Multiple technologies have developed the endovascular approach to MCA aneurysms. We assess the safety and the efficacy of a systematic endovascular approach in nonselected patients with MCA aneurysms ...and determine predictors of treatment outcomes.
We analyzed data collected between January 2007 and January 2012 in a prospective clinical registry. All patients with MCA aneurysms treated by means of the endovascular approach were included. A multivariate analysis was conducted to identify predictors of complications, recanalization, and outcome.
A total of 120 patients with 131 MCA aneurysms were included. Seventy-nine patients (65.8%) were treated electively and 41 (34.2%) in the setting of subarachnoid hemorrhage. Thirty-three of 131 aneurysms (25.2%) were treated with simple coiling, 79 aneurysms (60.3%) with balloon-assisted coiling, and 19 aneurysms (14.5%) with stent-assisted coiling. Complications occurred in 13.7% of patients. Stent-assisted coiling was significantly associated with more complications (P = .002; OR: 4.86; 95% CI, 1.60-14.72). At 1 month after treatment, both the permanent morbidity (mRS ≤2) and mortality rates were 3.3%, without any significant difference according to the endovascular techniques. Mean angiographic follow-up was 16.3 months. The rate of recanalization was 15.6% without a statistical difference, according to the technique. Larger aneurysms were a predictor of recanalization (P = .016; OR: 1.183; 95% CI, 1.02-1.36). Retreatment was performed in 10 of 131 aneurysms (7.6%).
Even though stent-assisted coiling significantly increases the risk of procedural complications, endovascular treatment of MCA aneurysms is safe, effective, and provides durable aneurysm closure in nonselected patients.
Surgical site infections (SSIs) are the second most common healthcare-associated infection. Active SSI surveillance can help inform preventative measures and assess the impact of these measures.
We ...aimed to describe the evolution in trends over 14 years of prospective active SSI surveillance and implementations of SSI prevention measures in a French Teaching Hospital.
We monitored and included in the study all surgical procedures performed from 2003 to 2016 in eight surgical units. The semi-automated surveillance method consisted of weekly collection of SSI declaration forms (pre-filled with patient and procedure administrative data and microbiology laboratory data), filled-in by surgeons and then monitored by the infection control practitioners.
A total of 181,746 procedures were included in our analysis and 3270 SSIs recorded (global SSI rate 1.8%). The SSI rate decreased significantly from 3.0% in 2003 to 1.1% in 2016. This decrease was mainly in superficial SSIs and high infectious risk procedures. Higher SSI rates were observed for procedures associated with the usual risk factors. During this 14-year period, several evolutions in surgical practices occurred that might have contributed to this decrease.
With an overall decrease in SSI rate throughout the surveillance, our results revealed the benefits of an active and comprehensive hospital SSI surveillance programme for understanding the SSI rate trends, analysing local risk factors and assessing the effectiveness of prevention strategies. These findings also highlighted the importance of the collaboration between surgeons and infection control practitioners.
Conventional laparoscopic surgery (LS) is being challenged by the ever-increasing use of robotic surgery (RS) to perform reconstructive procedures. The purpose of this study was to assess the ...acquisition of skills in both techniques and the potential transfer of skills from one technique to the other when restricted spaces are involved. A preclinical randomized crossover study design was implemented. Twelve subjects performed two different reproducible drill procedures: “Thread the Ring” (TR) and “Transfer the Plot” (TP). To assess surgical proficiency in confined workspaces, these exercises were performed with LS and RS technology in a pediatric laparoscopic surgery (PLS) simulator. Each performance was recorded and evaluated by two reviewers using objective structured assessment of technical skills (OSATS). The times to complete the TP and the TR procedure were significantly shorter with RS compared to LS (64 s vs. 319 s;
p
< 0.0001 for both TP and TR). A significant transfer effect of skills between LS and RS was noted for the TP exercise (
p
= 0.006). The percentage improvement was greater overall with LS, meaning a higher number of trials were required to adequately master the procedure. This study demonstrated that RS performed significantly better compared to LS on pediatric simulation devices. A transfer effect was identified from LS to RS exclusively. The learning curves showed that progression was definitely longer with LS. These results, indicate that novice surgeons should be encouraged to persist with learning LS, and they support the use of a pediatric robotic simulation device.
