This systematic review and meta-analysis compares sodium hyaluronate (HY) with non-HY based artificial tears in the treatment of dry eye syndrome. A literature search for clinical trials comparing HY ...against non-HY preparations was conducted across PubMed, Cochrane Central Register of Controlled Trials and Scopus databases from inception up to May 2016. Majority of the 18 studies selected for review showed superiority of HY in improving ocular staining and symptoms. Randomized controlled trials (RCTs) examining Schirmer's I (SH) and tear breakup time (TBUT) underwent further meta-analyses with calculation of pooled standardized mean differences (SMDs) with 95% confidence intervals (CIs). 7 RCTs including 383 eyes randomized to HY and 596 eyes to non-HY preparations underwent meta-analysis for SH. 9 RCTs including 458 eyes randomized to HY and 651 eyes to non-HY preparations underwent meta-analysis for TBUT. By fixed-effects modelling, HY demonstrated greater improvement of SH compared to non-HY preparations (SMD, 0.238; 95% CI, 0.107 to 0.369; p < 0.001). By random-effects modelling, HY demonstrated less improvement of TBUT (SMD, -0.566; 95% CI, -1.099 to -0.0336; p = 0.037). In summary, neither preparation was shown to be consistently superior across all outcome measures. The difference in effect between preparations on SH and TBUT was not clinically significant.
Combined phacoemulsification and trabeculectomy is able to achieve greater reduction in intraocular pressure (IOP), higher rates of complete surgical success and fewer postoperative manipulations and ...visits compared with combined phacoemulsification and Xen implantation in glaucomatous eyes.
Our study aims to compare and understand the differences between the efficacy and safety of XEN45 implantation and trabeculectomy in Asian eyes with glaucoma.
This was a retrospective, single-center, comparative study of consecutive patients who underwent combined phacoemulsification and trabeculectomy (Phaco-Trab) from January 2013 to June 2014 and combined phacoemulsification and XEN45 implantation (Phaco-Xen) from May 2017 to September 2018 in a tertiary Ophthalmology center in Singapore. Outcome measures included IOP, number of anti-glaucoma eyedrops, success rate, factors leading to success/failure, number of postoperative interventions and visits required, and surgical complications.
A total of 137 eyes (91 Phaco-Trab, 46 Phaco-Xen) were included. Phaco-Trab group had greater mean IOP reduction at all time points beyond postoperative month (POM) 1 (mean difference 2.9 to 3.8 mm Hg; P<0.05), and greater reduction in mean number of antiglaucoma eyedrops beyond POM3, thought this was not statistically significant. At POM12, complete success was achieved in 83.5% in Phaco-Trab and 52.2% of Phaco-Xen group, respectively (P<0.001). There was no significant factor associated with surgical failure, other than the difference in surgical procedure. Phaco-Trab group required fewer number of postoperative interventions (P=0.009), with only a mean of 0.1 bleb interventions required per patient, versus 1.5 in Phaco-Xen group (P<0.001). Safety profiles in both groups were comparable, with no statistically significant difference in intraoperative/postoperative complications.
Phaco-Trab has significantly higher reduction in both IOP and number of antiglaucoma medications compared with Phaco-Xen group, with greater surgical success and fewer postoperative manipulations and visits. Safety profiles were comparable.
Purpose
The XEN45 Gel Stent is currently the only FDA-approved sub-conjunctival minimally invasive glaucoma surgery (MIGS) procedure. It has been used worldwide either as a standalone implantation ...procedure or in combination with phacoemulsification surgery. Concomitant phacoemulsification is understood to influence outcomes of traditional subconjunctival filtering surgery. However, the comparative efficacy between standalone XEN45 Gel Sent implantation (“Standalone XEN45”) and combined XEN-phacoemulsification surgery (“XEN45-Phaco”) remains unclear. This study aims to appraise current literature to compare the efficacy of Standalone XEN45 and XEN45-Phaco in open-angle glaucoma.
Methods
A comprehensive search of PubMed, CINAHL, CENTRAL databases was performed with the terms “Xen surgery” followed by selective vetting. Pilot, cohort, observational studies and randomised controlled trials that included at least 10 patients undergoing either Standalone XEN45 or XEN45-Phaco surgeries for the treatment of open-angle glaucoma were deemed eligible for inclusion after independent assessment by 2 authors. The search workflow was reported according to the PRISMA guidelines. Data was pooled using random-effects model. A meta-analysis of continuous outcome and proportions was performed using the
meta
routine in R v3.2.1.
Results
Ten studies were included. There was a statistically significant difference in IOP reduction favouring Standalone XEN45 at post-operative day 1, week 1, months 1, 3 and 6. There was a statistically significant difference in decrease in IOP-lowering medications favouring Standalone XEN45 at post-operative week 1 and month 1.
Conclusion
Standalone XEN45 has superior IOP-lowering outcomes compared to XEN45-Phaco in the early post-operative period, up to 6 months after surgery.
