In patients with rectal cancer, enlarged lateral lymph nodes (LLNs) result in increased lateral local recurrence (LLR) and lower cancer-specific survival (CSS) rates, which can be improved with ...(chemo)radiotherapy ((C)RT) and LLN dissection (LLND). This study investigated whether different LLN locations affect oncological outcomes.
Patients with low cT3-4 rectal cancer without synchronous distant metastases were included in this multicentre retrospective cohort study. All MRI was re-evaluated, with special attention to LLN involvement and response.
More advanced cT and cN category were associated with the occurrence of enlarged obturator nodes. Multivariable analyses showed that a node in the internal iliac compartment with a short-axis (SA) size of at least 7 mm on baseline MRI and over 4 mm after (C)RT was predictive of LLR, compared with a post-(C)RT SA of 4 mm or less (hazard ratio (HR) 5.74, 95 per cent c.i. 2.98 to 11.05 vs HR 1.40, 0.19 to 10.20; P < 0.001). Obturator LLNs with a SA larger than 6 mm after (C)RT were associated with a higher 5-year distant metastasis rate and lowered CSS in patients who did not undergo LLND. The survival difference was not present after LLND. Multivariable analyses found that only cT category (HR 2.22, 1.07 to 4.64; P = 0.033) and margin involvement (HR 2.95, 1.18 to 7.37; P = 0.021) independently predicted the development of metastatic disease.
Internal iliac LLN enlargement is associated with an increased LLR rate, whereas obturator nodes are associated with more advanced disease with increased distant metastasis and reduced CSS rates. LLND improves local control in persistent internal iliac nodes, and might have a role in controlling systemic spread in persistent obturator nodes.Members of the Lateral Node Study Consortium are co-authors of this study and are listed under the heading Collaborators.
Background
Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence ...guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver.
Methods
Patients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard of care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered 1 day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard.
Results
Twenty-two patients suspected of having hepatocellular carcinoma (
n
= 4), cholangiocarcinoma (
n
= 2) or liver metastases from colorectal carcinoma (
n
= 12), uveal melanoma (
n
= 2), and breast cancer (
n
= 2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80 % (CT), 84 % (MRI), 62 % (inspection), 86 % (LUS), and 92 % (FI), respectively. Three metastases (12 %) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100 % sensitivity).
Conclusion
This study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance.
Purpose
The purpose of this study was to identify suitable molecular targets for tumor-specific imaging of pancreatic adenocarcinoma.
Procedures
The expression of eight potential imaging targets was ...assessed by the target selection criteria (TASC)—score and immunohistochemical analysis in normal pancreatic tissue (
n
= 9), pancreatic (
n
= 137), and periampullary (
n
= 28) adenocarcinoma.
Results
Integrin α
v
β
6
, carcinoembryonic antigen (CEA), epithelial growth factor receptor (EGFR), and urokinase plasminogen activator receptor (uPAR) showed a significantly higher (all
p
< 0.001) expression in pancreatic adenocarcinoma compared to normal pancreatic tissue and were confirmed by the TASC score as promising imaging targets. Furthermore, these biomarkers were expressed in respectively 88 %, 71 %, 69 %, and 67 % of the pancreatic adenocarcinoma patients.
Conclusions
The results of this study show that integrin α
v
β
6
, CEA, EGFR, and uPAR are suitable targets for tumor-specific imaging of pancreatic adenocarcinoma.
Background
Near-infrared (NIR) fluorescence is a promising novel imaging technique that can aid in intraoperative demarcation of pancreatic cancer (PDAC) and thus increase radical resection rates. ...This study investigated SGM-101, a novel, fluorescent-labeled anti-carcinoembryonic antigen (CEA) antibody. The phase 1 study aimed to assess the tolerability and feasibility of intraoperative fluorescence tumor imaging using SGM-101 in patients undergoing a surgical exploration for PDAC.
