We propose a large-area, cost-effective muon telescope detector (MTD) at mid-rapidity for the solenoidal tracker at the RHIC (STAR) and for the next generation of detectors at a possible electron-ion ...collider. We utilize large multi-gap resistive plate chambers with long readout strips (long-MRPC) in the detector design. The results from cosmic ray and beam tests show that the intrinsic timing and spatial resolution for a long-MRPC are 60-70 ps and ~1 cm, respectively. The performance of the prototype muon telescope detector at STAR indicates that muon identification at a transverse momentum of a few GeV/c can be achieved by combining information from track matching with the MTD, ionization energy loss in the time projection chamber and time-of-flight measurements. A primary muon over secondary muon ratio of better than 1/3 can be achieved. This provides a promising device for future quarkonium programs and primordial dilepton measurements at the RHIC. Simulations of the muon efficiency, the signal-to-background ratio of J/psi, the separation of 1S from 2S+3S states and the electron-muon correlation from charm pair production in the RHIC environment are presented.
Performance of a new LMRPC prototype for the STAR MTD system Wang, Y.; Chen, H.S.; Ding, W.C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2011, Letnik:
640, Številka:
1
Journal Article
Recenzirano
A new prototype of a Long-Strip Multi-Gap Resistive Plate Chamber (LMRPC) for the STAR Muon Telescope Detector (MTD) at RHIC has been developed. This prototype has an active area of 52×90
cm
2 and ...consists of six 250
μm wide gaps. Each detector has 12 strips, read-out at both ends, which are each 3.8
cm wide and 90
cm long with 0.6
cm intervals. In cosmic-ray tests, the efficiency was larger than 95% and the time resolution was ∼75
ps for the 94% Freon, 5% iso-butane, and 1% SF
6 gas mixture. There was good uniformity in the performance across the different strips. The module was also tested in a proton beam at IHEP in Beijing. The efficiency was close to 100% and the best timing resolution achieved was 55
ps for the 90% Freon, 5% iso-butane, and 5% SF
6 gas mixture. Trigger scans along and across the strip direction were also performed.
The STAR Vertex Position Detector Llope, W.J.; Zhou, J.; Nussbaum, T. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
09/2014, Letnik:
759
Journal Article
Recenzirano
Odprti dostop
The 2×3 channel pseudo Vertex Position Detector (pVPD) in the STAR experiment at RHIC has been upgraded to a 2×19 channel detector in the same acceptance, called the Vertex Position Detector (VPD). ...This detector is fully integrated into the STAR trigger system and provides the primary input to the minimum-bias trigger in Au+Au collisions. The information from the detector is used both in the STAR Level-0 trigger and offline to measure the location of the primary collision vertex along the beam pipe and the event “start time” needed by other fast-timing detectors in STAR. The offline timing resolution of single detector channels in full-energy Au+Au collisions is ~100ps, resulting in a start time resolution of a few tens of picoseconds and a resolution on the primary vertex location of ~1cm.
The BRAHMS experiment at RHIC Adamczyk, M; Antvorskov, L; Ashktorab, K ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2003, Letnik:
499, Številka:
2
Journal Article
Recenzirano
The BRAHMS experiment at RHIC was conceived to pursue the understanding of nuclear matter under extreme conditions by detailed measurements of charged hadrons over the widest possible range of ...rapidity and transverse momentum. The experiment consists of two spectrometers with complementary charged hadron detection capabilities as well as a series of global detectors for event characterization. A series of tracking detectors, time-of-flight arms and Cherenkov detectors enables momentum determination and particle identification over a wide range of rapidity and transverse momentum. Technical details and performance results are presented for the various detector subsystems. The performance of the entire system working together is shown to meet the goals of the experiment.
The 2x3 channel pseudo Vertex Position Detector (pVPD) in the STAR experiment at RHIC has been upgraded to a 2x19 channel detector in the same acceptance, called the Vertex Position Detector (VPD). ...This detector is fully integrated into the STAR trigger system and provides the primary input to the minimum-bias trigger in Au+Au collisions. The information from the detector is used both in the STAR Level-0 trigger and offline to measure the location of the primary collision vertex along the beam pipe and the event "start time" needed by other fast-timing detectors in STAR. The offline timing resolution of single detector channels in full-energy Au+Au collisions is ~100 ps, resulting in a start time resolution of a few tens of picoseconds and a resolution on the primary vertex location of ~1 cm.
