Abstract Background A series of models have been developed to identify patients at high risk for poor outcomes after transcatheter aortic valve replacement (TAVR) to help guide treatment choices, ...offer patients realistic expectations of long-term outcomes, and support decision making. Objectives This study examined the performance of the previously developed TAVR Poor Outcome risk models in an external dataset and explored the incremental contribution of geriatric domains to model performance. Methods Poor outcome after TAVR was defined as death, poor quality of life (QOL), or decline in QOL, as assessed using the Kansas City Cardiomyopathy Questionnaire. We tested 4 TAVR Poor Outcome risk models: 6-month and 1-year full and clinical (reduced) models. We examined each model’s discrimination and calibration in the CoreValve trial dataset, and then tested the incremental contribution of frailty and disability markers to the model’s discrimination using the incremental discrimination index. Results Among 2,830 patients who underwent TAVR in the CoreValve US Pivotal Extreme and High Risk trials and associated continued access registries, 31.2% experienced a poor outcome at 6 months following TAVR (death, 17.6%; very poor QOL, 11.6%; QOL decline, 2.0%) and 50.8% experienced a poor outcome at 1 year (death, 30.2%; poor QOL, 19.6%; QOL, decline 1.0%). The models demonstrated similar discrimination as in the Placement of Aortic Transcatheter Valves Trial cohorts (c-indexes, 0.637 to 0.665) and excellent calibration. Adding frailty as a syndrome increased the c-indexes by 0.000 to 0.004 (incremental discrimination index, p < 0.01 for all except the 1-year clinical model), with the most important individual components being disability and unintentional weight loss. Conclusions Although discrimination of the TAVR Poor Outcome risk models was generally moderate, calibration was excellent among patients with different risk profiles and treated with a different TAVR device. These findings demonstrated the value of these models for individualizing outcome predictions in high-risk patients undergoing TAVR.
BACKGROUND:In patients with transthyretin amyloid cardiomyopathy, tafamidis reduces all-cause mortality and cardiovascular hospitalizations and slows decline in quality of life compared with placebo. ...In May 2019, tafamidis received expedited approval from the US Food and Drug Administration as a breakthrough drug for a rare disease. However, at $225 000 per year, it is the most expensive cardiovascular drug ever launched in the United States, and its long-term cost-effectiveness and budget impact are uncertain. We therefore aimed to estimate the cost-effectiveness of tafamidis and its potential effect on US health care spending.
METHODS:We developed a Markov model of patients with wild-type or variant transthyretin amyloid cardiomyopathy and heart failure (mean age, 74.5 years) using inputs from the ATTR-ACT trial (Transthyretin Amyloidosis Cardiomyopathy Clinical Trial), published literature, US Food and Drug Administration review documents, healthcare claims, and national survey data. We compared no disease–specific treatment (“usual care”) with tafamidis therapy. The model reproduced 30-month survival, quality of life, and cardiovascular hospitalization rates observed in ATTR-ACT; future projections used a parametric survival model in the control arm, with constant hazards reduction in the tafamidis arm. We discounted future costs and quality-adjusted life-years by 3% annually and examined key parameter uncertainty using deterministic and probabilistic sensitivity analyses. The main outcomes were lifetime incremental cost-effectiveness ratio and annual budget impact, assessed from the US healthcare sector perspective. This study was independent of the ATTR-ACT trial sponsor.
RESULTS:Compared with usual care, tafamidis was projected to add 1.29 (95% uncertainty interval, 0.47–1.75) quality-adjusted life-years at an incremental cost of $1 135 000 (872 000–1 377 000), resulting in an incremental cost-effectiveness ratio of $880 000 (697 000–1 564 000) per quality-adjusted life-year gained. Assuming a threshold of $100 000 per quality-adjusted life-year gained and current drug price, tafamidis was cost-effective in 0% of 10 000 probabilistic simulations. A 92.6% price reduction from $225 000 to $16 563 would be necessary to make tafamidis cost-effective at $100 000/quality-adjusted life-year. Results were sensitive to assumptions related to long-term effectiveness of tafamidis. Treating all eligible patients with transthyretin amyloid cardiomyopathy in the United States with tafamidis (n=120 000) was estimated to increase annual healthcare spending by $32.3 billion.
CONCLUSIONS:Treatment with tafamidis is projected to produce substantial clinical benefit but would greatly exceed conventional cost-effectiveness thresholds at the current US list price. On the basis of recent US experience with high-cost cardiovascular medications, access to and uptake of this effective therapy may be limited unless there is a large reduction in drug costs.
