Cobalt-chromium alloys (Co-Cr) are widely used in dentistry due to their excellent mechanical properties and corrosion resistance. Since prosthetic materials must be permanently stable in the oral ...cavity, it is very important to determine the release of ions from alloys in the oral cavity. In dentistry today, metals and alloys are mainly joined by laser and tungsten inert gas (TIG) welding. Therefore, in this work, the release of metal ions from six different Co-Cr alloys joined by these two welding methods was quantified to determine the effects of the welding method on an ion release. Static immersion tests, atomic absorption spectrometry and statistical analysis were performed for this purpose. The results showed that laser-welded alloys release a lower amount of metal ions compared to TIG-welded alloys.
Dental technology has developed materials for prosthetics that are very similar to natural teeth and offer a good balance between durability and esthetics; however, some of these materials are not ...very color-stable under the influence of external factors. Therefore, the aim of this study is to determine and compare the color change (∆E00) of different esthetic monolithic monochromatic CAD/CAM materials after they have been thermocycled and treated with staining solutions. The color parameters were determined using a spectrophotometer on a white and black background. Five CAD/CAM materials were used for this study—CAD/CAM nanoceramic (GC Cerasmart270), CAD/CAM lithium disilicate ceramic (IPS e.max CAD), CAD/CAM polymer (Telio CAD), CAD/CAM composite (Tetric CAD) and CAD/CAM polymer-infiltrated ceramic (Vita Enamic). The test specimens produced were divided into groups and were thermocycled in distilled water. They were then stored for four weeks at 37 °C in either distilled water as a control liquid, black tea, instant coffee or red wine. The aim is also to evaluate the color changes as a function of the exposure time of the staining solutions. The results obtained were analyzed statistically. All CAD/CAM materials tend to discolor to varying degrees. Among the factors contributing to discoloration, red wine proved to be the most significant influencing factor. The conclusion from the results is that the color change is influenced by the type of material, the staining solution, the sample thickness, the color background and the aging time.
Lithium disilicate and zirconia are the two most popular materials for aesthetic and dental prosthetic work; however, due to their limitations, a new material is being researched, namely ...zirconia-reinforced lithium disilicate, the surface of which is treated with different procedures to achieve the best possible surface properties. In this study, the surface of zirconia-reinforced lithium disilicate glass-ceramic was treated using different methods (conventional and laser) to determine the effects of the treatment procedures on the surface properties and surface roughness to achieve a higher strength of adhesion from the self-adhesive resin cement to zirconia-reinforced lithium disilicate. The treated surfaces were investigated using profilometry, X-ray diffraction and energy dispersive X-ray fluorescence. The results obtained were statistically evaluated. The results show that the surface roughness is highest for the samples treated with Er:YAG (erbium-doped yttrium aluminium garnet laser) and silanisation. Furthermore, the surface treatment procedures applied did not change the composition of the surface.
Due to their good mechanical and other properties, cobalt-chromium alloys (Co-Cr) are often used in prosthetic therapy. The metal structures of prosthetic works can be damaged and break, and ...depending on the extent of the damage, they can be re-joined. Tungsten inert gas welding (TIG) produces a high-quality weld with a composition very close to that of the base material. Therefore, in this work, six commercially available Co-Cr dental alloys were joined by TIG welding, and their mechanical properties were evaluated to determine the quality of the TIG process as a technology for joining metallic dental materials and the suitability of the Co-Cr alloys used for TIG welding. Microscopic observations were made for this purpose. Microhardness was measured using the Vickers method. The flexural strength was determined on a mechanical testing machine. The dynamic tests were carried out on a universal testing machine. The mechanical properties were determined for welded and non-welded specimens, and the results were statistically evaluated. The results show the correlation between the investigated mechanical properties and the process TIG. Indeed, characteristics of the welds have an effect on the measured properties. Considering all the results obtained, the TIG-welded I-BOND NF and Wisil M alloys showed the cleanest and most uniform weld and, accordingly, satisfactory mechanical properties, highlighting that they withstood the maximum number of cycles under dynamic load.