The growing global burden of visual impairment necessitates better population eye screening for early detection of eye diseases. However, accessibility to testing is often limited and centralized at ...in-hospital settings. Furthermore, many eye screening programs were disrupted by the COVID-19 pandemic, presenting an urgent need for out-of-hospital solutions. This study investigates the performance of a novel remote perimetry application designed in a virtual reality metaverse environment to enable functional testing in community-based and primary care settings. This was a prospective observational study investigating the performance of a novel remote perimetry solution in comparison with the gold standard Humphrey visual field (HVF) perimeter. Subjects received a comprehensive ophthalmologic assessment, HVF perimetry, and remote perimetry testing. The primary outcome measure was the agreement in the classification of overall perimetry result normality by the HVF (Swedish interactive threshold algorithm–fast) and testing with the novel algorithm. Secondary outcome measures included concordance of individual testing points and perimetry topographic maps. We recruited 10 subjects with an average age of 59.6 (range 28-81) years. Of these, 7 (70%) were male and 3 (30%) were female. The agreement in the classification of overall perimetry results was high (9/10, 90%). The pointwise concordance in the automated classification of individual test points was 83.3% (8.2%; range 75%-100%). In addition, there was good perimetry topographic concordance with the HVF in all subjects. Remote perimetry in a metaverse environment had good concordance with gold standard perimetry using the HVF and could potentially avail functional eye screening in out-of-hospital settings.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, UILJ, UKNU, UL, UM, UPUK
Minimally invasive glaucoma surgery (MIGS) has grown in popularity over the past decade. This systematic review explores the peri‐operative and intraoperative application of anterior segment imaging ...to maximize the efficacy and safety of MIGS. A review of the PubMed, EMBASE and CINAHL databases was conducted, with inclusion criteria restricted to MIGS that had received United States Food and Drug Administration (FDA) premarket approval, FDA 510(K) premarket notification, or were listed as a class 1 device exempt from FDA approval or notification. 21 manuscripts from 21 unique studies were identified pertaining to MIGS devices including the XEN Gel Stent, Trabectome, iStent Inject, 1st‐generation iStent and the Kahook Dual Blade (KDB). Anterior segment imaging modalities included anterior segment optical coherence tomography (AS‐OCT), ultrasound biomicroscopy (UBM), aqueous angiography, OCT volumetric scans and in vivo confocal microscopy. Identification and evaluation of aqueous outflow pathways before and after MIGS have potential for improving patient preoperative patient selection and postoperative outcomes. Intraoperative imaging potentially provides the resolution needed for good visualization of angle anatomy and accurate evaluation of surgical endpoints in angle‐based MIGS. Anterior segment imaging has been used to identify procedural complications, provide objective information on implant location in relation to surrounding anatomy, assess the post‐implantation structural impact of MIGS devices and manage bleb failure and scarring. Technical difficulties in incorporating imaging modalities into the surgical microscope, variable quality of images and optical interference from ocular structures or surgical instruments are remaining barriers, which discourage the widespread clinical use of this technology.
Purpose
To assess intra‐ (repeatability) and inter‐observer (reproducibility) variability of laser speckle flowgraphy (LSFG) for retinal blood flow (RBF) measurement in 20 eyes of wild type ...(C57BL/6J) mice and effect of intravitreal Aflibercept on RBF in optic nerve head (ONH) region of 10 eyes of Ins2 (Akita) diabetic mice.
Methods
‘Mean blur rate (MBR)’ was measured for all quadrants of tissue area (MT), vessel (MV) and total area (MA) of ONH region. Changes in MT were analysed at each timepoint. Repeatability was evaluated by measuring MBR variability without changing mouse head position, and reproducibility after resetting mouse head position by another operator. Coefficient of repeatability (CR) through Bland–Altman plot method coefficient of variation (COV) and Intraclass correlation coefficient (ICC) was calculated. Intravitreal Aflibercept (1 μg) was administered to Akita eyes and intraocular pressure (IOP) was measured using a tonometer at baseline, day 7, 14, 21 and 28 post‐injection. Hurvich and Tsai's criterion was used.
Results
Coefficient of repeatability values of repeatability and reproducibility for all quadrants were within limits of agreement. Reliability was excellent (ICC 0.98–0.99) and reproducibility was moderate to excellent (ICC 0.64–0.96). There was a non‐significant IOP increase in all Akita eyes at Day 28 (p > 0.05), and significant increase in MT in all quadrants at Day 21 and superior, inferior and temporal quadrants at Day 28 (p < 0.05).
Conclusion
Laser speckle flowgraphy demonstrates excellent repeatability and moderate to excellent reproducibility in measuring RBF. Intravitreal Aflibercept injection results in a significant increase in MT up to 28 days post‐injection without significant increase in IOP.
