We have studied bound states of the Schrödinger equation for a linear potential together with any finite number (P) of Dirac delta functions. Forx
where 0f; 0x 1x 2x P , theσ i are arbitrary real ...numbers, and the potential is infinite forx
Describes the development of cryptography under the following sections: conventional cryptography; digital signatures; cipher systems; shift registers; speech scramblers; JAGUAR, the first ...commercially available frequency hopping radio; and secure payment systems. (Abstract quotes from original text)
Large-area, high-precision drift chambers, based on the “jet cell” concept, have been developed for the muon spectrometer of the ATLAS experiment at LHC. Emphasis is placed on the control and ...reduction of systematic error in the drift measurement and in the mechanical construction. Results of measurements on prototypes are given. These indicate that a global precision of
σ ≲ 70 μm is achievable for large-area chambers.
Multiwire drift tubes with jet-cell geometry for muon detection at LHC Bagnaia, P.; Barberio, E.; Beker, H. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/1995, Letnik:
360, Številka:
1-2
Journal Article
Recenzirano
Recent results from test measurements with cosmic rays of jet-cell chamber prototypes, developed and studied for the μ detector of the ATLAS apparatus, are reported.
Test-beam performance of a tracking TRD prototype
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/1991
Journal Article
Heterocyclic compounds containing atoms of the elements such as nitrogen, sulfur and oxygen as ring members are commonly used in various fields of industry as analytical reagents, ligands, dyestuffs, ...pharmaceutical substances and bioindicators.
In this study 5-(Quinoline-2-ylidene)-1,3-diethyl-2-thiobarbituric acid have been synthesized via Knoevenagel condensation reaction, the product solutions were prepared 10 −3 − 10 −5 M in CHCI 3, THF, MeOH, DMF and DMSO. UV/VIS spectra recorded and then compared at each other. Absorbance of the solutions were measured at 200 – 300 nm. The maximum absorbance value increased and a new absorption appeared at 400 – 500 nm. The samples were excited at 337 nm in order to measure fluorescence. The maximum emission was observed in MeOH at 398 nm. These values increased by time; therefore, the samples were not stable in solution state.