Tumor-specific fluorescent imaging agents are moving towards the clinic, supporting surgeons with real-time intraoperative feedback about tumor locations. The epithelial cell adhesion molecule ...(EpCAM) is considered as one of the most promising tumor-specific proteins due its high overexpression on epithelial-derived cancers. This study describes the development and evaluation of EpCAM-F800, a novel fluorescent anti-EpCAM antibody fragment, for intraoperative tumor imaging. Fab production, conjugation to the fluorophore IRDye 800CW, and binding capacities were determined and validated using HPLC, spectrophotometry and cell-based assays. In vivo, dose escalation-, blocking-, pharmacokinetic- and biodistribution studies (using both fluorescence and radioactivity) were performed, next to imaging of clinically relevant orthotopic xenografts for breast and colorectal cancer. EpCAM-F800 targets EpCAM with high specificity in vitro, which was validated using in vivo blocking experiments with a 10x higher dose of unlabeled Fab. The optimal dose range for fluorescence tumor detection in mice was 1–5 nmol (52–260 μg), which corresponds to a human equivalent dose of 0.2–0.8 mg/kg. Biodistribution showed high accumulation of EpCAM-F800 in tumors and metabolizing organs. Breast and colorectal tumors could clearly be visualized within 8 h post-injection and up to 96 h, while the agent already showed homogenous tumor distribution within 4 h. The blood half-life was 4.5 h. This study describes the development and evaluation of a novel EpCAM-targeting agent and the feasibility to visualize breast and colorectal tumors by fluorescence imaging during resections. EpCAM-F800 will be translated for clinical use, considering its abundance in a broad range of tumor types.
•EpCAM-F800 is a fluorescent anti-EpCAM Fab for intraoperative tumor imaging.•EpCAM-F800 targets EpCAM with high specificity in vitro and in vivo .•Breast and colorectal tumors could be clearly detected using EpCAM-F800 .•The optimal dose range for fluorescence tumor detection in mice was 1–5 nmol.•EpCAM-F800 will be translated for clinical use and enter the clinic shortly.
AIM: To investigate feasibility and accuracy of nearinfrared fluorescence imaging using indocyanine green: nanocolloid for sentinel lymph node(SLN) detection in gastric cancer.METHODS: A prospective, ...single-institution, phaseI feasibility trial was conducted. Patients suffering from gastric cancer and planned for gastrectomy were included. During surgery, a subserosal injection of 1.6 m L ICG:Nanocoll was administered around the tumor. NIR fluorescence imaging of the abdominal cavity was performed using the Mini-FLARE? NIR fluorescence imaging system. Lymphatic pathways and SLNs were visualized. Of every detected SLN, the corresponding lymph node station, signal-to-background ratio and histopathological diagnosis was determined. Patients underwent standard-of-care gastrectomy. Detected SLNs outside the standard dissection planes were also resected and evaluated.RESULTS: Twenty-six patients were enrolled. Four patients were excluded because distant metastases were found during surgery or due to technical failure of the injection. In 21 of the remaining 22 patients, at least 1 SLN was detected by NIR Fluorescence imaging(mean 3.1 SLNs; range 1-6). In 8 of the 21 patients, tumor-positive LNs were found. Overall accuracy of the technique was 90%(70%-99%; 95%CI), which decreased by higher p T-stage(100%, 100%, 100%, 90%, 0% for respectively Tx, T1, T2, T3, T4 tumors). All NIR-negative SLNs were completely effaced by tumor. Mean fluorescence signal-to-background ratio of SLNs was 4.4(range 1.4-19.8). In 8 of the 21 patients, SLNs outside the standard resection plane were identified, that contained malignant cells in 2 patients.CONCLUSION: This study shows successful use of ICG:Nanocoll as lymphatic tracer for SLN detection in gastric cancer. Moreover, tumor-containing LNs outside the standard dissection planes were identified.
Fluorescence-guided surgery can provide surgeons with an imaging tool for real-time intraoperative tumor detection. SGM-101, an anti-CEA antibody labelled with a fluorescent dye, is a tumor-specific ...imaging agent that can aid in improving detection and complete resection for CEA-positive tumors. In this study, the performance of SGM-101 for the detection of colorectal and pancreatic liver metastases was investigated.
