Using the 1.32 Formula omitted statistics collected at the Formula omitted peak with the KEDR detector at the VEPP-4M Formula omittedcollider, we measured the branching fractions of Formula omitted ...meson decays to the final states 2( Formula omitted, Formula omitted, 2( Formula omitted and Formula omitted. The results obtained for the decays Formula omitted2( Formula omitted, Formula omitted contradict the measurements performed by other groups in the last century, but agree well with recent results of BABAR and BESIII collaborations.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
42.
Calorimetry of the CMD-3 detector Akhmetshin, R R; Anisenkov, A V; Aulchenko, V M ...
Journal of physics. Conference series,
11/2017, Letnik:
928, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The CMD-3 detector has been collecting data since 2010 at the e+e− collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high ...luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e+e− annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.
The Spherical Neutral Detector (SND) is an experiment for e+e− annihilation study at low energies 0.2−2 GeV. The light quark anti−quark bound states are the main subject of study at these energies. ...They express themselves as resonances in the e+e− hadronic cross sections. Hadronic cross sections could be recalculated to hadronic vacuum polarization (HVP). The Standard Model predictions today are limited by HVP which is not calculable with modern QCD theory. In this talk we present the review of the hadronic cross sections measurements at SND and new measurements: e+e− → π+π−, π0γ, π+π−π0, ωπ0, K+K−η, η, KsKLπ0, π+π−π0η, ωπ0η e.t.c.
We present a measurement of the pion form factor based on e+e− annihilation data from the CMD-2 detector in the energy range 0.6<s<1.0 GeV with a systematic uncertainty of 0.8%. A data sample is five ...times larger than that used in our previous measurement.
SND tracking system—Tests with cosmic muons Aulchenko, V.M.; Bogdanchikov, A.G.; Botov, A.A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2009, 2009-1-00, Letnik:
598, Številka:
1
Journal Article
Recenzirano
Tracking system of the SND detector is fully assembled, equipped and tested with cosmic muons in 2007. During these tests operation conditions of the system were checked and optimized and main ...parameters of the system were measured. Design values of gas gain, detection efficiency and space resolution were achieved. Tracking system is ready for installation into the SND detector and coming data taking at the VEPP-2000
e
+
e
-
-collider in Novosibirsk.
Barrel calorimeter of the CMD-3 detector Anisenkov, A.V.; Aulchenko, V.M.; Barkov, L.M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
Since 2010 the CMD-3 detector has been collecting data at the e+e− collider VEPP-2000 at Budker Institute of Nuclear Physics. CMD-3 is a general purpose detector designed to study e+e− annihilation ...into hadrons in the wide energy range s=0.3–2GeV. The CMD-3 barrel electromagnetic calorimeter consists of two subsystems: closest to the beam pipe is the Liquid Xenon calorimeter and the outer one is based on CsI scintillation crystals. The design of the calorimeter and its current performance are presented.
This paper reports measurements of the hadronic cross sections with the CMD-3 detector at the VEPP-2000 electron-positron collider. The overall size of the data sample analyzed is about 60 pb-1, ...collected by the CMD- 3 running since December 2010 up to June 2013 in the c.m. energy range from 0.32 to 2.0 GeV. The preliminary results of data analysis for various modes of e+e−→hadrons are discussed.
Since December 2010, the CMD-3 detector has collected data at the electronpositron collider VEPP-2000. The sample of the accumulated data corresponds to about 60 pb−1 of integrated luminosity in the ...c.m. energy from 0.32 up to 2 GeV. Preliminary results of the analysis of various processes e+e− annihilation to hadrons are presented. It is shown the processes with multihadron events have several intermediate states which must be taken into account to correctly describe the angular and invariant mass distributions as well as cross section dependence versus energy.
The KEDR detector Anashin, V. V.; Aulchenko, V. M.; Baldin, E. M. ...
Physics of particles and nuclei,
07/2013, Letnik:
44, Številka:
4
Journal Article
Recenzirano
The KEDR detector is a universal magnetic detector designed for studying the
c
- and
b
-quarks and two-photon physics, and is employed at the VEPP-4M
e
+
e
−
collider. A specific feature of the ...experiment is the measurement of absolute beam energy using two methods: the resonant depolarization and the faster but less precise Compton backscattering of laser photons. This allowed a large series of measurements to be performed, in which the accuracy of determination of such fundamental parameters of particles as mass and total and leptonic widths was improved.
Since 2010 the CMD-3 detector has been collecting data at the e+e− collider VEPP-2000 in the Budker Institute of Nuclear Physics. One of the main goals of experiments with CMD-3 detector is the ...precise measurement of the cross sections of the e+e− annihilation into hadrons. For a large number of processes the main source of systematic uncertainty in cross sections determination due to accuracy of polar angles determination of the tracks. Z-chamber is used for the reconstruction of the track longitudinal coordinate which is with low systematic uncertainty. The measurement of longitudinal coordinates is performed by the collecting of the charge which is induced on the strip cathodes of the Z-chamber. The algorithms of the reconstruction of cathodes clusters and calibration procedure are presented.