Abstract
More than three decades have passed since utilization of radiofrequency (RF) ablation in the treatment of cardiac arrhythmias. Although several limitations and challenges still exist, with ...improvements in catheter designs and delivery of energy the way we do RF ablation now is much safer and more efficient. This review article aims to give an overview on historical advances on RF ablation and challenges in performing safe and efficient ablation.
Graphical Abstract
Abstract Objectives The aims of this study were to: 1) use a novel method of late gadolinium enhancement (LGE) quantification that uses normalized intensity measures to confirm the association ...between LGE extent and atrial fibrillation (AF) recurrence following ablation; and 2) examine the presence of interaction and effect modification between LGE and AF persistence. Background Recurrent AF after catheter ablation has been reported to associate with the baseline extent of left atrial LGE on cardiac magnetic resonance. Traditional methods for measurement of intensity lack an objective threshold for quantification and interpatient comparisons of LGE. Methods The cohort included 165 participants (mean age 60.0 ± 10.2 years, 77% men, 57% with persistent AF) who underwent initial AF ablation. The association of baseline LGE extent with AF recurrence was examined using multivariable Cox proportional hazards models. Multiplicative and additive interactions between AF type and LGE extent were examined. Results During 10.2 ± 5.7 months of follow-up, 63 patients (38.2%) experienced AF recurrence. Baseline LGE extent was independently associated with AF recurrence after adjusting for confounders (hazard ratio: 1.5 per 10% increased LGE; p < 0.001). The hazard ratio for AF recurrence progressively increased as a function of LGE. The magnitude of association between LGE >35% and AF recurrence was greater among patients with persistent AF (hazard ratio: 6.5 p = 0.001 vs. 3.6 p = 0.001); however, there was no evidence for statistical interaction. Conclusions Regardless of AF persistence at baseline, participants with LGE ≤35% have favorable outcomes, whereas those with LGE >35% have a higher rate of AF recurrence in the first year after ablation. These findings suggest a role for: 1) patient selection for AF ablation using LGE extent; and 2) substrate modification in addition to pulmonary vein isolation in patients with LGE extent exceeding 35% of left atrial myocardium.
Left atrial flutter (LAFL) occurs in patients after atrial fibrillation ablation. Identification of optimal ablation targets to terminate LAFL remains challenging.
The purpose of this study was to ...use patient-specific models to simulate LAFL and predict optimal ablation targets using a novel approach based on flow network theory.
Late gadolinium-enhanced cardiac magnetic resonance scans from 10 patients with LAFL were used to construct atrial models incorporating fibrosis by investigators blinded to procedural findings. Rapid pacing was applied in silico to induce LAFL. In each LAFL, we represented reentrant wave propagation as an electric flow network and identified the "minimum cut" (MC), which was the smallest amount of tissue that separated the flow into 2 discontinuous components. In silico ablation was applied at MCs, and targets were compared to those that terminated LAFL during catheter ablation.
Patient-specific atrial models were successfully generated from patient scans. LAFL was induced in 7 of 10 models. Ablation of MCs terminated LAFL in 4 models and produced new, slower LAFL morphologies in the other 3. For the latter cases, flow analysis was repeated to identify MCs of emergent LAFLs. Ablation of these MCs terminated emergent LAFLs. The MC-based ablation lesions in simulations were similar in length and location to ablation targets that terminated LAFL during catheter ablation for these 7 patients.
Personalized atrial simulations can predict ablation targets for LAFL. These simulations provide a powerful tool for planning ablation procedures and may reduce procedural times and complications.
Previous studies suggest that magnetic resonance imaging with late gadolinium enhancement (LGE) may identify slowly conducting tissues in scar-related ventricular tachycardia (VT).
To test the ...feasibility of image-based simulation based on LGE to estimate ablation targets in VT.
We conducted a retrospective study in 13 patients who had preablation magnetic resonance imaging for scar-related VT ablation. We used image-based simulation to induce VT and estimate target regions according to the simulated VT circuit. The estimated target regions were coregistered with the LGE scar map and the ablation sites from the electroanatomical map in the standard ablation approach.