In this open-label, non-randomized, single-arm pilot study, patients were included with liver metastases from colorectal origin and intraoperatively detected liver metastases from pancreatic origin (during planned pancreatic surgery). SGM-101 was administered two to four days before the scheduled surgery as a single intravenous injection. Intraoperative fluorescence imaging was performed using the Quest Spectrum® imaging system. The performance of SGM-101 was assessed by measuring the intraoperative fluorescence signal and comparing this to histopathology.
A total of 19 lesions were found in 11 patients, which were all suspected as malignant in white light and subsequent fluorescence inspection. Seventeen lesions were malignant with a mean tumor-to-background ratio of 1.7. The remaining two lesions were false-positives as proven by histology.
CEA-targeted fluorescence-guided intraoperative tumor detection with SGM-101 is feasible for the detection of colorectal and pancreatic liver metastases.
Abstract Background Several studies demonstrated that intraoperative near-infrared fluorescence (NIRF) imaging using indocyanine green (ICG) identifies (sub)capsular colorectal liver metastases ...(CRLM) missed by other techniques. It is unclear if this results in any survival benefit. This study evaluates long-term follow-up after NIRF-guided resection of CRLM using ICG. Methods First, patients undergoing resection of CRLM with or without NIRF imaging were analyzed retrospectively. Perioperative details, liver-specific recurrence-free interval and overall survival were compared. Second, the prognosis of patients in whom additional metastases were identified solely by NIRF was studied. Results Eighty-six patients underwent resection with NIRF imaging and 87 without. In significantly more patients of the NIRF imaging cohort additional metastases were identified during surgery (25% vs. 13%, p = 0.04). Tumors identified solely by NIRF imaging were significantly smaller compared to additional metastases identified also by inspection, palpation or intraoperative ultrasound (3.2 ± 1.8 mm vs. 7.4 ± 2.6 mm, p < 0.001). Liver-specific recurrence-free survival at 4 years was 47% with NIRF imaging and 39% without (hazard ratio at multivariate analysis 0.73, 95% CI 0.42–1.28, p = 0.28). Overall survival at 4 years was 62% and 59%, respectively ( p = 0.79). No liver recurrences occurred within 3 years follow-up in 52% of patients in whom additional metastases were resected based on only NIRF imaging. Conclusions This study suggests that NIRF imaging identifies significantly more and smaller tumors during resection of CRLM, preventing recurrences in a subset of patients. Given its safety profile and low expense, routine use can be considered until tumor targeting fluorescent tracers are clinically available.
Detection and resection of all malignant lesions is pivotal in staging and cytoreductive surgery (CRS) of endometrial cancer (EC). Intraoperative EC detection could be enhanced using OTL-38, a ...fluorescent-labelled folate receptor-α (FRα) targeted imaging agent. The objectives of this study were to investigate which subgroups of high-risk EC patients express FRα and assess feasibility of intraoperative EC detection using OTL-38.
FRα expression on TMA was significantly correlated with tumor type (
< 0.01). Eighty-two percent of serous and clear cell carcinomas showed FRα expression. Four patients were enrolled in the clinical study. Using fluorescence imaging all omental (
= 3) and lymph node (LN) metastases (
= 16) could be clearly identified, including one otherwise undetected omental metastasis. However, false-positive fluorescence was identified in 17/50 non-metastatic LNs, caused by OTL-38 targeting of FRβ, expressed by tumor-associated activated macrophages.
This study describes high FRα expression in serous and clear cell EC and demonstrates the first experience of intraoperative FRα-targeted tumor detection in patients with these subtypes of EC. Although all metastases could be clearly identified using OTL-38, the role of tumor-associated macrophages should be further evaluated.
Immunohistochemical (IHC) staining of FRα expression was performed on tissue micro arrays (TMA) of 116 patients with high-risk EC features. Patients with either serous or clear cell EC, planned for staging or CRS, were eligible for inclusion in the clinical study and received an intravenous dose of 0.0125 mg/kg OTL-38, 2-3 hours prior to surgery. Resected lesions, identified by standard-of-care and/or fluorescence imaging, were histopathologically assessed for FRα and tumor status.