This study investigated the effect of different curing conditions on the degree of conversion and mechanical properties of contemporary dual-curing resin cements. The material specimens were either ...light-cured directly, light-cured through a 1-mm lithium disilicate glass-ceramic layer, or self-cured. The degree of conversion was measured in 0.1-mm films using Fourier-transform infrared spectroscopy 1 day, 7 days, and 28 days post-cure. Specimens used to study the flexural strength and modulus were prepared according to the ISO 4049 protocol, stored for 28 days post-cure, and subjected to accelerated aging by absolute ethanol immersion. The degree of conversion values ranged between 44.3–77.8%. Flexural strength varied between 11.4–111.1 MPa, while flexural modulus amounted to 0.7–5.5 GPa. The degree of conversion was significantly affected by material type, curing conditions, and post-cure time; however, variations in curing conditions were the least influential factor. A statistically significant effect of curing conditions on the degree of conversion was identified for only one of the five materials tested, whereas the flexural strength and modulus of all tested materials were significantly reduced in the experimental groups that were light-cured through a ceramic layer or self-cured. The effect size analysis showed that mechanical properties were most affected by the material type, while the differences in curing conditions were less influential. A comparison of the degree of conversion and mechanical properties indicated that different curing conditions may lead to significantly different flexural strength and modulus, which are not necessarily accompanied by identifiable variations in the degree of conversion.
In order to improve the hold and function of dentures for the patient, various prostheses made of metal, mostly metal alloys, are used every day in dental practise. Cobalt-chromium alloys are usually ...the first choice because they have very good mechanical properties and satisfactory clinical conditions. Nowadays, laser welding is increasingly used in dental practise due to its numerous advantages over other technologies. In this work, therefore, six commercially available Co-Cr alloys were investigated. Three of them are used for metal-ceramic work, two for denture frameworks and one is suitable for both applications. They were joined by laser welding and subsequently analysed microscopically. Their mechanical properties were determined and statistically evaluated. The microhardness of the laser-welded alloys is in the range of 282–465 MPa in the weld zone and between 283 and 435 MPa in the heat-affected zone. The flexural strength of the laser-welded alloys is lower than the control group, but an alloy for the metal-ceramic work (I-BOND NF) shows very similar value. Furthermore, this alloy, together with two other metal-ceramic alloys, survived a maximum of cycles in dynamic tests. It was found that the laser method can be used for joining Co-Cr alloys while ensuring appropriate parameters that guarantee the quality of the dental work.
Background: The COMT gene polymorphism is associated with neurological and psychiatric disorders and pain perception. The present study investigates the existence of anxiety and pain perception in ...relation to the COMT (catechol-O-methyltransferase) gene polymorphism in labouring women (during “natural” childbirth) with or without inhaled analgesia. Methods: A total of 181 women who chose vaginal birth were enrolled in this study. To present the difference in pain perception, the parturients were divided into one group (n = 90) that chose labour analgesia with inhaled nitrous oxide (50% nitrous oxide and 50% oxygen) and one group (n = 91) without analgesia. The blood samples were taken during the pregnancy as a part of routine pregnancy controls in the hospital. The COMT gene polymorphism was detected with the PCR technique. The pain perception of parturients was self-evaluated two times according to the VAS (Visual Analogue Scale), and anxiety as a personality trait was determined with the STAI-T (State Trait Anxiety Inventory). Pain perception as well as anxiety were compared according to COMT genotypes. Results: In the 181 pregnant women, there were 40 women (22%) of wild homozygotes (GG) of COMT, 95 women (53%) of mutant heterozygotes (GA), and 46 women (25%) of mutant homozygotes (AA). A negative association of pain perception with the GA (mutant heterozygote) polymorphism of the COMT gene versus the wild-type (GG polymorphism) was observed. The GA polymorphism of the COMT gene was associated with 0.46 units lower pain perception compared to the wild type (GG). The anxiety trait score in group AA was lower than in groups GA and GG. The difference reached statistical significance only when comparing AA versus GA (p > 0.042). Analgesic efficacy of nitrous oxide was noticed in 22% of labouring women who reported moderate pain (VAS score 4–7). Conclusions: The COMT gene polymorphism was associated with pain perception and anxiety among parturients. The COMT gene polymorphism GA was associated with negative pain perception among labouring women. Nitrous oxide showed statistical significance in anxiolytic efficacy during labour in women with mild anxiety as a personality trait. Anxiolytic efficacy of nitrous oxide has shown better efficacy in parturients with the COMT gene polymorphism AA.
To analyze the influence of different surface pretreatments of zirconium dioxide reinforced lithium disilicate ceramics on the shear bond strength of self-adhesive resin cement.
