Background
Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which ...combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy.
Materials and methods
In the porcine model (
n
= 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO
2
), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed.
Results
After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08;
p
= 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L;
p
= 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML.
Conclusions
HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.
Background
Fluorescence-based enhanced reality (FLER) is a computer-based quantification method of fluorescence angiographies to evaluate bowel perfusion. The aim of this prospective trial was to ...assess the clinical feasibility and to correlate FLER with metabolic markers of perfusion, during colorectal resections.
Methods
FLER analysis and visualization was performed in 22 patients (diverticulitis
n
= 17; colorectal cancer
n
= 5) intra- and extra-abdominally during distal and proximal resection, respectively. The fluorescence signal of indocyanine green (0.2 mg/kg) was captured using a near-infrared camera and computed to create a virtual color-coded cartography. This was overlaid onto the bowel (enhanced reality). It helped to identify regions of interest (ROIs) where samples were subsequently obtained. Resections were performed strictly guided according to clinical decision. On the surgical specimen, samplings were made at different ROIs to measure intestinal lactates (mmol/L) and mitochondria efficiency as acceptor control ratio (ACR).
Results
The native (unquantified) fluorescent signal diffused to obvious ischemic areas during the distal appreciation. Proximally, a lower diffusion of ICG was observed. Five anastomotic complications occurred. The expected values of local capillary lactates were correlated with the measured values both proximally (3.62 ± 2.48 expected vs. 3.17 ± 2.8 actual; rho 0.89;
p
= 0.0006) and distally (4.5 ± 3 expected vs. 4 ± 2.5 actual; rho 0.73;
p
= 0.0021). FLER values correlated with ACR at the proximal site (rho 0.76;
p
= 0.04) and at the ischemic zone (rho 0.71;
p
= 0.01). In complicated cases, lactates at the proximal resection site were higher (5.8 ± 4.5) as opposed to uncomplicated cases (2.45 ± 1.5;
p
= 0.008). ACR was reduced proximally in complicated (1.3 ± 0.18) vs. uncomplicated cases (1.68 ± 0.3;
p
= 0.023).
Conclusions
FLER allows to image the quantified fluorescence signal in augmented reality and provides a reproducible estimation of bowel perfusion (NCT02626091).
Purpose
We address the automatic segmentation of healthy and cancerous liver tissues (parenchyma, active and necrotic parts of hepatocellular carcinoma (HCC) tumor) on multiphase CT images using a ...deep learning approach.
Methods
We devise a cascaded convolutional neural network based on the
U
-Net architecture. Two strategies for dealing with multiphase information are compared: Single-phase images are concatenated in a multi-dimensional features map on the input layer, or output maps are computed independently for each phase before being merged to produce the final segmentation. Each network of the cascade is specialized in the segmentation of a specific tissue. The performances of these networks taken separately and of the cascaded architecture are assessed on both single-phase and on multiphase images.
Results
In terms of Dice coefficients, the proposed method is on par with a state-of-the-art method designed for automatic MR image segmentation and outperforms previously used technique for interactive CT image segmentation. We validate the hypothesis that several cascaded specialized networks have a higher prediction accuracy than a single network addressing all tasks simultaneously. Although the portal venous phase alone seems to provide sufficient contrast for discriminating tumors from healthy parenchyma, the multiphase information brings significant improvement for the segmentation of cancerous tissues (active versus necrotic part).
Conclusion
The proposed cascaded multiphase architecture showed promising performances for the automatic segmentation of liver tissues, allowing to reliably estimate the necrosis rate, a valuable imaging biomarker of the clinical outcome.
Introduction
Near-infrared fluorescence cholangiography (NIRF-C) is a popular application of fluorescence image-guided surgery (FIGS). NIRF-C requires near-infrared optimized laparoscopes and the ...injection of a fluorophore, most frequently Indocyanine Green (ICG), to highlight the biliary anatomy. It is investigated as a tool to increase safety during cholecystectomy. The European registry on FIGS (EURO-FIGS:
www.euro-figs.eu
) aims to obtain a snapshot of the current practices of FIGS across Europe. Data on NIRF-C are presented.