Methods
At least 48 h before undergoing surgery for PDAC, 12 patients were injected intravenously with 5, 7.5, or 10 mg of SGM-101. Tolerability assessments were performed at regular intervals after dosing. The surgical field was imaged using the Quest NIR imaging system. Concordance between fluorescence and tumor presence on histopathology was studied.
Results
In this study, SGM-101 specifically accumulated in CEA-expressing primary tumors and peritoneal and liver metastases, allowing real-time intraoperative fluorescence imaging. The mean tumor-to-background ratio (TBR) was 1.6 for primary tumors and 1.7 for metastatic lesions. One false-positive lesion was detected (CEA-expressing intraductal papillary mucinous neoplasm). False-negativity was seen twice as a consequence of overlying blood or tissue that blocked the fluorescent signal.
Conclusion
The use of a fluorescent-labeled anti-CEA antibody was safe and feasible for the intraoperative detection of both primary PDAC and metastases. These results warrant further research to determine the impact of this technique on clinical decision making and overall survival.
Up to 38% of pancreatic and periampullary cancer patients undergoing curative intended surgery turn out to have incurable disease. Therefore, staging laparoscopy (SL) prior to laparotomy is advised ...to spare patients the morbidity, inconvenience and expense of futile major surgery. The aim of this study was to assess the added value of SL with laparoscopic ultrasonography (LUS) and laparoscopic near-infrared fluorescence imaging (LFI).
All patients undergoing curative intended surgery of pancreatic or periampullary cancer were included prospectively in this single arm study. Patients received an intravenous infusion of 10 mg indocyanine green (ICG) one or two days prior to surgery to allow LFI. Suspect lesions were analyzed via biopsy or resection. Follow-up visits after surgery occurred every three months.
A total of 25 patients were included. Suspect lesions were identified in 7 patients: liver metastases (n = 2; identified by inspection, LUS, and LFI), peritoneal metastases (n = 1; identified by inspection only), and benign lesions (n = 4; identified by inspection or LUS). Quality of LFI was good in 67% (10/15) of patients dosed one day and 89% (8/9) dosed two days prior to surgery. A futile laparotomy was averted in 3 patients (12%). Following SL the primary tumor was resected in 20 patients. Two patients (10%) developed metastases within 3 months after resection.
Despite current preoperative imaging modalities metastases are still identified during surgery. This study shows limited added value of LUS during SL in patients with pancreatic or periampullary cancer. LFI was of added value due to its high negative predictive value in case of suspect hepatic lesions identified by inspection.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Surgery is the cornerstone of oncologic therapy with curative intent. However, identification of tumor cells in the resection margins is difficult, resulting in nonradical resections, increased ...cancer recurrence and subsequent decreased patient survival. Novel imaging techniques that aid in demarcating tumor margins during surgery are needed. Overexpression of carcinoembryonic antigen (CEA) is found in the majority of gastrointestinal carcinomas, including colorectal and pancreas. We developed ssSM3E/800CW, a novel CEA‐targeted near‐infrared fluorescent (NIRF) tracer, based on a disulfide‐stabilized single‐chain antibody fragment (ssScFv), to visualize colorectal and pancreatic tumors in a clinically translatable setting. The applicability of the tracer was tested for cell and tissue binding characteristics and dosing using immunohistochemistry, flow cytometry, cell‐based plate assays and orthotopic colorectal (HT‐29, well differentiated) and pancreatic (BXPC‐3, poorly differentiated) xenogeneic human–mouse models. NIRF signals were visualized using the clinically compatible FLARE™ imaging system. Calculated clinically relevant doses of ssSM3E/800CW selectively accumulated in colorectal and pancreatic tumors/cells, with highest tumor‐to‐background ratios of 5.1 ± 0.6 at 72 hr postinjection, which proved suitable for intraoperative detection and delineation of tumor boarders and small (residual) tumor nodules in mice, between 8 and 96 hr postinjection. Ex vivo fluorescence imaging and pathologic examination confirmed tumor specificity and the distribution of the tracer. Our results indicate that ssSM3E/800CW shows promise as a diagnostic tool to recognize colorectal and pancreatic cancers for fluorescent‐guided surgery applications. If successfully translated clinically, this tracer could help improve the completeness of surgery and thus survival.
