Hip revision surgery in cases with previous multiple reconstructive procedures is a challenging procedure. A custom-made product could be useful to obtain good results. Four cases (2 men and 2 women) ...of acetabular customized Trabecular Titanium (TT) implants made by 3D printed technology were performed. The mean age at surgery was 51.5 years (range 25-72). Patients were reviewed clinically and radiographically at follow-up. Mean Harris Hip Score increased significantly from 13.9 (range 6.9-20.6) preoperatively to 75.8 (range 53.9-94) at last follow-up (mean 43.5, range: 36-59), showing an improvement in terms of both pain relief, function and joint mobility. Radiographically neither signs of instability, migration nor tilting were observed. TT custom-implant made by high performance of the 3D-printing technology, system modularity, and patient-specific surgical tools permitted good clinical results and an effective restoration of the biomechanical joint parameters in these complex revision cases.
Total knee replacement (TKR) is a widely used procedure for the treatment of post-traumatic arthritis. This type of solution has also been used recently for the treatment of acute fractures around ...the knee, particularly in joints that already presented arthritis before the trauma. In case of complex fractures of the distal femur especially in older or very compromised patients, the use of a segmental implant can be an option of treatment in order to obtain a quicker recovery of the patient allowing early mobilization and weight bearing. The purpose of this paper is to present our experience with segmental TKR in the treatment of complex fractures of the distal femur highlighting the main problems associated with these conditions and focusing on the indications, principles of technique, tips, tricks and pitfalls of this procedure.
In this clinical investigation, a new design with a progressive increased keel medialization according to the size was implanted. The cohort of patients was followed up for seven years.
From May 2012 ...to November 2012, we implanted 70 total knee arthroplasties in 69 patients. The mean age of the patients was 76.2 years. We followed up 56 patients for seven years; we evaluated the patients at six and 60 months after surgery by Patient Reported Outcome Measures score. During the seven-year follow-up, all patients were clinically re-evaluated using the Knee Society Score and the Forgotten Joint Score. All patients underwent a preoperative and postoperative radiographic investigation. At the last follow-up the presence of any radiolucency lines was checked using the Knee Society Total Knee Arthroplasty Radiographic Evaluation and Scoring System.
The patients defined the surgical results as excellent in 66% of the cases, very good in 23%, good in five percent. The analysis of the functional data at seven years, performed by administering the Forgotten Joint Score, showed average values of 70.4. The clinical analysis, performed through the Knee Society Score at the same follow-up, showed average values of 90.4. The seven-year radiological analysis revealed the presence of radiolucency lines in 20 implants. The sum of the line widths never exceeded the critical value of nine millimeters, always remaining below four millimeters. Only one patient was revised.
The results showed an excellent outcome of this design. The medialization of the tibial keel showed good bone fixation and component alignment at seven-year follow-up.
To evaluate the long-term efficacy and safety of Hymovis® in the symptomatic treatment of knee osteoarthritis (OA).
This is a prospective, multi-center, open label, phase III clinical study. Two ...intra-articular injections (3 mL) of Hymovis® (8 mg/mL HYADD® 4) were administered 1 week apart at the beginning of the study on day 0 and day 7 and after 6 months from baseline, on day 182 and 189. Follow-up assessment were conducted for 52 weeks. 50 subjects, > 40 years old, with knee OA, with clinical and radiological confirm, complain pain in the target knee were enrolled. The variables considered were: WOMAC questionnaire, Joint Space Width (JSW), OMERACT OARSI responder criteria, EQ-5D questionnaire, rescue medication consumption.
After the injections of Hymovis®, pain perceived by the patient when walking on a flat surface (WOMAC A1 score) significantly improves at the end of the study respect to the baseline. WOMAC stiffness, physical function and total score significantly improve during the study since 3 months after treatment, and it is maintained up to the end of the study (p < 0.001). By the x-ray analysis of knee, a radiological progression of OA was observed in the 26% of patients at the end of the study, while 88% of patients result to be responder to the therapy classified as per OMERACT-OARSI criteria. The EQ-5D weighted index increased significantly, against baseline, at each study time point (p < 0.001). Investigator's and patient's global assessment of the disease measured by the VAS both show a marked improvement in patient's health conditions.
