We present a search for the direct production of a light pseudoscalar a decaying into two photons with the Belle II detector at the SuperKEKB collider. We search for the process eþe- → γa, a → γγ in ...the mass range 0.2 < ma < 9.7 GeV=c2 using data corresponding to an integrated luminosity of ð445 3Þ pb-1. Light pseudoscalars interacting predominantly with standard model gauge bosons (so-called axionlike particles or ALPs) are frequently postulated in extensions of the standard model. We find no evidence for ALPs and set 95% confidence level upper limits on the coupling strength gaγγ of ALPs to photons at the level of 10-3 GeV-1. The limits are the most restrictive to date for 0.2 < ma < 1 GeV=c2 .
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X0 depth and 180×180mm2 transverse ...dimensions was constructed, consisting of 2160 individually read out 10×45×3mm3 scintillator strips. This prototype was tested using electrons of 2–32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12.5±0.1(stat.)±0.4(syst.))%∕EGeV⊕(1.2±0.1(stat.)−0.7+0.6(syst.))%, where the uncertainties correspond to statistical and systematic sources, respectively.
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity ...scintillator-silicon photomultiplier calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the average energy response, resolution, and longitudinal shower profiles. Two techniques are applied to reconstruct the initial particle energy from the measured energy depositions; a standard energy reconstruction which is linear in the measured depositions and a software compensation technique based on reweighting individually measured depositions according to their hit energy. The results are compared to predictions of the GEANT 4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
The high granularity of the CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) provides the capability to reveal the track segments present in hadronic showers. These segments are then used as a tool ...to probe the behaviour of the active layers in situ, to better reconstruct the energy of these hadronic showers and also to distinguish them from electromagnetic ones. In addition, the comparison of these track segments in data and the simulation helps to discriminate among the different shower models used in the simulation. To extract the track segments in the showers recorded in the SDHCAL, a Hough Transform is used after being adapted to the presence of the dense core of the hadronic showers and the SDHCAL active medium structure.
The CALICE Semi-Digital Hadronic Calorimeter technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This ...technology is one of the two options proposed for the hadronic calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. This paper presents the SDHCAL prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and ...protons with initial momenta in the range of 10-80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from GEANT4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity ...scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
From April to July 2018, a data sample at the peak energy of the Υ(4S) resonance was collected with the Belle II detector at the SuperKEKB electron-positron collider. This is the first data sample of ...the Belle II experiment. Using Bhabha and digamma events, we measure the integrated luminosity of the data sample to be (496.3±0.3±3.0) pb-1), where the first uncertainty is statistical and the second is systematic. This work provides a basis for future luminosity measurements at Belle II.
From April to July 2018, a data sample at the peak energy of the resonance was collected with the Belle II detector at the SuperKEKB electron-positron collider. This is the first data sample of the ...Belle II experiment. Using Bhabha and digamma events, we measure the integrated luminosity of the data sample to be ( , where the first uncertainty is statistical and the second is systematic. This work provides a basis for future luminosity measurements at Belle II.
The Belle II Physics Book Urquijo, P.; Bell, G.; Bigi, I. I. ...
Progress of theoretical and experimental physics,
12/2019, Letnik:
2019, Številka:
12
Journal Article
Recenzirano
Odprti dostop
We present the physics program of the Belle II experiment, located on the intensity frontier SuperKEKB e+e- collider. Belle II collected its first collisions in 2018, and is expected to operate for ...the next decade. It is anticipated to collect 50/ab of collision data over its lifetime. This book is the outcome of a joint effort of Belle II collaborators and theorists through the Belle II theory interface platform (B2TiP), an effort that commenced in 2014. The aim of B2TiP was to elucidate the potential impacts of the Belle II program, which includes a wide scope of physics topics: B physics, charm, tau, quarkonium, electroweak precision measurements and dark sector searches. It is composed of nine working groups (WGs), which are coordinated by teams of theorist and experimentalists conveners: Semileptonic and leptonic B decays, Radiative and Electroweak penguins, φ1 and φ2 (time-dependent CP violation) measurements, φ3 measurements, Charmless hadronic B decay, Charm, Quarkonium(like), tau and low-multiplicity processes, new physics and global fit analyses. This book highlights "golden- and silver-channels", i.e. those that would have the highest potential impact in the field. Theorists scrutinised the role of those measurements and estimated the respective theoretical uncertainties, achievable now as well as prospects for the future. Experimentalists investigated the expected improvements with the large dataset expected from Belle II, taking into account improved performance from the upgraded detector.