Abstract Background In patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), studies have suggested that reduced left ventricular (LV) ejection fraction (LVEF) and ...low aortic valve gradient (AVG) are associated with worse long-term outcomes. Because these conditions commonly coexist, the extent to which they are independently associated with outcomes after TAVR is unknown. Objectives The purpose of this study was to evaluate the impact of LVEF and AVG on clinical outcomes after TAVR and to determine whether the effect of AVG on outcomes is modified by LVEF. Methods Using data from 11,292 patients who underwent TAVR as part of the Transcatheter Valve Therapies Registry, we examined rates of 1-year mortality and recurrent heart failure in patients with varying levels of LV dysfunction (LVEF <30% vs. 30% to 50% vs. >50%) and AVG (<40 mm Hg vs. ≥40 mm Hg). Multivariable models were used to estimate the independent effect of AVG and LVEF on outcomes. Results During the first year of follow-up after TAVR, patients with LV dysfunction and low AVG had higher rates of death and recurrent heart failure. After adjustment for other clinical factors, only low AVG was associated with higher mortality (hazard ratio: 1.21; 95% confidence interval: 1.11 to 1.32; p < 0.001) and higher rates of heart failure (hazard ratio: 1.52; 95% confidence interval: 1.36 to 1.69; p <0.001), whereas the effect of LVEF was no longer significant. There was no evidence of effect modification between AVG and LVEF with respect to either endpoint. Conclusions In this series of real-world patients undergoing TAVR, low AVG, but not LV dysfunction, was associated with higher rates of mortality and recurrent heart failure. Although these findings suggest that AVG should be considered when evaluating the risks and benefits of TAVR for individual patients, neither severe LV dysfunction nor low AVG alone or in combination provide sufficient prognostic discrimination to preclude treatment with TAVR.
In a randomized trial involving patients with aortic stenosis, the use of a cerebral protection device during TAVR did not decrease the risk of periprocedural stroke, but there were fewer disabling ...strokes.
Abstract Background Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of ...this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALY; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. Conclusions In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement Medtronic CoreValve U.S. Pivotal Trial; NCT01240902 )
The aim of this study was to examine the independent association of short-term complications of transcatheter aortic valve replacement (TAVR) with survival and quality of life at 1 year.
Prior ...studies have examined the mortality and cost implications of various complications of TAVR. However, many of these complications may primarily affect patients’ quality of life after TAVR, which has not been previously studied.
Among patients at intermediate or high surgical risk who underwent TAVR as part of the PARTNER (Placement of Aortic Transcatheter Valve) 2 studies and survived 30 days, the association between complications within the 30 days after TAVR and mortality and quality of life at 1 year was examined. Quality of life was assessed using the Kansas City Cardiomyopathy Questionnaire and the Short-Form 12. Complications assessed included major and minor stroke, life-threatening and major bleeding, vascular injury, stage 3 acute kidney injury, new pacemaker implantation, and mild and moderate or severe paravalvular leak (PVL). Multivariable models that included all complications as well as baseline clinical factors were used to examine the independent association of each complication with outcomes.
Among 3,763 TAVR patients, major stroke and stage 3 acute kidney injury were associated with markedly increased risk for 1-year mortality, with adjusted hazard ratios of 5.4 (95% confidence interval CI: 3.1 to 9.5) and 4.9 (95% CI: 2.7 to 8.8), respectively, as well as poorer quality of life among survivors (reductions in 1-year Kansas City Cardiomyopathy Questionnaire overall summary score of 15.1 points 95% CI: 24.8 to 5.3 points and 14.7 points 95% CI: 25.6 to 3.8 points, respectively). Moderate or severe PVL, life-threatening bleeding, and major bleeding were each associated with a more modest increase in mortality and decrement in quality of life, whereas mild PVL was associated with a small decrease in quality of life. After adjusting for baseline characteristics and other complications, need for a new pacemaker, minor stroke, and vascular injury were not independently associated with poor outcomes.
Among patients undergoing TAVR, similar events are associated with increased mortality and impaired quality of life at 1 year. These results suggest that despite considerable progress, efforts to further reduce stroke, acute kidney injury, bleeding, and moderate or severe PVL are likely to yield important clinical benefits and remain key targets for device iteration and procedural improvement.
BACKGROUND—Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) ...using a high-pressure balloon can be performed to facilitate VIV TAVR.
METHODS AND RESULTS—We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P<0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm, P<0.001). No procedural complications were reported.
CONCLUSIONS—BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area.