Eighty-four zirconium ...reinforced lithium disilicate disc Vita suprinity (Vita Zahnfabrick, Bad Säckingen, Germany) 14x12x2 mm specimens were fabricated according to the manufacturer's recommendations. The specimens were embedded in acrylic resin blocks and randomly divided in seven groups (n=12/each) accorrding to the treatment: Group 1- 10% hydrofluoric acid; Group 2- silane; Group 3- hydrofluoric and silane; Group 4- sandblasting with silane; Group 5- Er: YAG laser+ silane; Group 6- Nd: YAG laser + silane; and the control group, in which the specimens were not treated. Round shape composite discs (Filtek Bulk fill, 3M ESPE, St.Paul, Minnesota, USA) with 3.5 mm diameter, were made for shear bond strength testing, and then cemented to the ceramic sample surface using composite cement (RelyX U200 Automix, 3M ESPE, Neuss, Germany). After cementing the composite disc on the sample, the samples were subjected to shear bond strength test of 10 N with a "stress rate" of 1 MPa / s. To determine the nature of the fracture (adhesive, cohesive or adhesive-cohesive), the broken samples were examined under a stereomicroscope. The ANOVA test and the Tukey test were used to compare the values of the bond strength characteristics between different types of materials. All tests were performed with a significance level of α = 0.05.
There was a significant difference in the shear bond strength of self-adhesive cement to dental lithium-disilicate ceramics reinforced with zirconium dioxide after different preparation protocols (p<0, 05). The treatment of lithium disilicate ceramics reinforced with zirconium dioxide by silanization, sandblasting + silanization, Nd: YAG + silanization resulted in significantly higher bond strength compared to the control group. There was statistically higher bond strength of self-adhesive cement after pretreatment of lithium disilicate ceramics Nd: YAG + silanization compared to Er: YAG + silanization (p <0.05). Adhesive fracture dominated in the control group, sandblasting + silanization group, and in the laser groups, while mixed fracture dominated in other groups.
Under the limitations of this study, the Nd:YAG irradiation with silanization could be used as pretreatment for providing greater shear bond strength of self-adhesive resin cement to zirconium reinforced lithium disilicate.
Apart from the well-known mechanism of bisphosphonates' cellular effect, embryonic development and the specific features of alveolar bone homeostasis have been discussed. The unique ethiopathogenic ...mechanism which relates osteonecrosis of the jaw and bisphosphonates treatment has not been explained. The emphasis lies on the toxicological effects of bisphosphonates on the physiology of the alveolar bone and on the lasting effect of tooth extraction followed by an infection of the extraction wound and consequent progression into deeper layers of osseous tissue. Epithelial infection includes microbiological findings of Actinomyces species. The risk is pronounced in oncological patients treated with bisphosphonates intravenously in relatively large doses and during a longer period of time, especially with highly potent nitrogen-containing bisphosphonates pamidronate and zoledronate. This review of bisphosphonate-related osteonecrosis of the jaw stresses the significance of some other risk factors (corticosteroids, chemotherapy, tumour tissue etc.) of necrosis development--more precisely of osteomyelitis of the jaw if the microbiological component of the diseases has been taken into account, while the role of the bisphosphonates becomes minor. There is no gold standard for the treatment of jaw osteonecrosis; rather, palliative and minimally invasive treatment is applied, without subsequent oral surgical interventions. Since there is a significant risk of jaw osteonecrosis in oncological patients, the level of oral health is an important factor for the indication of intravenous bisphosphonates treatment.
The aim of this study was to evaluate Croatian undergraduate students' knowledge based on what they learned in the recent course, as well as the students' own judgment and opinions about geriatric ...dentistry education concerning temporomandibular disorders (TMDs) of the elderly. The study was carried out by means of a questionnaire administered in the last study year to students of the School of Dental Medicine, University of Zagreb and students of the Department of Dental Medicine at the School of Medicine, University of Rijeka. Th e questionnaire included questions about relevant specific knowledge on TMD, and statements related to their own opinion about geriatric dentistry education received during the study. Regarding students' knowledge related to TMDs, students from Rijeka gave more positive answers (p=0.012). Students from Rijeka gave more positive answers regarding physical therapy for treatment of TMD (p=0.004) and disc displacement and osteoarthritis as the most common disorders of the temporomandibular joint (p=0.031). Students from Zagreb were more unsatisfi ed with the skills in the field of geriatric dentistry (disagreed 57.45%) than students from Rijeka (45.83% had neutral standpoint and 37.50% agreed) (p=0.005). The level of the participants' knowledge pointed to the need of improving undergraduate dental teaching about the specific geriatric education, including knowledge about TMD.