Results from this study confirm that Hymovis® alleviate the knee pain since the first treatment cycle. The patients treated with two cycles of intra-articular injections of Hymovis® have a progressive pain reduction that is maintained up to one year after the treatment start with improve of all the scores considered in this study. Hymovis® is effective and safe in symptomatic treatment of painful knee OA.
This study evaluated single intra-articular injections of Hymovis MO.RE., a hyaluronic acid hexadecyl derivative (HYADD4-G), to manage post-traumatic or degenerative knee or ankle chondropathy in ...professional soccer players.
Twenty-five players affected by knee (n = 12) or ankle (n = 13) chondropathy were prospectively enrolled and treated by two single Hymovis MO.RE. (32 mg/4 ml) injections at the beginning of the football season (V0, baseline) and at mid-season (V1, 19-20 weeks thereafter), and were followed-up until the end of the season (V2, after further 19-20 weeks). Knee cases were evaluated using the 2000 IKDC knee subjective examination form and the modified Lysholm scoring system. Ankle cases were evaluated using the American Orthopaedic Foot Ankle Society (AOFAS) ankle-hindfoot score. Patients were also evaluated using a VAS Likert scale and a four-category scale recording both the patient's and the doctor's assessment on joint mobility in degrees and overall treatment efficacy. Adverse events, patient withdrawals and local reaction to injections were also assessed.
In knee patients, the 2000 IKDC subjective score improved from 46.8 ± 11.4 at V0 to 83.1 ± 12.5 at V2. Their modified Lysholm score improved from 58.8 ± 8.9 at V0 to 90.6 ± 8.3 at V2. In the ankle patients, the AOFAS score improved from 52.2 ± 5.6 at V0 to 96.4 ± 4.5 at V2. VAS Likert values and subjective evaluations improved at V1 and were maintained at V2. No side effects were recorded.
A single Hymovis MO.RE. (32 mg/4 ml) intra-articular injection, repeated after 19-20 weeks, may be a viable option to improve symptoms and function in professional soccer players suffering from knee and ankle chondropathy.
Robotic-assisted total knee arthroplasty (rTKA) has been developed to improve knee kinematics and functional outcomes, expedite recovery, and improve implants long-term survivorship. Robotic devices ...are classified into active, semi-active, and passive, based on their degree of freedom. Their capacity to provide increased accuracy in implants positioning with reduced radiographic outliers has been widely proved. However, these early advantages are yet to be associated with long-term survivorship. Moreover, multiple drawbacks are still encountered including a variable learning curve, increased setup and maintenance costs, and potential complications related to the surgical technique. Despite recent technologies applied to TKA have failed to prove substantial improvements, robotic-assisted surgery seems to be here to stay and revolutionize the field of TKA. To support its consistent usage on a daily basis, long-term results are still awaited, and further improvements are necessary to reduce the expenses related to it. Keywords: robotic total knee arthroplasty, knee alignment, accuracy, robot, survivorship, clinical outcomes
Purpose
This study aimed to highlight short- and medium-term outcomes of combined medial patello-femoral ligament (MPFL) reconstruction and anterior tibial tuberosity (ATT) transposition surgery in ...patients with recurrent patellar instability and different degrees of trochlear dysplasia.
Methods
Between January 2014 and May 2019, 25 patients with patellar instability underwent a surgical procedure combining the lowering/transposition of the ATT and the MPFL reconstruction. Each patient were preoperative assessed by Kujala score, International Knee Documentation Committee (IKDC), Tegner activity level scale. The assessment of instability predisposing factors was carried out with patellar height, tibial tuberosity-trochlear groove (TT-TG) distance, trochlear dysplasia, sulcus angle, patellar tilt and MPFL injuries. Functional outcomes were evaluated with Kujala, IKDC and Tegner scores at 3, 6 and 12 months after surgery.