Methods
EURO-FIGS is a secured online database which collects anonymized data on surgical procedures performed using FIGS. Data collected for NIRF-C include gender, age, Body Mass Index (BMI), pathology, NIR device, ICG dose, ICG timing of administration before intraoperative visualization, visualization (Y/N) of biliary structures such as the cystic duct (CD), the common bile duct (CBD), the CD-CBD junction, the common hepatic duct (CHD), Visualization scores, adverse reactions to ICG, operative time, and surgical complications.
Results
Fifteen surgeons (12 European surgical centers) uploaded 314 cases of NIRF-C during cholecystectomy (cholelithiasis
n
= 249, cholecystitis
n
= 58, polyps
n
= 7), using 4 different NIR devices. ICG doses (mg/kg) varied largely (mean 0.28 ± 0.17, median 0.3, range: 0.02–0.62). Similarly, injection-to-visualization timing (minutes) varied largely (mean 217 ± 357; median 57), ranging from 1 min (direct intragallbladder injection in 2 cases) to 3120 min (
n
= 2 cases). Visualization scores before dissection were significantly correlated, at univariate analysis, with ICG timing (all structures), ICG dose (CD-CBD), device (CD and CD-CBD), surgeon (CD and CD-CBD), and pathology (CD and CD-CBD). BMI was not correlated. At multivariate analysis, pathology and timing remained significant factors affecting the visualization scores of all three structures, whereas ICG dose remained correlated with HD visualization only.
Conclusions
The EURO-FIGS registry has confirmed a wide disparity in ICG dose and timing in NIRF-C. EURO-FIGS can represent a valuable tool to promote and monitor FIGS-related educational and consensus activities in Europe.
Radiomics is an emerging field which extracts quantitative radiology data from medical images and explores their correlation with clinical outcomes in a non-invasive manner. This review aims to ...assess whether radiomics is a useful and reproducible method for clinical management of hepatocellular carcinoma (HCC) by reviewing the strengths and weaknesses of current radiomics literature pertaining specifically to HCC. From an initial set of 48 articles recovered through database searches, 23 articles were retained to be included in this review after full screening. Among these 23 studies, 7 used a radiomics approach in magnetic resonance imaging (MRI). Only two studies applied radiomics to positron emission tomography–computed tomography (PET–CT). In the remaining 14 articles, a radiomics analysis was performed on computed tomography (CT). Eight studies dealt with the relationship between biological signatures and imaging findings, and can be classified as radiogenomic studies. For each study included in our review, we computed a Radiomics Quality Score (RQS) as proposed by Lambin et al. We found that the RQS (mean ± standard deviation) was 8.35 ± 5.38 (out of a possible maximum value of 36). Although these scores are fairly low, and radiomics has not yet reached clinical utility in HCC, it is important to underscore the fact that these early studies pave the way for the radiomics field with a focus on HCC. Radiomics is still a very young field, and is far from being mature, but it remains a very promising technology for the future for developing adequate personalized treatment as a non-invasive approach, for complementing or replacing tumor biopsies, as well as for developing novel prognostic biomarkers in HCC patients.
Background
HSI is an optical technology allowing for a real-time, contrast-free snapshot of physiological tissue properties, including oxygenation. Hyperspectral imaging (HSI) has the potential to ...quantify the gastrointestinal perfusion intraoperatively. This experimental study evaluates the accuracy of HSI, in order to quantify bowel perfusion, and to obtain a superposition of the hyperspectral information onto real-time images.
