Glaciers in the tropical Andes have been rapidly losing mass since the 1970s. In addition to the documented increase in temperature, increases in light-absorbing particles deposited on glaciers could ...be contributing to the observed glacier loss. Here we report on measurements of light-absorbing particles sampled from glaciers during three surveys in the Cordillera Blanca Mountains in Peru. During three research expeditions in the dry seasons (May–August) of 2011, 2012 and 2013, 240 snow samples were collected from 15 mountain peaks over altitudes ranging from 4800 to nearly 6800 m. Several mountains were sampled each of the 3 years and some mountains were sampled multiple times during the same year. Collected snow samples were melted and filtered in the field then later analyzed using the Light Absorption Heating Method (LAHM), a new technique that measures the ability of particles on filters to absorb visible light. LAHM results have been calibrated using filters with known amounts of fullerene soot, a common industrial surrogate for black carbon (BC). As sample filters often contain dust in addition to BC, results are presented in terms of effective black carbon (eBC). During the 2013 survey, snow samples were collected and kept frozen for analysis with a Single Particle Soot Photometer (SP2). Calculated eBC mass from the LAHM analysis and the SP2 refractory black carbon (rBC) results were well correlated (r2 = 0.92). These results indicate that a substantial portion of the light-absorbing particles in the more polluted regions were likely BC. The 3 years of data show that glaciers in the Cordillera Blanca Mountains close to human population centers have substantially higher levels of eBC (as high as 70 ng g−1) than remote glaciers (as low as 2.0 ng g−1 eBC), indicating that population centers can influence local glaciers by sourcing BC.
A photoacoustic spectrometer, a nephelometer, an aethalometer, and an aerosol mass spectrometer were used to measure at ground level real-time aerosol light absorption, scattering, and chemistry at ...an urban site located in North East Mexico City (Instituto Mexicano del Petroleo, Mexican Petroleum Institute, denoted by IMP), as part of the Megacity Impact on Regional and Global Environments field experiment, MILAGRO, in March 2006. Photoacoustic and reciprocal nephelometer measurements at 532 nm accomplished with a single instrument compare favorably with conventional measurements made with an aethalometer and a TSI nephelometer. The diurnally averaged single scattering albedo at 532 nm was found to vary from 0.60 to 0.85 with the peak value at midday and the minimum value at 07:00 a.m. local time, indicating that the Mexico City plume is likely to have a net warming effect on local climate. The peak value is associated with strong photochemical generation of secondary aerosol. It is estimated that the photochemical production of secondary aerosol (inorganic and organic) is approximately 75% of the aerosol mass concentration and light scattering in association with the peak single scattering albedo. A strong correlation of aerosol scattering at 532 nm and total aerosol mass concentration was found, and an average mass scattering efficiency factor of 3.8 m2/g was determined. Comparisons of photoacoustic and aethalometer light absorption with oxygenated organic aerosol concentration (OOA) indicate a very small systematic bias of the filter based measurement associated with OOA and the peak aerosol single scattering albedo.
Ambient measurements are reported of aerosol light absorption from photoacoustic and filter‐based instruments (aethalometer and a particle soot absorption photometer (PSAP)) to provide insight on the ...measurement science. Measurements were obtained during the Big Bend Regional Aerosol and Visibility Observational Study at the Big Bend National Park in South Texas. The aethalometer measurements of black carbon concentration at this site correlate reasonably well with photoacoustic measurements of aerosol light absorption, with a slope of 8.1 m2/g and a small offset. Light absorption at this site never exceeded 2.1 Mm−1 during the month of collocated measurements. Measurements were also obtained, as a function of controlled relative humidity between 40% and 90%, during the Photoacoustic IOP in 2000 at the Department of Energy Southern Great Plains Cloud and Radiation Testbed site (SGP). PSAP measurements of aerosol light absorption correlated very well with photoacoustic measurements, but the slope of the correlation indicated the PSAP values were larger by a factor of 1.61. The photoacoustic measurements of light absorption exhibited a systematic decrease when the RH increased beyond 70%. This apparent decrease in light absorption with RH may be due to the contribution of mass transfer to the photoacoustic signal. Model results for the limiting case of full water saturation are used to evaluate this hypothesis. A second PSAP measured the light absorption for the same humidified samples, and indicated very erratic response as the RH changed, suggesting caution when interpreting PSAP data under conditions of rapid relative humidity change.
