We present the performances of two 92% enriched 130TeO2 crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of 130Te. The ...crystals, 435 g each, show an energy resolution, evaluated at the 2615 keV γ-line of 208Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive contamination arises from 238U (15 and 8 μBq/kg, respectively). The internal activity of the most problematic nuclei for neutrinoless double beta decay, 226Ra and 228Th, are both evaluated as <3.1 μBq/kg for one crystal and <2.3 μBq/kg for the second. Thanks to the readout of the weak Cherenkov light emitted by β/γ particles by means of Neganov–Luke bolometric light detectors we were able to perform an event-by-event identification of β/γ events with a 95% acceptance level, while establishing a rejection factor of 98.21% and 99.99% for α particles.
The CUORE experiment will search for neutrinoless double-beta decay of super(130)Te with an array of 988 TeO sub(2) bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to ...the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first ...large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in Se-82, the (ZnSe)-Se-82 crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three (ZnSe)-Se-82 crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radiopurity complies with the requirements of CUPID-0.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Neutrinoless double-beta (0vββ) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic ...Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for 0vββ decay of sup.130Te using an array of 988 TeO.sub.2 crystal bolometers operated at 10 mK. The detector will contain 206 kg of sup.130Te and have an average energy resolution of 5 keV; the projected 0vββ decay half-life sensitivity after five years of livetime is 1.6 x 10.sup.26 γ at 1σ (9.5 x 10.sup.25 γ at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). In this paper, we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.
We report on a search for double beta decay of Formula omitted to the first Formula omitted excited state of Formula omitted using a Formula omitted exposure of Formula omitted collected with the ...CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double beta decay modes. We find no evidence for either mode and place lower bounds on the half-lives: Formula omitted and Formula omitted ( Formula omitted). Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: Formula omitted and Formula omitted ( Formula omitted).
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Initial performance of the CUORE-0 experiment Artusa, D. R.; Avignone, F. T.; Azzolini, O. ...
The European physical journal. C, Particles and fields,
08/2014, Letnik:
74, Številka:
8
Journal Article
Recenzirano
Odprti dostop
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of
130
Te
. We present the first data analysis with
7.1
kg
·
y
of total
...TeO
2
exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to
2.57
MeV
) and in the
α
background-dominated region (2.70 to
3.90
MeV
) have been measured to be
0.071
±
0.011
and
0.019
±
0.002
counts
/
(
keV
·
kg
·
y
)
, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is
5.7
keV
. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first ...large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in Formula: see textSe, the ZnFormula: see textSe crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three ZnFormula: see textSe crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We present here an innovative cryogenic light detector capable to measure a few tens of eV signal thanks to the amplification assisted by the Neganov–Luke effect. The thermal signal boost in the ...presence of an electric field allows us to improve the signal-to-noise ratio reaching a baseline noise of around 20 eV. This device – coupled to an enriched 130TeO2 bolometer (435 g) – registered 160 eV Cherenkov light signal induced by 2615 keV 208Tl with a signal to noise ratio about 6:1. Since α particles emitted in decays of natural radionuclides do not produce the Cherenkov radiation, we were able to achieve an efficient α∕γ separation in the region of interest for neutrinoless double beta decay of 130Te (Q-value is 2527 keV). Specifically, a rejection factor of 99.9% for α particles was obtained with a 98.3% acceptance of β∕γ events. The achieved α rejection efficiency is required to reduce the dominant α background in the follow-up of the CUORE experiment (CUPID), a ton-scale bolometric search with particle identification.
Neutrinoless double beta decay (
0
ν
β
β
) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review ...the status and outlook for bolometric
0
ν
β
β
decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric
0
ν
β
β
experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (
|
m
e
e
|
) of order 10–20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.
Celotno besedilo