The purpose of this study was to analyze the feasibility and utility of 3D imaging to help lead positioning during a deep brain stimulation (DBS) procedure. A bilateral subthalamic DBS procedure was ...conducted in 2 patients for idiopathic Parkinson's disease. Subthalamic nucleus targeting was based on preoperative stereotactic MRI. We used the Medtronic O-arm to perform 2D-imaging control (frontal and lateral) as well as quick (<30 s) 3D acquisition. This allowed us to check the positioning of micro-macro electrodes and definite electrodes. 3D images were fused with postoperative CT to assess their accuracy, and with preoperative MRI to visualize the anatomical location of the electrodes. 3D imaging is a quick and safe method to ensure perioperative control of lead placement during DBS procedures.
Vestibular neurotomy is a functional surgery for Meniere's disease in the event of medical treatment failure. The aim of the study was to assess the efficacy and complications of vestibular ...neurotomy, and to address the question of postoperative compensation.
All patients included in this retrospective study underwent a vestibular neurotomy at our center between 2009 and 2016. A preoperative evaluation was performed including MRI, audiometry, and videonystagmography. The functional level of disability was evaluated by the Dizziness Handicap Inventory (DHI) score. In all patients suboccipital retrosigmoid approach was performed. All patients underwent early postoperative vestibular rehabilitation. One month and two years after surgery, we assessed the effectiveness of treatment on dizziness, disability and imbalance. At the time of this study (2 to 8 years), DHI and patients’ satisfaction by patient's global impression of change (PGIC) scale were evaluated.
Fifteen patients aged between 42 and 74 years of age were included in our study. Postoperative complications occurred in two patients (meningitis and a wound infection). At one month, all patients had a dramatic clinical improvement with decreased vertigo. Two years after surgery, 85% of the patients were cured and had no dizziness or balance disorder. Only one patient experienced bilateralization and only one had a persistent poor compensation.
Vestibular neurotomy is a very effective treatment in the case of Meniere's disease resistant to medical treatment, with very good functional results and an extremely low failure rate.
There is a growing body of evidence that carmustine wafer implantation during surgery is an effective therapeutic adjunct to the standard combined radio-chemotherapy regimen using temozolomide in ...newly diagnosed and recurrent high-grade glioma patient management with a statistically significant survival benefit demonstrated across several randomized clinical trials, as well as prospective and retrospective studies (grade A recommendation). Compelling clinical data also support the safety of carmustine wafer implantation (grade A recommendation) in these patients and suggest that observed adverse events can be avoided in experienced neurosurgeon hands. Furthermore, carmustine wafer implantation does not seem to impact negatively on the quality of life and the completion of adjuvant oncological treatments (grade C recommendation). Moreover, emerging findings support the potential of high-grade gliomas molecular status, especially the O(6)-Methylguanine-DNA Methyltransferase promoter methylation status, in predicting the efficacy of such a surgical strategy, especially at recurrence (grade B recommendation). Finally, carmustine wafer implantation appears to be cost-effective in high-grade glioma patients when performed by an experienced team and when total or subtotal resection can be achieved. Altogether, these data underline the current need for a new randomized clinical trial to assess the impact of a maximal safe resection with carmustine wafer implantation followed by the standard combined chemoradiation protocol stratified by molecular status in high-grade glioma patients.
Abstract Objective O-arm® now gives us the opportunity not only to perform 2D but also 3D scans during deep brain stimulation (DBS) procedures. We present our experience with the intraoperative use ...of this device. Our objective was to measure the geometrical accuracy of electrode placement during surgical procedures driven under O-arm® control. Methods Fifteen patients underwent STN-DBS. For the first 4 patients, 3D scans were performed at the end of the procedure. We calculated the accuracy of electrode positioning, i.e. the distance between final electrode positioning and the planned trajectory. For the next 11 patients, who underwent both intraoperative and final 3D scan, we also calculated the accuracy of the microelectrode positioning. Results Average stimulation-induced improvement of UPDRS-III score was 52.5 ± 15%. For the first 4 patients, the mean electrode positioning accuracy was 1.46 ± 0.56 mm. For the 11 patients who underwent intraoperative 3D scan, the mean microelectrodes positioning accuracy was 1.59 ± 1.1 mm. Aberrant positioning was detected in two cases, and was analyzed by fusing 3D scan with preoperative MR images. The definite electrodes positioning accuracy was 1.05 ± 0.54 mm. Conclusion Intraoperative 3D scan is feasible, and can help us detect and correct early aberrant trajectories.