We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion ...collider. We utilize Multi-gap Resistive Plate Chambers with large modules and long readout strips (Long-MRPC) in the detector design. The results from cosmic ray and beam tests show the intrinsic timing and spatial resolution for a Long-MRPC are 60-70 ps and \(\sim1\) cm, respectively. The prototype performance of such a novel muon telescope detector at STAR indicates that muon identification at the transverse momentum of a few GeV/\(c\) can be achieved through the combined information of track matching with the MTD, ionization energy loss in the Time Projection Chamber, and time-of-flight measurements. A primary muon over secondary muon ratio of better than 1/3 can be achieved. This provides a promising device for future quarkonium programs and primordial dilepton measurements at RHIC. Simulations of the muon efficiency, the signal-to-background ratio of \(J/\psi\), the separation of \(\Upsilon\) 1S from 2S+3S states, and the electron-muon correlation from charm pair production in the RHIC environment are presented.
BACKGROUND. There is considerable variability in COVID-19 outcomes among younger adults, and some of this variation may be due to genetic predisposition. METHODS. We combined individual level data ...from 13,888 COVID-19 patients (n = 7185 hospitalized) from 17 cohorts in 9 countries to assess the association of the major common COVID-19 genetic risk factor (chromosome 3 locus tagged by rs10490770) with mortality, COVID-19-related complications, and laboratory values. We next performed metaanalyses using FinnGen and the Columbia University COVID-19 Biobank. RESULTS. We found that rs10490770 risk allele carriers experienced an increased risk of all-cause mortality (HR, 1.4; 95% CI, 1.2-1.7). Risk allele carriers had increased odds of several COVID-19 complications: severe respiratory failure (OR, 2.1; 95% CI, 1.6-2.6), venous thromboembolism (OR, 1.7; 95% CI, 1.2-2.4), and hepatic injury (OR, 1.5; 95% CI, 1.2-2.0). Risk allele carriers age 60 years and younger had higher odds of death or severe respiratory failure (OR, 2.7; 95% CI, 1.8-3.9) compared with those of more than 60 years (OR, 1.5; 95% CI, 1.2-1.8; interaction, P = 0.038). Among individuals 60 years and younger who died or experienced severe respiratory failure, 32.3% were risk-variant carriers compared with 13.9% of those not experiencing these outcomes. This risk variant improved the prediction of death or severe respiratory failure similarly to, or better than, most established clinical risk factors. CONCLUSIONS. The major common COVID-19 genetic risk factor is associated with increased risks of morbidity and mortality, which are more pronounced among individuals 60 years or younger. The effect was similar in magnitude and more common than most established clinical risk factors, suggesting potential implications for future clinical risk management.
Organic mixed ionic electronic conductors (OMIECs) have the potential to enable diverse new technologies, ranging from biosensors to flexible energy storage devices and neuromorphic computing ...platforms. However, a study of these materials in their operating state, which convolves both passive and potential-driven solvent, cation, and anion ingress, is extremely difficult, inhibiting rational material design. In this report, we present a novel approach to the in situ studies of the electrochemical switching of a prototypical OMIEC based on oligoethylene glycol (oEG) substitution of semicrystalline regioregular polythiophene via grazing-incidence X-ray scattering. By studying the crystal lattice both dry and in contact with the electrolyte while maintaining potential control, we can directly observe the evolution of the crystalline domains and their relationship to film performance in an electrochemically gated transistor. Despite the oEG side-chain enabling bulk electrolyte uptake, we find that the crystalline regions are relatively hydrophobic, exhibiting little (less than one water per thiophene) swelling of the undoped polymer, suggesting that the amorphous regions dominate the reported passive swelling behavior. With applied potential, we observe that the π–π separation in the crystals contracts while the lamella spacing increases in a balanced fashion, resulting in a negligible change in the crystal volume. The potential-induced changes in the crystal structure do not clearly correlate to the electrical performance of the film as an organic electrochemical transistor, suggesting that the transistor performance is strongly influenced by the amorphous regions of the film.
Low-frequency coding DNA sequence variants in the proprotein convertase subtilisin/kexin type 9 gene (PCSK9) lower plasma low-density lipoprotein cholesterol (LDL-C), protect against risk of coronary ...heart disease (CHD), and have prompted the development of a new class of therapeutics. It is uncertain whether the PCSK9 example represents a paradigm or an isolated exception. We used the “Exome Array” to genotype >200,000 low-frequency and rare coding sequence variants across the genome in 56,538 individuals (42,208 European ancestry EA and 14,330 African ancestry AA) and tested these variants for association with LDL-C, high-density lipoprotein cholesterol (HDL-C), and triglycerides. Although we did not identify new genes associated with LDL-C, we did identify four low-frequency (frequencies between 0.1% and 2%) variants (ANGPTL8 rs145464906 c.361C>T; p.Gln121∗, PAFAH1B2 rs186808413 c.482C>T; p.Ser161Leu, COL18A1 rs114139997 c.331G>A; p.Gly111Arg, and PCSK7 rs142953140 c.1511G>A; p.Arg504His) with large effects on HDL-C and/or triglycerides. None of these four variants was associated with risk for CHD, suggesting that examples of low-frequency coding variants with robust effects on both lipids and CHD will be limited.