Background
MRI is the reference for the diagnosis of arterial cerebral ischemia, but its role in acute mesenteric ischemia (AMI) is poorly known.
Purpose
To assess MRI detection of early ischemic ...bowel lesions in a porcine model of arterial AMI.
Study Type
Prospective/cohort.
Animal Model
Porcine model of arterial AMI obtained by embolization of the superior mesenteric artery (seven pigs).
Field Strength/Sequence
A 5‐T. T1 gradient‐echo‐weighted‐imaging (WI), half‐Fourier‐acquisition‐single‐shot‐turbo‐spin‐echo, T2 turbo‐spin‐echo, true‐fast‐imaging‐with‐steady‐precession (True‐FISP), diffusion‐weighted‐echo‐planar (DWI).
Assessment
T1‐WI, T2‐WI, and DWI were performed before and continuously after embolization for 6 hours. The signal intensity (SI) of the ischemic bowel was assessed visually and quantitatively on all sequences. The apparent diffusion coefficient (ADC) was assessed.
Statistical Tests
Paired Student's t‐test or Mann–Whitney U‐test, significance at P < 0.05.
Results
One pig died from non‐AMI‐related causes. The remaining pigs underwent a median 5 h53 (range 1 h24–6 h01) of ischemia. Visually, the ischemic bowel showed signal hyperintensity on DWI‐b800 after a median 85 (57–276) minutes compared to the nonischemic bowel. DWI‐b800 SI significantly increased after 2 hours (+19%) and the ADC significant decrease within the first hour (−31%). The ischemic bowel was hyperintense on precontrast T1‐WI after a median 87 (70–171) minutes with no significant quantitative changes over time (P = 0.46–0.93). The ischemic bowel was hyperintense on T2‐WI in three pigs with a significant SI increase on True‐FISP after 1 and 2 hours.
Data Conclusion
Changes in SI and ADC can be seen early after the onset of arterial AMI with DWI. The value of T2‐WI appears to be limited.
Evidence Level
1
Technical Efficacy
Stage 2
Background
Intraoperative localization of endoluminal lesions is can be difficult during laparoscopy. Preoperative endoscopic marking is therefore necessary. Current methods include submucosal ...tattooing using visible dyes, which in case of transmural injection can impair surgical dissection. Tattooing using indocyanine green (ICG) coupled to intraoperative near-infrared (NIR) laparoscopy has been described. ICG is only visible under NIR-light, therefore, it doesn’t impair the surgical workflow under white light even if there is spillage. However, ICG tattoos have rapid diffusion and short longevity. We propose fluorescent over-the-scope clips (FOSC), using a novel biocompatible fluorescent paint, as durable lesion marking.
Methods
In six pigs, gastric and colonic endoscopic tattoos using 0.05 mg/mL of ICG and markings using the fluorescent OSC were performed (T0). Simultaneously, NIR laparoscopy was executed. Follow-up laparoscopies were conducted at postoperative day (POD) 4–6 (T1) and POD 11–12 (T2). During laparoscopy, fluorescence intensity was assessed. In one human cadaver, FOSC was used to mark a site on the stomach and on the sigmoid colon, respectively. Intraoperative detection during NIR laparoscopy was assessed.
Results
Gastric and colonic ICG tattooing and OSC markings were easily visible using NIR laparoscopy on T0. All FOSC were visible at T1 and T2 in both stomach and colon, whereas the ICG tattooing at T1 was only visible in the stomach of 2 animals and in the colon of 3 animals. At T2, tattoos were not visible in any animal. FOSC were still visible in both stomach and colon of the human cadaver at 10 days.
Conclusion
Endoscopic marking using FOSC can be an efficient and durable alternative to standard methods.
Background
Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which ...combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy.
Materials and methods
In the porcine model (
n
= 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO
2
), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed.
Results
After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08;
p
= 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L;
p
= 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML.
Conclusions
HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.
