Dynamic balance plays a key role in high-impact sports, such as CrossFit, where athletes are required to maintain balance in various weightlifting exercises. The loss of balance in these ...sport-specific movements may not only affect athlete performance, but also increase the risk of injuries.
The aim of the study is to achieve greater insight into the balance and athlete position during the CrossFit training by means of inertial sensors, with a particular focus on the role of different custom foot orthoses (CFOs) in order to detect correlations with the role of the cavus foot.
A total of 42 CrossFit
athletes, aged 25 to 42 years, were enrolled in this study. One-way ANOVA tests with post-hoc analysis of variance were used to compare foot posture groups and effects of different types of customized foot orthoses.
When comparing the effects of CFOs with the respective balance basal level during the pistol squat exercise, we observed a significant (
= 0.0001) decrease in the sway area, antero-posterior displacement (APD) and medio-lateral displacement (MLD) compared to the basal using both types of CFOs.
No significant positive effects of CFOs were observed in some static tests. On the contrary, positive effects of CFOs and, in particular, postural insoles, are relevant to dynamic balance.
User-friendly, low-cost equipment for preventive screening of severe or deadly pathologies are one of the most sought devices by the National Health Services, as they allow early disease detection ...and treatment, often avoiding its degeneration. In recent years more and more research groups are developing devices aimed at these goals employing gas sensors. Here, nanostructured chemoresistive metal oxide (MOX) sensors were employed in a patented prototype aimed to detect volatile organic compounds (VOCs), exhaled by blood samples collected from patients affected by colorectal cancer and from healthy subjects as a control. Four sensors, carefully selected after many years of laboratory tests on biological samples (cultured cells, human stools, human biopsies, etc.), were based here on various percentages of tin, tungsten, titanium, niobium, tantalum and vanadium oxides. Sensor voltage responses were statistically analyzed also with the receiver operating characteristic (ROC) curves, that allowed the identification of the cut-off discriminating between healthy and tumor affected subjects for each sensor, leading to an estimate of sensitivity and specificity parameters. ROC analysis demonstrated that sensors employing tin and titanium oxides decorated with gold nanoparticles gave sensitivities up to 80% yet with a specificity of 70%.
Background
Extensive literature exists about the treatment of ankle osteochondral lesions, but there is no specific review of retrograde drilling, despite its common application. Indications for ...retrograde drilling are still few and are far from clear, and some evolutions of the technique have recently occurred. The aim of this review is to provide an update on actual applications and techniques of retrograde drilling for ankle osteochondral lesions.
Methods
A systematic review was carried out according to the 2020 PRISMA guidelines. The PubMed and Embase databases were searched in June 2023. The search string focused on studies related to retrograde drilling in the treatment of ankle osteochondral lesions.
Results
Twenty-one articles for a total of 271 ankles were included in this review. The mean length of the treated lesions was 11.4 mm. Different navigation systems were used, with fluoroscopy the most commonly used. Various adjuvants were employed after drilling, with bone graft the most commonly applied. In most cases, postoperative patient satisfaction and symptom relief were reported, and no complications occurred. Retrograde drilling was found to be suitable for the treatment of subchondral cysts with intact cartilage or small lesions. Some modifications to the original technique may allow surgical indications to be extended to more complex cases.
Conclusions
Middle-term results of retrograde drilling showed postoperative satisfaction and symptom relief with both original and modified techniques. Additional research is required to investigate the long-term results.
Level of evidence
: IV.
Trial registration
: This systematic review was registered on PROSPERO (id number: CRD42022371128).
Foot and ankle injuries are common in many sports. One of the main athletes issues is the time for sport resumption after trauma. Recently, extensive efforts have been made to speed up the athletes’ ...return-to-sport and to prevent joint degeneration. Among the conservative treatment options, biophysical stimulation with pulsed electromagnetic fields (PEMFs) is listed. This narrative review aims to outline current applications of PEMFs in main foot and ankle sport-related injuries, in particular in the treatment of bone marrow edema, osteochondral defects, fractures, and nonunions. Despite further high-quality studies on foot and ankle injuries are needed, PEMFs seem to be a valid aid to enhance the endogenous osteogenesis, to resolve the bone marrow edema, to inhibit the joint inflammation, preserving articular cartilage degeneration, and to relieve pain.
Subtalar distraction arthrodesis (SDA) is a surgical procedure designed to treat hindfoot deformities associated with isolated subtalar joint arthritis. In 1996, Fitzgibbons was the first to observe ...that, in some cases, hindfoot fusion appeared to be associated with the development of tibiotalar valgus tilt. Since then, few studies have addressed this issue. Given that hindfoot fusion can be performed using various techniques, this study investigated the potential tibiotalar joint frontal or sagittal modifications resulting from the modified Grice–Green technique. All the consecutive patients who underwent the modified Grice–Green procedure were included. The patient records were reviewed to extract demographic data. Weight-bearing foot and ankle radiographs were assessed to measure the talar tilt angle and the tibiotalar ratio on the same picture archiving and communication system by three independent observers. A total of 69 patients met the criteria for inclusion. The mean talar tilt showed no substantial changes, since the increase from 1.46 ± 1.62 preoperatively to 1.93 ± 2.19 at a minimum of 8 months postoperatively was not statistically significant (p = 0.47). The average preoperative tibiotalar ratio significantly increased from 33.4 ± 4.4% to 35 ± 4% postoperatively (p = 0.007), although remaining within the normal range, indicating a possible realignment of the posterior facet of the subtalar joint. In conclusion, this study highlights the effectiveness of the modified Grice–Green procedure in achieving a favorable realignment without impacting the ankle joint, particularly regarding tibiotalar valgus tilt.