Methods
In 6 pigs, 4 ischemic bowel loops were created (A, B, C, D) and imaged at set time points (from 5 to 360 min). A commercially available HSI system provided pseudo-color maps of the perfusion status (StO2, Near-InfraRed perfusion) and the tissue water index. An ad hoc software was developed to superimpose HSI information onto the live video, creating the HYPerspectral-based Enhanced Reality (HYPER). Seven regions of interest (ROIs) were identified in each bowel loop according to StO2 ranges, i.e., vascular (VASC proximal and distal), marginal vascular (MV proximal and distal), marginal ischemic (MI proximal and distal), and ischemic (ISCH). Local capillary lactates (LCL), reactive oxygen species (ROS), and histopathology were measured at the ROIs. A machine-learning-based prediction algorithm of LCL, based on the HSI-StO2%, was trained in the 6 pigs and tested on 5 additional animals.
Results
HSI parameters (StO2 and NIR) were congruent with LCL levels, ROS production, and histopathology damage scores at the ROIs discriminated by HYPER. The global mean error of LCL prediction was 1.18 ± 1.35 mmol/L. For StO2 values > 30%, the mean error was 0.3 ± 0.33.
Conclusions
HYPER imaging could precisely quantify the overtime perfusion changes in this bowel ischemia model.
Background
Indocyanine green fluorescence imaging (ICG-FI) can be used to evaluate intestinal perfusion prior to anastomosis. Several software for the quantification of fluorescence have emerged, but ...these have not previously been compared. The aim of this study was to compare the results from quantitative ICG-FI analysis of relative perfusion in an experimental setting using two different software-based quantification algorithms (FLER and Q-ICG).
Methods
Twenty pigs received a laparotomy, and ischemic areas were created in three segments of the small intestine of each pig. For each ischemic area, fluorescence imaging was performed and the fluorescence recordings were quantitatively analyzed using FLER and Q-ICG. The quantitative analysis resulted in a set of perfusion lines for each software for either 30%, 60% or 100% relative perfusion. The perfusion lines were compared by registering the normalized slope for each set of perfusion lines, calculating the relative perfusion percentage in the FLER perfusion line according to Q-ICG, and measuring the length of the ischemic area for each analysis.
Results
Fifty-four fluorescence recordings from 18 pigs were included. The ischemic segment for FLER was significantly longer in the 30% perfusion group and significantly shorter in the 100% perfusion group as compared to Q-ICG. The normalized slope for the FLER perfusion lines was significantly higher in the 30% perfusion group and significantly lower in the 100% perfusion group as compared to the Q-ICG perfusion lines. For the perfusion lines defined by FLER as 30%, 60%, and 100%, Q-ICG found 35.2% (
p
= 0.07), 63.7% (
p
= 0.31), and 84.1% perfusion (
p
= 0.003) respectively.
Conclusion
The two software demonstrated significant differences in quantitative fluorescence analysis when perfusion was either very high or very low. The clinical relevance of these differences is unclear.
Background
Colorectal surgery has benefited from advances in precision medicine such as total mesorectal resection, and recently, mesocolon resection, fluorescent perfusion imaging, and fluorescent ...node mapping. However, these advances fail to address the variable quality of mesocolon dissection and the directed extent of vascular dissection (including high ligation) or pre-resection anastomotic perfusion mapping, thereby impacting anastomotic leaks. We propose a new paradigm of precision image-directed colorectal surgery involving 3D preoperative resection modeling and intraoperative fluoroscopic and fluorescence vascular imaging which better defines optimal dissection planes and vascular vs. anatomy-based resection lines according to our hypothesis.
Methods
Six pigs had preoperative CT with vascular 3D reconstruction allowing for the preoperative planning of vascular-based dissection. Laparoscopic surgery was performed in a hybrid operating room (OR). Superselective arterial catheterization was performed in branches of the superior mesenteric artery (SMA) or the inferior mesenteric artery (IMA). Intraoperative boluses of 0.1 mg/kg or a continuous infusion of indocyanine green (ICG) (0.01 mg/mL) were administered to guide fluorescent-based sigmoid and ileocecal resections. Fluorescence was assessed using proprietary software at several regions of interest (ROI) in the right and left colon.