In image-based simulation, VT was inducible in 12 (92.3%) patients. All VTs showed macroreentrant propagation patterns, and the narrowest width of estimated target region that an ablation line should span to prevent VT recurrence was 5.0 ± 3.4 mm. Of 11 patients who underwent ablation, the results of image-based simulation and the standard approach were consistent in 9 (82%) patients, where ablation within the estimated target region was associated with acute success (n = 8) and ablation outside the estimated target region was associated with failure (n = 1). In 1 (9%) case, the results of image-based simulation and the standard approach were inconsistent, where ablation outside the estimated target region was associated with acute success.
The image-based simulation can be used to estimate potential ablation targets of scar-related VT. The image-based simulation may be a powerful noninvasive tool for preprocedural planning of ablation procedures to potentially reduce the procedure time and complication rates.
Ventricular Arrhythmias in Cardiac Sarcoidosis Okada, David R; Smith, John; Derakhshan, Arsalan ...
Circulation (New York, N.Y.),
2018-September-18, Letnik:
138, Številka:
12
Journal Article
Recenzirano
Odprti dostop
The diagnosis of cardiac sarcoidosis (CS), especially in cases where there is limited or no extracardiac involvement, is challenging. Patients with CS are at increased risk of ventricular arrhythmias ...and sudden cardiac death. Several techniques for risk stratification for sudden cardiac death have been proposed in this population, including advanced cardiac imaging and electrophysiology study. Clinical ventricular arrhythmias in patients with CS may be treated with immunosuppressant therapy, antiarrhythmic drugs, catheter ablation, or implantable cardioverter-defibrillator placement. This article will provide an update on techniques for diagnosing CS, risk stratifying patients with CS for sudden cardiac death, and treating patients with CS with ventricular arrhythmias, focusing on evidence that has become available since publication of the 2014 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Management of Arrhythmias Associated With Cardiac Sarcoidosis.
Despite the revolutionary advancements in the past 3 decades in the treatment of ventricular tachyarrhythmias with device-based therapy, sudden cardiac death (SCD) remains an enormous public health ...burden. Survivors of SCD are generally at high risk for recurrent events. The clinical management of such patients requires a multidisciplinary approach from postresuscitative care to a thorough cardiovascular investigation in an attempt to identify the underlying substrate, with potential to eliminate or modify the triggers through catheter ablation and ultimately an implantable cardioverter-defibrillator (ICD) for prompt treatment of recurrences in those at risk. Early recognition of low left ventricular ejection fraction as a strong predictor of death and association of ventricular arrhythmias with sudden death led to significant investigation with antiarrhythmic drugs. The lack of efficacy and the proarrhythmic effects of drugs catalyzed the development and investigation of the ICD through several major clinical trials that proved the efficacy of ICD as a bedrock tool to detect and promptly treat life-threatening arrhythmias. The ICD therapy is routinely used for primary prevention of SCD in patients with cardiomyopathy and high risk inherited arrhythmic conditions and secondary prevention in survivors of sudden cardiac arrest. This compendium will review the clinical management of those surviving SCD and discuss landmark studies of antiarrhythmic drugs, ICD, and cardiac resynchronization therapy in the primary and secondary prevention of SCD.
A total of 1509 patients who had legacy pacemakers or defibrillators underwent 2103 MRIs according to a prespecified safety protocol. No long-term clinically significant adverse events were reported.
Atrial fibrillation (AF) is an important cause of stroke. Given the morbidity and mortality associated with stroke, the risk stratification of patients based on left atrial appendage (LAA) ...characteristics is of great interest.
To explore the association between LAA morphology and LAA characteristics including the extent of trabeculations, orifice diameter, and length with prevalent stroke in a large cohort of patients with drug refractory AF who underwent AF ablation to develop mechanistic insight regarding the risk of stroke.
An institutional cohort of 1063 patients referred for AF ablation from 2003 to 2012 was reviewed to identify patients that underwent preprocedural cardiac computed tomography (CT). LAA morphology was characterized as chicken wing, cactus, windsock, or cauliflower by using previously reported methodology. Left atrial size and LAA trabeculations, morphology, orifice diameter, and length were compared between patients with prevalent stroke and patients without prevalent stroke.
