c2. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eVee (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ∼9 eVee at 0 keV to 101 eVee at ∼10 keVee. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/c2. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses ≲3 GeV/c2.
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has ...achieved a low energy threshold with improved sensitivity to low-mass ( < 10 GeV / c 2 ) dark matter particles. We present an analysis of the final CDMSlite dataset, taken with a different detector than was used for the two previous CDMSlite datasets. This analysis includes a data “salting” method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV / c 2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4 × 10 − 42 cm 2 at 5 GeV / c 2 , a factor of ~ 2.5 improvement over the previous CDMSlite result.
G4CMP: Condensed matter physics simulation using the Geant4 toolkit Kelsey, M.H.; Agnese, R.; Alam, Y.F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
October 2023, 2023-10-00, Letnik:
1055
Journal Article
Recenzirano
G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as ...electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.