Results
The average age of the patients was 20 years (range 13–43 years). Pre- operative Caton–Deschamps index was pathological in 10 (40%). Sulcus angle was elevated in 13 patients (52%) and TT-TG distance was irregular in 17 patients (68%). Trochlear dysplasia was present in 13 patients (9 type A, 3 type B, 1 type C according to Dejour’s Classification). No re-dislocation occurred during the follow-up. There was a significant increase in the Kujala, IKDC and Lysholm scores after 3, 6 and 12 months, and the results were compared for the different follow-up times and patient’s trochlear dysplasia degree.
Conclusion
This prospective observational longitudinal study identified good clinical outcomes in patients who underwent MPFL reconstruction and ATT transposition for patellar instability. Finally, the different risk factors for patellar instability examined, particularly the presence of trochlear dysplasia, did not significantly influence the final functional results, which range from good to excellent without re-dislocation episodes.
Background
Low back pain and sciatica represent a common disabling condition with a significant impact on the social, working and economic lives of patients. Transforaminal lumbar interbody fusion ...(TLIF) is a surgical procedure used in degenerative spine conditions. Several types of cages were used in the TLIF procedure.
Purpose
To determine whether there is a difference in terms of symptomatology improvement, return to daily activities and fusion rate between metal cages and polyetheretherketone (PEEK) cages.
Methods
We have retrospectively reviewed 40 patients who have undergone TLIF from October 2015 to May 2016. All patients were clinically evaluated with questionnaires and were assessed with CT scan and standing X-ray films of the full-length spine.
Results
We found no significant functional differences in the two groups. At 1-year follow-up, osteolysis was present in 50% of cases of the PEEK cages and in 10% cases of the metal cages. The degree of fusion at 1 year was evaluated as complete in 40% cases of the metal cages and 15% cases of the PEEK cages.
Conclusions
We have found a better fusion rate and prevalence of fusion in the group treated with metal cages, reflecting the well-known osteoinductive properties of titanium and tantalum.
•Carbonaceous implants do not cause appreciable artifacts on CT images.•Carbonaceous devices cause slight perturbation on TPS dose calculation accuracy.•A precise modeling and material assignment of ...the device should always be performed.•Multiple beams and avoidance structures are recommended with metallic implants.
The aim of this study was to evaluate the dosimetric impact caused by recently introduced carbon fiber reinforced polyetheretherketone (CF/PEEK) stabilization devices, in comparison with conventional titanium (Ti) implants, for post-operative particle therapy (PT).
As a first step, protons and carbon ions Spread-Out Bragg Peaks (SOBPs) were delivered to CF/PEEK and Ti screws. Transversal dose profiles were acquired with EBT3 films to evaluate beam perturbation. Effects on image quality and reconstruction artifacts were then investigated. CT scans of CF/PEEK and Ti implants were acquired according to our clinical protocol and Hounsfield Unit (HU) mean values were evaluated in three regions of interest. Implants and artifacts were then contoured in the sample CT scans, together with a target volume to simulate a spine tumor. Dose calculation accuracy was assessed by comparing optimized dose distributions with Monte Carlo simulations. In the end, the treatment plans of nine real patients (seven with CF/PEEK and two with Ti stabilization devices) were retrospectively analyzed to evaluate the dosimetric impact potentially occurring if improper management of the spine implant was carried out.
As expected, CF/PEEK screw caused a very slight beam perturbation in comparison with Ti ones, leading to a lower degree of dose degradation in case of contouring and/or set-up uncertainties. Furthermore, CF/PEEK devices did not determine appreciable HU artifacts on CT images thus improving image quality and, as a final result, dose calculation accuracy.
CF/PEEK spinal fixation devices resulted dosimetrically more suitable than commonly-used Ti implants for post-operative PT.