Folate receptor alpha (FRα) is known to be upregulated in a variety of cancers, including non-small cell lung cancer (NSCLC) and breast cancer. To ensure reliable implementation of diagnostic- and ...therapeutic agents, concordance of FRα expression between biopsy, primary tumor and metastases is important. Using immunohistochemistry (Mab 26B3.F2) these concordances were investigated in 60 NSCLC and 40 breast cancer patients. False positivity of FRα expression on breast and lung cancer biopsies was limited to less than 5%. In NSCLC, FRα expression was shown in 21/34 adenocarcinomas and 4/26 squamous cell carcinomas (SCC). Concordance of FRα expression between biopsy and primary tumor was achieved in respectively 83% and 91% of adenocarcinomas and SCCs. Approximately 80% of all local and distant metastases of NSCLC patients showed concordant FRα expression as their corresponding primary tumor. In breast cancer, FRα positivity was shown in 12/40 biopsies, 20/40 lumpectomies and 6/20 LN metastases, with concordance of 68% between biopsy and primary tumor and 60% between primary tumor and LN metastases. In conclusion, this study shows high concordance rates of FRα expression between biopsies and metastases compared to primary NSCLC and breast cancers, underscoring the applicability of FRα-targeted agents in these patients.
Intraoperative identification of rectal cancer (RC) can be challenging, especially because of fibrosis after treatment with preoperative chemo- and radiotherapy (CRT). Tumor-targeted fluorescence ...imaging can enhance the contrast between tumor and normal tissue during surgery. Promising targets for RC imaging are carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EpCAM) and the tyrosine-kinase receptor Met (c-Met). The effect of CRT on their expression determines their applicability for imaging. Therefore, we investigated whether CRT modifies expression patterns in tumors, lymph node (LN) metastases and adjacent normal rectal tissues.
Preoperative biopsies, primary tumor specimens and metastatic LNs were collected from 38 RC patients who did not receive CRT (cohort 1) and 34 patients who did (cohort 2). CEA, EpCAM and c-Met expression was determined using immunohistochemical staining and was semiquantified by a total immunostaining score (TIS), consisting of the percentage and intensity of stained tumor cells (0-12).
In both cohorts CEA, EpCAM and c-Met were significantly highly expressed in >60% of tumor tissues compared with adjacent normal epithelium (T/N ratio,
<0.01). EpCAM showed the most homogenous expression in tumors, whereas CEA showed the highest T/N ratio. Most importantly, CEA and EpCAM expression did not significantly change in normal or neoplastic RC tissue after CRT, whereas levels of c-Met changed (
=0.02). Tissues of eight patients with a pathological complete response after CRT showed expression of all biomarkers with TIS close to normal epithelium.
Histological evaluation shows that CEA, EpCAM and c-Met are suitable targets for RC imaging, because all three are significantly enhanced in cancer tissue from primary tumors or LN metastases compared with normal adjacent tissue. Furthermore, the expression of CEA and EpCAM is not significantly changed after CRT. These data underscore the applicability of c-Met and especially, CEA and EpCAM as targets for image-guided RC surgery, both before and after CRT.
Multiple endocrine neoplasia type 1 syndrome can feature pancreatic neuroendocrine lesions that have the potential to degenerate into malignancies (pancreatic neuroendocrine tumors PNETs). Resection ...is required in selected cases and aims to cure patients and to prevent metastasis. Preoperative imaging is important to assess the number, size, and location of PNETs. However, sensitivity of preoperative imaging modalities to detect small lesions can be rather disappointing. This makes intraoperative reassessment of the pancreas crucial. Methylene blue (MB) accumulates in neuroendocrine lesions after intravenous administration. Methylene blue emits fluorescence of approximately 700 nm and can be visualized using a dedicated near-infrared (NIR) fluorescence imaging system. We present a 58-year-old male patient with multiple endocrine neoplasia type 1 syndrome and 2 lesions suspected as PNETs identified during regular follow-up. Intraoperative administration of MB allowed successful NIR fluorescence imaging of multiple lesions missed by preoperative imaging. After confirmation by intraoperative ultrasound, this new finding led to a major change in treatment: from enucleations to total pancreatectomy. Histopathologic examination confirmed that the fluorescent lesions were indeed neuroendocrine lesions ranging from microadenomas to PNETs. This case demonstrates that intraoperative assessment of neuroendocrine lesions can be improved by intraoperative NIR fluorescence imaging using MB, a safe and relatively easy technique.