Iatrogenic ureteral injuries (IUI) occur in 0.5-1.3% of cases during abdominal surgery. If not recognized intraoperatively, IUI increase morbidity/mortality. A universally accepted method to prevent ...IUI is lacking. Near-infrared fluorescent imaging (NIRF), penetrating deeper than normal light within the tissue, might be useful, therefore ureter visualization combining NIRF with special dyes (i.e. IRDye 800BK) is promising. Aim of this work is to evaluate the detection of ureters using stents coated with a novel biocompatible fluorescent material (NICE: near-infrared coating of equipment), during laparoscopy. female pigs underwent placement of NICE-coated stents (NS). NIRF was performed, and fluorescence intensity (FI) was computed. Successively, 0.15 mg/kg of IRDye 800BK was administered intravenously, and FI was computed at different timepoints. Ureter visualization using NS only was further assessed in a human cadaver. Both methods allowed in vivo ureter visualization, with equal FI. However, NS were constantly visible whereas IRDye 800BK allowed visualization exclusively during the ureteral peristaltic phases. In the human cadaver, NS provided excellent ureter visualization in its natural anatomical position. NS provided continuous ureteral visualization with similar FI as the IRDye 800BK, which exclusively allowed intermittent visualization, dependent on ureteral peristalsis. NS might prove useful to visualize ureters intraoperatively, potentially preventing IUI.
Ureteral injury during laparoscopic surgery is rare, but when it occurs, it can be a serious problem. Near-infrared fluorescence (NIRF) with methylene blue (MB) administration is a promising ...technique for easier and potentially earlier intraoperative visualization of the ureter. Aim of this prospective study was to assess the feasibility of NIRF imaging of the ureter during laparoscopic colorectal surgery, using MB.
Patients undergoing laparoscopic colorectal surgery were included and received intravenous injection of MB preoperatively. The ureter was visualized using a laparoscope, which offered both conventional and fluorescence imaging. Intraoperative recognition of the ureter was registered. The precision of ureter distinction with MB imaging was compared to the conventional laparoscopic view.
Ten patients were included. All procedures were initially performed using a laparoscopic approach. Dose per injection ranged between 0.125 mg/kg and 1.0 mg/kg bodyweight. There were no adverse effects attributable to MB administration. The ureter was successfully detected in five patients, with highest contrast between ureter and surrounding tissue at an administered dose of 0.75-1.0 mg/kg. The fluorescent signal was only picked up after the ureter was already visible in the conventional white light mode.
Ureteral fluorescence imaging using MB proved to be safe and feasible. However, the present technique does not provide practical advantage over conventional laparoscopic imaging for identification of the ureter during laparoscopic colorectal surgery. Future research is necessary to explore more extensive dose finding, alternative fluorescent dyes, or improvement of the imaging system to make this application clinically beneficial.
Background: Intestinal resection causes inevitable vascular damage, which cannot always be seen during an intraoperative clinical assessment of local intestinal perfusion. If left unaltered, impaired ...perfusion can lead to complications, such as anastomotic leakage (AL). Therefore, we demonstrate the use of a novel laparoscopic laser speckle contrast imaging (LSCI)-based approach in order to assess local intestinal perfusion during the construction of intestinal anastomoses. Methods: Three segments were isolated from the small intestine of a pig, while the perfusion of each was compromised by coagulating 7–8 mesenteric arteries. Both clinical assessments and LSCI were used to detect the induced perfusion deficits and to subsequently guide a transection in either a well perfused, marginally perfused, or poorly perfused tissue area within the segment. Bowel ends were then utilized for the creation of three differently perfused anastomoses: well perfused/well perfused (anastomosis segment 1), well perfused/poorly perfused (anastomosis segment 2), and poorly perfused/poorly perfused (anastomosis segment 3). After construction of the anastomoses, a final perfusion assessment using both clinical assessment and LSCI was executed in order to evaluate the vascular viability of the anastomosis. Results: Laparoscopic LSCI enabled continuous assessment of local intestinal perfusion and allowed for detection of perfusion deficits in real time. The imaging feedback precisely guided the surgical procedure, and, when evaluating the final anastomotic perfusion, LSCI was able to visualize the varying degrees of perfusion, whereas standard clinical assessment yielded only minor differences in visual appearance of the tissue. Conclusions: In this technical note, we demonstrate a novel LSCI-based approach for intraoperative perfusion assessment. With its ability to continuously visualize perfusion in real time, laparoscopic LSCI has significant potential for the optimization of anastomotic surgery in the near future.