Purpose: To examine the incidence, clinical findings and management of pellet gun-related ocular injuries that occurred during protests in Kashmir region. Methods: This retrospective study included ...records from 777 patients diagnosed with pellet gun-related ocular injuries admitted to a tertiary hospital in Srinagar, India, between July and November 2016. By reviewing the clinical records, the following data were collected: demographics, clinical information pertaining to the injury, imaging reports including computer tomography and ultrasonography B-scan, management in the emergency setting, and follow-up treatment. Results: Mean age was 22.3 ± 7.2 years and majority patients were male (97.7%). In terms of laterality, 94.3% and 5.7% of the patients sustained monocular and binocular injuries, respectively. In terms of the nature of injury, 76.3% of the eyes had open globe injury while 23.7% of the eyes had closed eye injury. Emergency surgical exploration was performed in 67.7% of closed globe injuries while emergency primary repair was done in 91.1% of open globe injuries. The vast majority of patients (98.7%) who required surgery underwent surgical intervention on the day of admission or the next day. Final best-corrected visual acuity (BCVA) after treatment was counting fingers or worse in 82.4% of the eyes. Conclusion: Pellet gun-related ocular injuries resulted in significant ocular morbidity, mostly manifesting as open globe injuries. Treatment often required surgical interventions, but despite expeditious management, visual prognosis remained poor for most of the patients.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The incidence of both cataract and glaucoma is increasing globally. With increasing patient expectation and improved technology, premium intraocular lenses (IOLs), including presbyopia-correcting and ...toric IOLs, are being increasingly implanted today. However, concerns remain regarding the use of premium IOLs, particularly presbyopia-correcting IOLs, in eyes with glaucoma. This systematic review evaluates the use of premium IOLs in glaucoma. A comprehensive search of the MEDLINE database was performed from inception until 1 June 2023. Initial search yielded 1404 records, of which 12 were included in the final review of post-operative outcomes. Studies demonstrated high spectacle independence for distance and good patient satisfaction in glaucomatous eyes, with positive outcomes also in post-operative visual acuity, residual astigmatism, and contrast sensitivity. Considerations in patient selection include anatomical and functional factors, such as the type and severity of glaucomatous visual field defects, glaucoma subtype, presence of ocular surface disease, ocular changes after glaucoma surgery, and the reliability of disease monitoring, all of which may be affected by, or influence, the outcomes of premium IOL implantation in glaucoma patients. Regular reviews on this topic are needed in order to keep up with the rapid advancements in IOL technology and glaucoma surgical treatments.
Surgery has long been an important treatment for limiting optic nerve damage and minimising visual loss in patients with glaucoma. Numerous improvements, modifications, and innovations in glaucoma ...surgery over recent decades have improved surgical safety, and have led to earlier and more frequent surgical intervention in glaucoma patients at risk of vision loss. This review summarises the latest advancements in trabeculectomy surgery, glaucoma drainage device (GDD) implantation, and minimally invasive glaucoma surgery (MIGS). A comprehensive search of MEDLINE, EMBASE, and CENTRAL databases, alongside subsequent hand searches—limited to the past 10 years for trabeculectomy and GDDs, and the past 5 years for MIGS—yielded 2283 results, 58 of which were included in the final review (8 trabeculectomy, 27 GDD, and 23 MIGS). Advancements in trabeculectomy are described in terms of adjunctive incisions, Tenon’s layer management, and novel suturing techniques. Advancements in GDD implantation pertain to modifications of surgical techniques and devices, novel methods to deal with postoperative complications and surgical failure, and the invention of new GDDs. Finally, the popularity of MIGS has recently promoted modifications to current surgical techniques and the development of novel MIGS devices.
Importance
This study reports outcomes of myopic photorefractive keratectomy (PRK) in a mainly ethnic Chinese population in Singapore.
Background
To assess the incidence and associations of corneal ...haze and endothelial cell count (ECC) loss up to 12 months after PRK.
Design
This was a retrospective case series conducted in a tertiary eye centre.
Participants
A total of 158 patients (309 eyes) with a mean age of 22.1 ± 3.4 years were included. The majority was Chinese (97.4%) and male (97.4%). Mean preoperative spherical equivalent was −3.33 ± 1.15 D.
Methods
Eyes were categorized based on postoperative haze severity. A multivariate analysis adjusting for age and use of intraoperative mitomycin‐C (MMC), preoperative sphere and cylinder was performed.
Main outcome measures
Refractive outcomes and corneal haze 3 and 12 months after PRK were assessed. ECC measurements were obtained before PRK and at variable periods postoperatively.
Results
At 12 months, overall efficacy index was 0.98, and safety index was 1.09. Eight (2.5%) eyes underwent enhancement surgery. An analysis was performed on 295 eyes that did not undergo enhancement and had complete clinical data, which demonstrated a decrease in the incidence of haze from 38.2% at 3 months to 9.3% at 12 months. Higher myopia was associated with increased haze severity at 3 months (OR, 1.36; P = .005). Higher astigmatism was associated with increased haze severity at 3 (OR, 1.65; P = .018) and 12 months (OR, 2.32; P = .015). Intraoperative MMC was not associated with haze severity or ECC loss.
Conclusions and relevance
Myopia and astigmatism were associated with increased corneal haze severity. Intraoperative MMC did not accelerate ECC loss. Overall, PRK is effective, predictable and safe in Asian eyes.