Optical properties of atmospheric particles at Mexico City (UNAM) and Queretaro (JQRO) were measured with a Photoacoustic Extinctiometer (PAX) at 870 nm. The Mexico City Metropolitan Area has around ...21 million inhabitants and Queretaro Metropolitan Area has little more than a million. Observations of meteorological parameters (relative humidity, solar radiation, and wind speed) were used to identify the rainy and dry seasons and explain the daily and seasonal behaviors of particles optical properties. The measurements were made from November 1, 2014 to July 31, 2016. At UNAM, the mean values of the scattering coefficient (B
scat
) in cold dry, warm dry, and rainy seasons were 35.8, 27.1, and 31.3 Mm
−1
, respectively; while at JQRO were 10.9, 11.9, and 15.0 Mm
−1
. The average values of the absorption coefficient (B
abs
) at UNAM during the cold dry, warm dry, and rainy seasons were 14.5, 12.7, and 12.7 Mm
−1
, respectively; whereas at JQRO were 4.9, 4.7, and 3.9 Mm
−1
. Both absorption and scattering coefficients showed similar diurnal behaviors, but at UNAM they are three times higher than JQRO. Concentrations of criteria gases (O
3
, NO, NO
2
and NO
x
) were also measured. At UNAM no difference was observed between the seasonal values for the single scattering albedo (SSA); while in JQRO, the rainy season had the highest seasonal value, being 13% higher than in the dry seasons. The Mass Scattering Cross-Section (MSC) values at UNAM were close to 2 m
2
/g; on the other hand, at JQRO the MSC values were lower than 1 m
2
/g. The results suggest a seasonal variability in the aerosol optical properties in both sites, which should be verified with more long-term studies.
A photoacoustic spectrometer has been developed to measure in situ light absorption by aerosol. The measured quantity is the sound pressure produced in an acoustic resonator caused by light ...absorption. The current lower detection limit for light absorption is 0.4 Mm
-1 which corresponds to an elemental carbon mass density of ≈40
ng
m
-3 assuming an efficiency for light absorption of 10
m
2
g
-1. Calibration is performed using simple theory for the instrument along with use of a calibrated microphone and laser. The acoustic resonator is operated in the plane wave mode, which has a quality factor of ≈80, a resonance frequency of ≈500
Hz, and a photoacoustic coefficient of 12.8
Pa (W
m
-1)
-1. The equivalent noise bandwidth of the resonator is ≈5
Hz. Coherent acoustic noise was supressed through the use of acoustic notch filters and laser beam ports at pressure nodes of the resonator. The relatively low-quality factor made it possible to use phase-sensitive detection having an equivalent noise bandwidth of ≈7.5
mHz. This was achieved by vector time averaging the microphone signal for ≈8
min. Two compact, efficient lasers were used during instrument evaluation performed in the Northern Front Range Air Quality Study (Colorado, 1996/97). One was a laser diode pumped, frequency doubled, solid state laser, and the other was a laser diode. Laser wavelengths were 532
nm and 685
nm, and corresponding average powers were 60 and 87
nW. Some examples are provided for light absorption measurements using the photoacoustic instrument and a nearby aethalometer.
The antimetabolite pentyl pantothenamide has broad spectrum antibiotic activity but exhibits enhanced activity against Escherichia coli. The PanDZ complex has been proposed to regulate the ...pantothenate biosynthetic pathway in E. coli by limiting the supply of β-alanine in response to coenzyme A concentration. We show that formation of such a complex between activated aspartate decarboxylase (PanD) and PanZ leads to sequestration of the pyruvoyl cofactor as a ketone hydrate and demonstrate that both PanZ overexpression-linked β-alanine auxotrophy and pentyl pantothenamide toxicity are due to formation of this complex. This both demonstrates that the PanDZ complex regulates pantothenate biosynthesis in a cellular context and validates the complex as a target for antibiotic development.
A series of laboratory experiments at the Fire Laboratory at Missoula (FLAME) investigated chemical, physical, and optical properties of fresh smoke samples from combustion of wildland fuels that are ...burned annually in the western and southeastern US The burns were conducted in the combustion chamber of the US Forest Service Fire Sciences Laboratory in Missoula, Montana. Here we discuss retrieval of optical properties for a variety of fuels burned in FLAME 2, using nephelometer-measured scattering coefficients, photoacoustically-measured aerosol absorption coefficients, and size distribution measurements. Uncertainties are estimated from various instrument characteristics and instrument calibration studies. Our estimates of single scattering albedo for different dry smoke samples varied from 0.428 to 0.990, indicative of observed wide variations in smoke aerosol chemical composition. In selected case studies, we retrieved the complex refractive index from measurements but show that these are highly sensitive to uncertainties in measured size distributions.