Iatrogenic ureteral injury is one of the feared complications during intrapelvic surgery. There are limited data on the use of novel near-infrared fluorescence (NIRF) imaging dyes for the purpose of ...noninvasive ureteral visualization in robot-assisted laparoscopic surgery (RALS). In this study, we evaluated the feasibility of NIRF imaging of the ureter using the IRDye
800BK dye as the fluorescence dye and a robotic platform with Firefly™ technology as an imaging system.
An intravenous dose of 0.15 mg/kg was administered in 3 pigs and NIRF imaging was performed for a total duration of 60 minutes. The intraoperative video recordings were analyzed to determine fluorescence intensities and the target-to-background ratio (TBR).
In all included animals, a clear delineation of the ureter was achieved from 5 minutes after dye administration until the end of the study. During this time period, the ureter was clearly distinguishable from its surroundings and no statistical differences in TBR were observed.
The IRDye 800BK dye, a novel NIRF dye currently undergoing clinical translation, is a promising contrast agent used for noninvasive ureteral imaging, which has the potential to be valuable during RALS.
Intraoperative indocyanine green (ICG) fluorescence angiography has gained popularity and acceptance in many surgical fields for the real-time assessment of tissue perfusion. Although vasopressors ...have the potential to preclude an accurate assessment of tissue perfusion, there is a lack of literature with regards to its effect on ICG fluorescence angiography. An experimental porcine model was used to expose the small bowel for quantitative tissue perfusion assessment. Three increasing doses of norepinephrine infusion (0.1, 0.5, and 1.0 µg/kg/min) were administered intravenously over a 25-min interval. Time-to-peak fluorescence intensity (TTP) was the primary outcome. Secondary outcomes included absolute fluorescence intensity and local capillary lactate (LCL) levels. Five large pigs (mean weight: 40.3 ± 4.24 kg) were included. There was no significant difference in mean TTP (in seconds) at baseline (4.23) as compared to the second (3.90), third (4.41), fourth (4.60), and fifth ICG assessment (5.99). As a result of ICG accumulation, the mean and the maximum absolute fluorescence intensity were significantly different as compared to the baseline assessment. There was no significant difference in LCL levels (in mmol/L) at baseline (0.74) as compared to the second (0.82), third (0.64), fourth (0.60), and fifth assessment (0.62). Increasing doses of norepinephrine infusion have no significant influence on bowel perfusion using ICG fluorescence angiography.
Anatomical liver resection (ALR) is the preferred oncological approach for the treatment of primary liver malignancies, such as hepatocellular carcinoma and intrahepatic cholangiocarcinoma. The ...demarcation line (DL) is formed by means of selective vascular occlusion and is used by surgeons to guide ALR. Emerging intraoperative technologies are playing a major role to enhance the surgeon’s vision and ensure a precise oncologic surgery. In this article, a brief overview of modalities to assess the DL during ALRs is presented, from the established conventional techniques to future perspectives.
Over the last decade fluorescence-guided surgery has been primarily focused on the NIR-I window. However, the NIR-I window has constraints, such as limited penetration and scattering. Consequently, ...exploring the performance of NIR-I dyes at longer wavelengths (i.e., the NIR-II window) is crucial to expanding its application. Two fluorophores were used in three pigs to identify the mean fluorescence intensity (MFI) using two commercially available NIR-I and NIR-II cameras. The near-infrared coating of equipment (NICE) was used to identify endoluminal surgical catheters and indocyanine green (ICG) for common bile duct (CBD) characterization. The NIR-II window evaluation showed an MFI of 0.4 arbitrary units (a.u.) ± 0.106 a.u. in small bowel NICE-coated catheters and an MFI of 0.09 a.u. ± 0.039 a.u. in gastric ones. In CBD characterization, the ICG MFI was 0.12 a.u. ± 0.027 a.u., 0.18 a.u. ± 0.100 a.u., and 0.22 a.u. ± 0.041 a.u. at 5, 35, and 65 min, respectively. This in vivo imaging evaluation of NIR-I dyes confirms its application in the NIR-II domain. To the best of our knowledge, this is the first study assessing the MIF of NICE in the NIR-II window using a commercially available system. Further comparative trials are necessary to determine the superiority of NIR-II imaging systems.