The OPERA spectrometer is built from two large dipoles instrumented with around 1000 Resistive Plate Chambers (RPCs), covering a surface of about 3350 m super(2), and digitally read out by means of ...almost 27000 strips. The huge number of channels, the inaccessibility of many parts of the detector and the wide uncertainty about the signal amplitude pushed to study a low cost, high sensitivity discriminator, and a very carefully designed layout for the read out system. Here we will present a novel application of LVDS line receiver as discriminator, showing that it exceeds the requirements of a large RPC based detector and offers the intrinsic advantages of a mature technology in terms of costs, reliability and integration scale. We will also present the layout of the read out system showing as the sensitivity and the noise immunity were preserved in a system where the front end electronics is far away from the detector.
Abstract
This papers presents the results of analysis done on a compression-ignition engine supplied with methyl ester of rapeseed oil (Yellow Grease), methyl ester of goose fat (Brown Grease) and ...pure diesel. The analysis included the engine characteristics, emissions and fuel consumption. Results also include chromatographic analysis for all of the three fuels. Additional evaluation was done on a vehicle idling and under load.
A new measurement of inclusive-jet cross sections in the Breit frame in neutral current deep inelastic scattering using the ZEUS detector at the HERA collider is presented. The data were taken in the ...years 2004–2007 at a centre-of-mass energy of
318
GeV
and correspond to an integrated luminosity of
347
pb
-
1
. The jets were reconstructed using the
k
t
-algorithm in the Breit reference frame. They have been measured as a function of the squared momentum transfer,
Q
2
, and the transverse momentum of the jets in the Breit frame,
p
⊥
,
Breit
. The measured jet cross sections are compared to previous measurements and to perturbative QCD predictions. The measurement has been used in a next-to-next-to-leading-order QCD analysis to perform a simultaneous determination of parton distribution functions of the proton and the strong coupling, resulting in a value of
α
s
(
M
Z
2
)
=
0.1142
±
0.0017
(experimental/fit)
-
0.0007
+
0.0006
(model/parameterisation)
-
0.0004
+
0.0006
(scale)
, whose accuracy is improved compared to similar measurements. In addition, the running of the strong coupling is demonstrated using data obtained at different scales.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Objectives
The goal of this work was to conduct a survey of oral health-related quality of life (OHRQoL) among skeletal malocclusion patients who had undergone orthodontic treatment combined with ...orthognathic surgery.
Patients and methods
The study included 28 patients who had undergone orthodontic therapy combined with orthognathic surgery (surgical repositioning osteotomy) to treat skeletal malocclusion. OHRQoL was assessed based on a 14-item German version of the Oral Health Impact Profile (OHIP-G14) and an additional questionnaire developed by the authors to evaluate aspects of quality of life specific to skeletal malocclusion patients.
Results
The mean OHIP-G14 score demonstrates that the malocclusion patients have a lower OHRQoL than the general population. The information collected via our skeletal malocclusion questionnaire correlates with the patients’ perceived esthetic and functional outcomes of treatment as well as their psychological state and social interactions. Satisfaction with treatment outcomes and improved social interactions correlated with high OHRQoL scores. High OHRQoL scores significantly correlated with enhanced well-being and the intensification of social contacts.
Conclusion
Our skeletal malocclusion questionnaire provides useful additional information on specific aspects of skeletal malocclusion patients, mapping in a detailed fashion aspects of function, esthetics, psychological condition, and social interactions. OHIP-G14 scores correlated negatively with OHRQoL.
The exclusive deep inelastic electroproduction of ψ(2S) and J/ψ(1S) at an ep centre-of-mass energy of 317 GeV has been studied with the ZEUS detector at HERA in the kinematic range 2<Q2<80 GeV2, ...30<W<210 GeV and |t|<1 GeV2, where Q2 is the photon virtuality, W is the photon–proton centre-of-mass energy and t is the squared four-momentum transfer at the proton vertex. The data for 2<Q2<5 GeV2 were taken in the HERA I running period and correspond to an integrated luminosity of 114 pb−1. The data for 5<Q2<80 GeV2 are from both HERA I and HERA II periods and correspond to an integrated luminosity of 468 pb−1. The decay modes analysed were μ+μ− and J/ψ(1S)π+π− for the ψ(2S) and μ+μ− for the J/ψ(1S). The cross-section ratio σψ(2S)/σJ/ψ(1S) has been measured as a function of Q2,W and t. The results are compared to predictions of QCD-inspired models of exclusive vector-meson production.
Tests of OPERA RPC detectors Bergnoli, A.; Borsato, E.; Brugnera, R. ...
IEEE transactions on nuclear science,
12/2005, Letnik:
52, Številka:
6
Journal Article
Recenzirano
OPERA is part of the CNGS project and it is an experiment dedicated to the observation of long-baseline nu mu into nu tau oscillations through tau appearance. Resistive Plate Chambers (RPCs) with ...bakelite electrodes are used to instrument the 2 cm gaps between the magnetized iron slabs of the two spectrometers. The RPC installation ended in may 2004 on the first spectrometer and in march 2005 on the second one. Before the installation, every RPC is subjected to a complete test chain in order to reject the poorer quality detectors. The tests are performed in dedicated facilities to ensure the proper RPC gluing, to measure its electrical properties and to verify the response to cosmic rays and the intrinsic noise levels. We have also tested the long term stability of real size OPERA RPC prototypes operated at cosmic ray fluxes for more than one year. On small size prototypes we are performing studies on the gas mixtures in order to reduce the total charge released in the gas for each detector count. The validation of the installed RPCs has been performed with pure nitrogen. A small part of them has been also tested with the gas mixture Ar/C 2 H 2 F 4 /i-C 4 H 10 /SF 6 =75.4/20/4/0.6
Introduction
Multidisciplinary treatment of skeletal malocclusion by orthognathic surgery in addition to orthodontics is a routine strategy believed to offer good functional and esthetic outcomes. ...Postoperative relapse is, however, a problem. The present study was conducted to analyze the stability of outcomes achieved by surgical treatment of skeletal class III patients in terms of the rate and extent of relapses.
Patients and methods
A total of 30 patients who had undergone orthodontic treatment combined with orthognathic surgery were included. The primary inclusion criterion was a skeletal class III treated by mandibular setback (Obwegeser/Dal Pont) surgery alone or combined with maxillary advancement (Le Fort I) surgery. Analysis was based on one preoperative and two postoperative cephalograms per patient.
Results
We observed relapse (defined, in accordance with Proffit, as changes >2 mm or 2°) at a rate of 24% after bimaxillary procedures, compared to a lower rate of 21% after mandibular setback procedures only. The relapse rate was 21% among patients who had undergone upper-jaw surgery versus 27% among those who had undergone lower-jaw surgery, which was statistically significant.
Conclusion
The majority of patients exhibited stable treatment outcomes. Maxillary advancement procedures were found to be less susceptible to relapse—resulting in more stable outcomes—and mandibular setback distances correlated positively with the degree of the relapse. No statistically significant differences were observed between the procedures conducted in both jaws versus in the lower jaw only, or in the extent of upper-jaw repositioning.