The so-coined fourth paradigm in science has reached the sensing area, with the use of machine learning (ML) toward data-driven improvements in sensitivity, reproducibility, and accuracy, along with ...the determination of multiple targets from a single measurement using multi-output regression models. Particularly, the use of supervised ML models trained on large data sets produced by electrical and electrochemical bio/sensors has emerged as an impacting trend in the literature by allowing accurate analyses even in the presence of usual issues such as electrode fouling, poor signal-to-noise ratio, chemical interferences, and matrix effects. In this trend article, apart from an outlook for the coming years, we present examples from the literature that demonstrate how helpful ML algorithms can be for dispensing the adoption of experimental methods to address the aforesaid interfering issues, ultimately contributing to translate testing technologies into on-site, practical, and daily applications.
Graphical Abstract
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data ...from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range
5
×
10
-
3
eV
2
≲
Δ
m
41
2
≲
3
×
10
-
1
eV
2
for mixing angles down to
sin
2
2
θ
14
≳
0.02
. No significant disappearance additionally to the conventional disappearance related to
θ
13
is observed and correspondingly exclusion bounds on the sterile mixing parameter
θ
14
as a function of
Δ
m
41
2
are obtained.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The measurement of neutrino mass ordering (MO) is a fundamental element for the understanding of leptonic flavour sector of the Standard Model of Particle Physics. Its determination relies on the ...precise measurement of Formula: see text and Formula: see text using either neutrino vacuum oscillations, such as the ones studied by medium baseline reactor experiments, or matter effect modified oscillations such as those manifesting in long-baseline neutrino beams (LBFormula: see textB) or atmospheric neutrino experiments. Despite existing MO indication today, a fully resolved MO measurement (Formula: see text) is most likely to await for the next generation of neutrino experiments: JUNO, whose stand-alone sensitivity is Formula: see text, or LBFormula: see textB experiments (DUNE and Hyper-Kamiokande). Upcoming atmospheric neutrino experiments are also expected to provide precious information. In this work, we study the possible context for the earliest full MO resolution. A firm resolution is possible even before 2028, exploiting mainly vacuum oscillation, upon the combination of JUNO and the current generation of LBFormula: see textB experiments (NOvA and T2K). This opportunity is possible thanks to a powerful synergy boosting the overall sensitivity where the sub-percent precision of Formula: see text by LBFormula: see textB experiments is found to be the leading order term for the MO earliest discovery. We also found that the comparison between matter and vacuum driven oscillation results enables unique discovery potential for physics beyond the Standard Model.
Low-energy physics in neutrino LArTPCs Andringa, S; Asaadi, J; Bezerra, J T C ...
Journal of physics. G, Nuclear and particle physics,
01/2023, Letnik:
50, Številka:
3
Journal Article
Recenzirano
Odprti dostop
Abstract
In this paper, we review scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber ...(LArTPC) neutrino detectors. LArTPC neutrino detectors designed for performing precise long-baseline oscillation measurements with GeV-scale accelerator neutrino beams also have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. In addition, low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final-states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. New physics signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of Beyond the Standard Model scenarios accessible in LArTPC-based searches. A variety of experimental and theory-related challenges remain to realizing this full range of potential benefits. Neutrino interaction cross-sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood, and improved theory and experimental measurements are needed; pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for improving this understanding. There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways. Novel concepts for future LArTPC technology that enhance low-energy capabilities should also be explored to help address these challenges.
The aim of this study was to evaluate the anti-erosive effect of solutions containing sodium fluoride (F: 225 ppm F – ), stannous chloride (Sn: 800 ppm Sn2+), and some film-forming polymers (Gantrez: ...Poly methylvinylether-alt-maleic anhydride; PGA: propylene glycol alginate; Plasdone: polyvinylpyrrolidone; and CMC: carboxymethylcellulose). Solutions were tested in an erosion-remineralization cycling model, using enamel and dentin specimens ( n = 10, for each substrate). Distilled water was the negative control. Cycling consisted of 120 min immersion in human saliva, 5 min in 0.3% citric acid solution, and 120 min of exposure to human saliva, 4×/day, for 5 days. Treatment with solutions (pH = 4.5) was carried out 2×/day, for 2 min. Surface loss (SL) was evaluated with optical profilometry. Zeta potential of hydroxyapatite crystals was determined after treatment with the solutions. Data were statistically analyzed (α = 0.05). For enamel, all polymers showed significantly lower SL (in µm) than the control (11.09 ± 0.94), except PGA (10.15 ± 1.25). PGA significantly improved the protective effect of F (4.24 ± 0.97 vs. 5.64 ± 1.60, respectively). None of the polymers increased the protection of F+Sn (5.13 ± 0.78). For dentin, only Gantrez (11.40 ± 0.97) significantly reduced SL when compared with the negative control (12.76 ± 0.75). No polymer was able to enhance the effect of F (6.28 ± 1.90) or F+Sn (7.21 ± 1.13). All fluoridated solutions demonstrated significantly lower SL values than the control for both substrates. Treatment of hydroxyapatite nanoparticles with all solutions resulted in more negative zeta potentials than those of the control, except Plasdone, PGA, and F+Sn+PGA, the latter two presenting the opposite effect. In conclusion, Gantrez, Plasdone, and CMC exhibited an anti-erosive effect on enamel. PGA increased the protection of F. For dentin, only Gantrez reduced erosion.
Visceral adipose tissue (VAT) is associated with various metabolic disorders, and adipokines, secreted by adipose tissue, are involved in their pathogenesis. This study investigated associations ...between VAT/subcutaneous adipose tissue (SAT) ratio, inflammatory markers, and cardiovascular (CV) risk-score in adults. Plasma levels of adipokines, plasma lipid profile, blood pressure, and body composition (using dual-emission x-ray absorptiometry) were determined. CV risk-score based on the American College of Cardiology and the American Heart Association (ACC/AHA) score was calculated in a sample of 309 Brazilian civil servants aged <60 years. Participants' VAT/SAT ratio were categorized into quartiles. Among males, plasma leptin (2.8 ng/mL) and C reactive protein (CRP) (0.2 mg/dL) (P<0.05) levels were higher at P75 and P50 than P5, and the highest calculated CV risk-score was observed at P75 (7.1%). Among females, higher plasma adiponectin levels were observed at P25 (54.3 ng/mL) compared with P75 (36 ng/mL) (P<0.05). Higher plasma CRP levels were observed at P75 (0.4 mg/dL) compared with P5 (0.1 mg/dL) (P<0.05). Higher CV risk-score was observed at P75 (2.0%) compared with P5 (0.7%). In both sexes, VAT and VAT/SAT ratio were directly associated with plasma leptin, CRP, and CV risk-score, and inversely associated with adiponectin; SAT was directly associated with plasma leptin and CRP (P<0.01); interleukin (IL)-10 and CRP were directly associated with adiponectin and leptin, respectively (P<0.05). Among men only, IL-10 (inversely) and CRP (directly) were associated with CV risk-score (P=0.02). Our results strengthened the relevance of the VAT/SAT ratio in cardiovascular risk.
Abstract
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent ...volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.
The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. This analysis uses events ...with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5σ.