What's new?
The use of fluorescent tracers to identify cancerous cells at tumor margins could improve outcomes for surgery with curative intent. This study describes a newly developed near‐infrared fluorescent tracer targeted to carcinoembryonic antigen (CEA), a glycoprotein overexpressed in gastrointestinal cancers. In mice, the fluorescent agent, ssSM3E/800CW, accumulated specifically in tumor cells, enabling the detection and delineation of tumor borders on a clinically relevant timescale. If successfully translated into the clinic, ssSM3E/800CW could facilitate the visualization of cancerous tissue and improve the completeness of surgical resection.
Background: Fluorescence cholangiography using indocyanine green (ICG) can enhance orientation of bile duct anatomy during laparoscopic cholecystectomy. To ensure clear discrimination between bile ...ducts and liver, the fluorescence ratio between both should be sufficient. This ratio is influenced by the ICG dose and timing of fluorescence imaging. We first systematically identified all strategies for fluorescence cholangiography. Second, we aimed to optimize the dose of ICG and dosing time in a prospective clinical trial. Methods: PubMed was searched for clinical trials studying fluorescence cholangiography. Furthermore, 28 patients planned to undergo laparoscopic cholecystectomy were divided into 7 groups, receiving different intravenous doses (5 or 10 mg ICG) at different time points (0.5, 2, 4, 6, or 24 hours prior to surgery). Results: The systematic review revealed 27 trials including 1057 patients. The majority of studies used 2.5 mg administered within 1 hour before imaging. Imaging 3 to 24 hours after ICG administration was never studied. The clinical trial demonstrated that the highest bile duct-to-liver ratio was achieved 3 to 7 hours after administration of 5 mg and 5 to 25 hours after administration of 10 mg ICG. Up to 3 hours after administration of 5 mg and up to 5 hours after administration of 10 mg ICG, the liver was equally or more fluorescent than the cystic duct, resulting in a ratio ≤1.0. Conclusion: This study shows for the first time that the interval between ICG administration and intraoperative fluorescence cholangiography should be extended. Administering 5 mg ICG at least 3 hours before imaging is easy to implement in everyday clinical practice and results in bile duct-to-liver ratios >1.0.
Abstract Near-infrared (NIR) fluorescence imaging has emerged as a promising complimentary technique for intraoperative visualization of tumor tissue, lymph nodes and vital structures. In this ...review, the current applications and future opportunities of NIR fluorescence imaging in gynecologic oncology are summarized. Several studies indicate that intraoperative sentinel lymph node identification in vulvar cancer using NIR fluorescence imaging outperforms blue dye staining and provides real-time intraoperative imaging of sentinel lymph nodes. NIR fluorescence imaging can penetrate through several millimeters of tissue, revealing structures just below the tissue surface. Hereby, iatrogenic damage to vital structures, such as the ureter or nerves may be avoided by identification using NIR fluorescence imaging. Tumor-targeted probes are currently being developed and have the potential to improve surgical outcomes of cytoreductive and staging procedures, in particular in ovarian cancer. Research in the near future will be necessary to determine whether this technology has additional value in order to facilitate the surgical procedure, reduce morbidity and improve disease-free and overall survival.
Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to ...near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ∼5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.
The aim of this study was to assess the superiority of ICG-99mTc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients ...compared to standard SLN detection using 99mTc-nanocolloid with blue dye.
In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99mTc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications.
Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99mTc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041).
Intraoperative visual detection of SLNs in patients with VSCC using ICG-99mTc-nanocolloid was superior compared to 99mTc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualization.
Clinical Trial Registration: Netherlands Trial Register (Trial ID NL7443).