Of 678 patients with CT images, 65 (10%) had prior stroke or transient ischemic attack. In univariate analyses, prevalent heart failure (7.7% in cases vs 2.8% in controls; P = .033), smaller LAA orifice (2.26 ± 0.52 cm vs 2.78 ± 0.71 cm ; P < .001), shorter LAA length (5.06 ± 1.17 cm vs 5.61 ± 1.17 cm; P < .001), and extensive LAA trabeculations (27.7% vs 14.4%; P = .019) were associated with stroke. LAA morphologies were unassociated with stroke risk. In multivariable analysis, smaller LAA orifice diameter and extensive LAA trabeculations remained independently associated with thromboembolic events.
The extent of LAA trabeculations and smaller LAA orifice diameter are associated with prevalent stroke and may mediate the previously described association of cauliflower LAA morphology with stroke.
Objectives This study was designed to assess the risk of significant bleeding complications in patients receiving antiplatelet or anticoagulation medications at the time of implantable ...cardioverter-defibrillator (ICD) device implantation. Background Periprocedural management of antiplatelet or anticoagulation therapy at the time of device implantation remains controversial. Methods We performed a retrospective chart review of bleeding complications in all patients undergoing ICD or pacemaker implantation from August 2004 to August 2007. Aspirin or clopidogrel use was defined as taken within 5 days of the procedure. A significant bleeding complication was defined as need for pocket exploration or blood transfusion; hematoma requiring pressure dressing or change in anticoagulation therapy; or prolonged hospitalization. Results Of the 1,388 device implantations, 71 had bleeding complications (5.1%). Compared with controls not taking antiplatelet agents (n = 255), the combination of aspirin and clopidogrel (n = 139) significantly increased bleeding risk (7.2% vs. 1.6%; p = 0.004). In patients taking aspirin alone (n = 536), bleeding risk was marginally higher than it was for patients taking no antiplatelet agents (3.9% vs. 1.6%, p = 0.078). The use of periprocedural heparin (n = 154) markedly increased risk of bleeding when compared with holding warfarin until the international normalized ratio (INR) was normal (n = 258; 14.3% vs. 4.3%; p < 0.001) and compared with patients receiving no anticoagulation therapy (14.3% vs.1.6%; p < 0.0001). There was no statistical difference in bleeding risk between patients continued on warfarin with an INR ≥1.5 (n = 46) and patients who had warfarin withheld until the INR was normal (n = 258; 6.5% vs. 4.3%; p = 0.50). Conclusions Dual antiplatelet therapy and periprocedural heparin significantly increase the risk of bleeding complications at the time of pacemaker or ICD implantation.
The measurement of late gadolinium-enhanced magnetic resonance imaging (LGE-MRI) intensity in arbitrary units limits the objectivity of thresholds for focal scar detection and interpatient ...comparisons of scar burden.
To develop and validate a normalized measure, the image intensity ratio (IIR), for the assessment of left atrial (LA) scar on LGE-MRI.
Electrocardiogram- and respiratory-gated 1.5 Tesla LGE-MRI was performed in 75 patients (75% men; 62 ± 8 years) before atrial fibrillation ablation. The local IIR was defined as LA myocardial signal intensity for each of the 20 sectors on contiguous axial image planes divided by the mean LA blood pool image intensity. Intracardiac point-by-point sampled electroanatomic map points were coregistered with the corresponding image sectors.
The average bipolar voltage for all 8153 electroanatomic map points was 0.9 ± 1.1 mV. In a mixed effects model accounting for within patient clustering, and adjusting for age, LA volume, mass, body mass index, sex, CHA2DS2-VASc score, atrial fibrillation type, history of previous ablations, and contrast delay time, each unit increase in local IIR was associated with 91.3% decrease in bipolar LA voltage (P < .001). Local IIR thresholds of >0.97 and >1.61 corresponded to bipolar voltage <0.5 and <0.1 mV, respectively.
Normalization of LGE-MRI intensity by the mean blood pool intensity results in a metric that is closely associated with intracardiac voltage as a surrogate of atrial fibrosis.