Retrograde drilling (RD) is a minimally invasive surgical procedure mainly used for non-displaced osteochondral lesions (OCL) of the talus, dealing with subchondral necrotic sclerotic lesions or ...subchondral cysts without inducing iatrogenic articular cartilage injury, allowing the revascularization of the subchondral bone and new bone formation.
This systematic review collected and analyzed the clinical studies of the last 10 years of literature, focusing not only on the clinical results but also on patients' related factors (gender, BMI, age and complications).
Sixteen clinical studies were retrieved, and differences in the type of study, follow-up, number and age of patients, lesion type, dimensions, grades and comparison groups were observed, making it difficult to draw conclusions. Nevertheless, lesions on which RD showed the best results were those of I-III grades and not exceeding 150 mm
in size, showing overall positive results, a good rate of patient satisfaction, improvements in clinical scores, pain reduction and return to daily activities and sports.
There are still few studies dealing with the issue of post-surgical complications and gender-related responses. Further clinical or preclinical studies are thus mandatory to underline the success of this technique, also in light of gender differences.
While several intraoperative devices have been described in the literature for assessing leg length discrepancy (LLD), none have been utilized during total hip arthroplasty (THA) performed via the ...Anterior Minimally Invasive Surgery (AMIS) approach. The aim of this prospective study was to evaluate the efficacy and accuracy of a compass device in assessing leg length during THA performed using the AMIS technique. A prospective study was conducted involving 35 patients who consecutively underwent unilateral primary THA using the AMIS technique at our department from September 2017 to December 2018. LLD was measured by comparing preoperative and postoperative anteroposterior radiographs of the pelvis, independently assessed by two observers. The mean preoperative LLD was 3.6 (SD 3.9, range, 0.2–19.3) mm. The mean postoperative LLD was 2.5 (SD 3.0, range, 0–12.2) mm. A postoperative LLD of less than 5 mm was observed in 88.2% of cases, with 94.1% having values less than 10 mm. In conclusion, the compass device emerged as a valuable tool for ensuring precise limb length control in THA with the AMIS approach, offering both efficiency and cost-effectiveness in clinical practice.
The optimal surgical treatment of intra-articular calcaneal fractures (IACF) is still under debate. In the literature, results are based on clinical or radiographical findings. Few studies have ...evaluated the effect of patient expectations on patient-reported outcomes after surgery and little is known about outcomes directly reported by the patient who experienced it. Patient reported outcome measures (PROMs) may represent a viable and useful tool for evaluating the efficacy of the procedure and can be considered as an indicators of health-care quality. The aim of this study is to evaluate PROMs after minimally invasive reduction and percutaneous Kirschner-wires fixation for IACF, and to compare PROMs to pre-operative and last follow-up radiographic findings.
33 consecutive patients with IACF treated with minimally invasive reduction and percutaneous K-wires fixation were included. Data collection included demographics, pre-operative and last available Böhler and Gissane angle X-rays, foot function index (FFI), and foot and ankle outcome score (FAOS).
At a mean follow up of 36.7 months, the mean FFI score was 24.3 ± 19.9 and the mean FAOS score was 68 ± 24.8. Patients with better Gissane angle showed better activity limitations FFI subscores. Moreover, worse pre-operative Gissane and Böhler angle were significantly associated with a worse total FAOS score and subscores.
Minimally invasive reduction and percutaneous K-wires fixation provided satisfactory PROMs. Despite these results, prospective randomized studies are required to confirm the validity and reliability of PROMs in evaluating different treatments.
Background: Total ankle arthroplasty (TAA) has grown in popularity and indications, with encouraging results over time. Today, preoperative and postoperative evaluations are mainly performed using ...clinical test and diagnostic imaging, but there is a deficiency in objectively evaluating the biomechanics of the foot and ankle, which serve as the functional markers for monitoring the effectiveness and outcomes of surgery. Inertial measurement units associated with plantar pressure measurements may provide an accurate and reliable method of evaluating function through the analysis of gait and ankle joint mobility. The aim of this study was to introduce an innovative technology, to assess its accuracy and feasibility compared to standard clinical assessment methods and to objectify kinematic outcomes in patients with end-stage ankle OA before and after TAA surgery. Methods: A consecutive series of eight patients with symptomatic end-stage osteoarthritis and treated with TAA was prospectively evaluated using clinical scores (AOFAS, MOxFQ, VAS, SF-36, 17-IFFI), physical tests (FPI, ALT), plantar pressure measurements with FLEX EPS/R2 Letsense® baropodometric platform, gait analysis and wearable sensors-based ankle motion and kinematic outcomes using Wiva Science inertial sensors by Letsense®. Data were collected preoperatively and 4 months after surgery. Results: All PROMs exhibited statistical significance in improvement from pre- to postoperative periods, except for one. Physical examinations showed no significant changes of the foot shape and alignment. Plantar pressure analyses revealed no significant changes in static and dynamic evaluations, but a more uniform distribution of plantar pressure was observed between the two periods. Inertial sensor parameters demonstrated no significant differences, except for a significant reduction in stride length and step length for the operated foot after surgery. Conclusions: Gait analysis using inertial sensors and plantar pressure measurements offer ease of handling, cost effectiveness, portability and swift data reading, making them highly appealing for widespread clinical use. Integrating these tools into the routine assessments of patients with TAA holds promise for advancing precision of treating this condition and our depth of its understanding, contributing to more comprehensive and insightful patient care.