Background Breast cancer (BrCa) is a predominant malignancy, with metastasis occurring in one in eight patients, nearly half of which target the bone, leading to serious complications such as pain, ...fractures, and compromised mobility. Structural rigidity, crucial for bone strength, becomes compromised with osteolytic lesions, highlighting the vulnerability and increased fracture risk in affected areas. Historically, two-dimensional radiographs have been employed to predict these fracture risks; however, their limitations in capturing the three-dimensional structural and material changes in bone have raised concerns. Recent advances in CT-based Structural Rigidity Analysis (CTRA), offer a promising, more accurate non-invasive 3D approach. This study aims to assess the efficacy of CTRA in monitoring osteolytic lesions' progression and response to therapy, suggesting its potential superiority over existing methodologies in guiding treatment strategies. Methods Twenty-seven female nude rats underwent femoral intra-medullary inoculation with MDA-MB-231 human breast cancer cells or saline control. They were divided into Control, Cancer Control, Ibandronate, and Paclitaxel groups. Osteolytic progression was monitored weekly using biplanar radiography, quantitative computed tomography (QCT), and dual-energy X-ray absorptiometry (DEXA). CTRA was employed to predict fracture risk, normalized using the contralateral femur. Statistical analyses, including Kruskal-Wallis and ANOVA, assessed differences in outcomes among groups and over time. Results Biplanar radiographs showed treatment benefits over time; however, only certain time-specific differences between the Control and other treatment groups were discernible. Notably, observer subjectivity in X-ray scoring became evident, with significant inter-operator variations. DEXA measurements for metaphyseal Bone Mineral Content (BMC) did not exhibit notable differences between groups. Although diaphyseal BMC highlighted some variance, it did not reveal significant differences between treatments at specific time points, suggesting a limited ability for DEXA to differentiate between treatment effects. In contrast, the CTRA consistently demonstrated variations across different treatments, effectively capturing bone rigidity changes over time, and the axial- (EA), bending- (EI), and torsional rigidity (GJ) outcomes from the CTRA method successfully distinguished differences among treatments at specific time points. Conclusion Traditional approaches, such as biplanar radiographs and DEXA, have exhibited inherent limitations, notably observer bias and time-specific inefficacies. Our study accentuates the capability of CTRA in capturing real-time, progressive changes in bone structure, with the potential to predict fractures more accurately and provide a more objective analysis. Ultimately, this innovative approach may bridge the existing gap in clinical guidelines, ushering in enhanced Clinical Decision Support Tool (CDST) for both surgical and non-surgical treatments. Keywords: Breast cancer, Metastasis, Structural rigidity, Osteolytic lesions, CT-based structural rigidity analysis, CTRA, DEXA, Fracture risk, Clinical decision support tool, CDS tool
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The National HIV Strategic Plan for the US recommends HIV screening in emergency departments (EDs). The most effective approach to ED-based HIV screening remains unknown.
To compare strategies for ...HIV screening when integrated into usual ED practice.
This randomized clinical trial included patients visiting EDs at 4 US urban hospitals between April 2014 and January 2016. Patients included were ages 16 years or older, not critically ill or mentally altered, not known to have an HIV positive status, and with an anticipated length of stay 30 minutes or longer. Data were analyzed through March 2021.
Consecutive patients underwent concealed randomization to either nontargeted screening, enhanced targeted screening using a quantitative HIV risk prediction tool, or traditional targeted screening as adapted from the Centers for Disease Control and Prevention. Screening was integrated into clinical practice using opt-out consent and fourth-generation antigen-antibody assays.
New HIV diagnoses using intention-to-treat analysis, absolute differences, and risk ratios (RRs).
A total of 76 561 patient visits were randomized; median (interquartile range) age was 40 (28-54) years, 34 807 patients (51.2%) were women, and 26 776 (39.4%) were Black, 22 131 (32.6%) non-Hispanic White, and 14 542 (21.4%) Hispanic. A total of 25 469 were randomized to nontargeted screening; 25 453, enhanced targeted screening; and 25 639, traditional targeted screening. Of the nontargeted group, 6744 participants (26.5%) completed testing and 10 (0.15%) were newly diagnosed; of the enhanced targeted group, 13 883 participants (54.5%) met risk criteria, 4488 (32.3%) completed testing, and 7 (0.16%) were newly diagnosed; and of the traditional targeted group, 7099 participants (27.7%) met risk criteria, 3173 (44.7%) completed testing, and 7 (0.22%) were newly diagnosed. When compared with nontargeted screening, targeted strategies were not associated with a higher rate of new diagnoses (enhanced targeted and traditional targeted combined: difference, -0.01%; 95% CI, -0.04% to 0.02%; RR, 0.7; 95% CI, 0.30 to 1.56; P = .38; and enhanced targeted only: difference, -0.01%; 95% CI, -0.04% to 0.02%; RR, 0.70; 95% CI, 0.27 to 1.84; P = .47).
Targeted HIV screening was not superior to nontargeted HIV screening in the ED. Nontargeted screening resulted in significantly more tests performed, although all strategies identified relatively low numbers of new HIV diagnoses.
ClinicalTrials.gov Identifier: NCT01781949.
Abstract Transvenous cardiac pacemaker placement is an important and complex emergency procedure. Given that placement of a transvenous pacemaker is a relatively uncommon occurrence, maintaining ...procedural competency can be a considerable challenge. Utilizing principles of cognitive load theory, this educational resource provides a means for learning the procedure and maintaining clinical competence. This is accomplished through multiple learning activities including a procedural slide set, first-person point-of-view walkthrough video, and a procedural checklist, which allow for self-directed study and quick reference. This resource is clinically significant for practicing physicians, residents, and medical students attempting to gain or maintain competency with transvenous cardiac pacemaker placement.