The concentration of gases and aerosol particles have been measured at the mountain site of Altzomoni, 4010 m in altitude, located 60 km southeast of Mexico City, 50 km east of Puebla and 70 km ...northeast of Cuernavaca. The objective of this study was to evaluate the properties of gases and particles in the Regional Mixed Layer (RML) of Mexico's Megapolis. Altzomoni is generally above the RML from late evening until late morning at which time the arrival of the RML is marked by increasing concentrations of CO and aerosol particles that reach their maxima in mid-afternoon. The average diurnal cycles for fourteen days in March, 2006 were evaluated during which time the synoptic scale circulation had three principal patterns: from the east (E), southwest (SW) and west northwest (WNW). The original hypothesis was that air arriving from the direction of Mexico City would have much higher concentrations of anthropogenic gases and particles than air from Puebla or Cuernavaca, due to the relatively large differences in populations. In fact, not only were the average, maximum concentrations of CO and O3 (0.3 and 0.1 ppmv) approximately the same for air originating from the WNW and E, but the average maximum concentrations of Peroxyacyl nitrates (PAN,PPN) and particle organic matter (POM) in air from the E exceeded those in air from the WNW. Comparisons of measurements from the mountain site with those made by aircraft during the same period, using the same type of aerosol mass spectrometer, show that the total masses of POM, NO3−, SO42− and NH4+ were approximately the same from aircraft measurements made over Mexico City and when winds were from the east at the mountain site. In contrast 75% of the total aerosol mass at the mountain site was POM whereas over Mexico City the fraction of POM was less than 60%. The measurements suggest the occasional influence of emissions from the nearby volcano, Popocatepetl, as well as possible incursions of biomass combustion; however, the large concentrations of O3, PAN and POM suggest that secondary processes are the major source for these gases and particles. The similar concentrations in gases and particles when air is coming from the E and NWN raises the possibility of recirculation of air from Mexico City and the importance of this mechanism for impacting the regional air quality.
The US. Department of Energy Gasoline/Diesel PM Split Study was conducted to assess the sources of uncertainties in using an organic compound-based chemical mass balance receptor model to quantify ...the relative contributions of emissions from gasoline (or spark ignition SI) and diesel (or compression ignition CI) engines to ambient concentrations of fine particulate matter (PM
2.5
) in California's South Coast Air Basin (SOCAB). In this study, several groups worked cooperatively on source and ambient sample collection and quality assurance aspects of the study but worked independently to perform chemical analysis and source apportionment. Ambient sampling included daily 24-hr PM
2.5
samples at two air quality-monitoring stations, several regional urban locations, and along freeway routes and surface streets with varying proportions of automobile and truck traffic. Diesel exhaust was the dominant source of total carbon (TC) and elemental carbon (EC) at the Azusa and downtown Los Angeles, CA, monitoring sites, but samples from the central part of the air basin showed nearly equal apportionments of CI and SI. CI apportionments to TC were mainly dependent on EC, which was sensitive to the analytical method used. Weekday contributions of CI exhaust were higher for Interagency Monitoring of Protected Visual Environments (IMPROVE; 41 ± 3.7%) than Speciation Trends Network (32 ± 2.4%). EC had little effect on SI apportionment. SI apportionments were most sensitive to higher molecular weight polycyclic aromatic hydrocarbons (indeno123-cdpyrene, benzo(ghi)perylene, and coronene) and several steranes and hopanes, which were associated mainly with high emitters. Apportionments were also sensitive to choice of source profiles. CI contributions varied from 30% to 60% of TC when using individual source profiles rather than the composites used in the final apportionments. The apportionment of SI vehicles varied from 1% to 12% of TC depending on the specific profile that was used. Up to 70% of organic carbon (OC) in the ambient samples collected at the two fixed monitoring sites could not be apportioned to directly emitted PM emissions.
A series of measurements have been performed at Hill Air Force Base to evaluate real-time instruments for measurements of black carbon aerosol and particle-bound PAHs emitted from spark and ignition ...compression vehicles. Vehicles were operated at idle or fast idle in one set of measurements and were placed under load on a dynamometer during the second series. Photoacoustic instruments were developed that operated at a wavelength of 1047 nm where gaseous interference is negligible, although sensitivity to black carbon is good. Compact, efficient, solid-state lasers with direct electronic modulation capabilities are used in these instruments. Black carbon measurements are compared with samples collected on quartz fiber filters that were evaluated using the thermal optical reflectance method. A measure of total particle-bound PAH was provided by photoelectric aerosol sensors (PAS) and is evaluated against a sum of PAH mass concentrations obtained with a filter-denuder combination. The PAS had to be operated with a dilution system held at approximately 150 °C for most of the source sampling to prevent spurious behavior, thus perhaps compromising detection of lighter PAHs. PA and PAS measurements were found to have a high degree of correlation, perhaps suggesting that the PAS can respond to the polycyclic nature of the black carbon aerosol. The PAS to PA ratio for ambient air in Fresno, CA is 3.7 times as large in winter than in summer months, suggesting that the PAS clearly does respond to compounds other than BC when the instrument is used without the heated inlet.