Results
The approach was feasible and safe. Selective catheterization took an average of 43 min. Both bolus and continuous perfusion clearly marked pre-identified vessels (arteries/veins) and the target colon segment, facilitating precise resections based on the visible vascular anatomy. Quantitative software analysis indicated the optimal resection margin for each ROI.
Conclusion
Intra-arterial fluorescent mapping allows visualization of major vascular structures and segmental colonic perfusion. This may help to prevent any inadvertent injury to major vascular structures and to precisely determine perfusion-based resection planes and margins. This could enable tailoring of the amount of colon resected, ensure good anastomotic perfusion, and improve oncological outcomes.
Introduction/objective
Gastric conduit (GC) is used for reconstruction after esophagectomy. Anastomotic leakage (AL) incidence remains high, given the extensive disruption of the gastric circulation. ...Currently, there is no reliable method to intraoperatively quantify gastric perfusion. Hyperspectral imaging (HSI) has shown its potential to quantify serosal StO
2
. Confocal laser endomicroscopy (CLE) allows for automatic mucosal microcirculation quantification as functional capillary density area (FCD-A). The aim of this study was to quantify serosal and mucosal GC’s microperfusion using HSI and CLE. Local capillary lactate (LCL) served as biomarker.
Methods
GC was formed in 5 pigs and serosal StO
2
% was quantified at 3 regions of interest (ROI) using HSI: fundus (ROI-F), greater curvature (ROI-C), and pylorus (ROI-P). After intravenous injection of sodium-fluorescein (0.5 g), CLE-based mucosal microperfusion was assessed at the corresponding ROIs, and LCLs were quantified via a lactate analyzer.
Results
StO
2
and FCD-A at ROI-F (41 ± 10.6%, 3.3 ± 3.8, respectively) were significantly lower than ROI-C (68.2 ± 6.7%,
p
value: 0.005; 18.4 ± 7,
p
value: 0.01, respectively) and ROI-P (72 ± 10.4%,
p
value: 0.005; 15.7 ± 3.2
p
value: 0.001). LCL value at ROI-F (9.6 ± 4.7 mmol/L) was significantly higher than at ROI-C (2.6 ± 1.2 mmol/L,
p
value: 0.04) and ROI-P (2.6 ± 1.3 mmol/L,
p
value: 0.04). No statistically significant difference was found in all metrics between ROI-C and ROI-P. StO
2
correlated with FCD-A (Pearson’s
r
= 0.67). The LCL correlated negatively with both FCD-A (Spearman’s
r
= − 0.74) and StO
2
(Spearman’s
r
= − 0.54).
Conclusions
GC formation causes a drop in serosal and mucosal fundic perfusion. HSI and CLE correlate well and might become useful intraoperative tools.
Background
Indocyanine green fluorescence imaging (ICG-FI) may be used to visualize intestinal perfusion prior to anastomosis. Methods for quantification of the fluorescence signal are required to ...ensure an objective evaluation. The aim of this study was to evaluate a method for quantification of relative perfusion and to investigate the correlation between the perfusion level and the anastomotic strength.
Method
This blinded, randomized, experimental trial included twenty pigs. Each pig received three small intestinal anastomoses with 30%, 60%, or 100% perfusion, respectively. The perfusion levels were determined relative to healthy intestine using ICG-FI. Ischemia was induced by mesenteric ligation and the perfusion level of each anastomosis was determined using a software-based analysis of the fluorescence signal. On postoperative day 5, the anastomoses were subjected to tensile strength test and histopathological assessment.
Results
No anastomotic leakage occurred. The tensile strength of the 30% perfusion group was 9.09 N, which was significantly lower than the 60% perfusion group (11.5 N) and the 100% perfusion group (12.9 N). The difference between the 60% perfusion group and the 100% perfusion group was not significant. The histopathological assessment showed no significant differences between perfusion groups.
Conclusions
A reduction in blood supply to 30%, as determined by ICG-FI, in small intestinal anastomoses was necessary to demonstrate a decrease in tensile strength.