The eye lens annual dose limit for exposed personnel to ionizing radiation has recently been revised by the ICRP-International Commission on Radiological Protection and the proposed new limit has ...been accepted by European legislation through the Council Directive 2013/59/EURATOM 2013. Among medical exposed personnel, the staff performing interventional cardiology are usually affected by relevant doses. For this reason a survey, employing dosemeters characterized in terms of Hp(3), was performed in order to get the order of magnitude of the doses received by the eye lens, at least as a first guess. The survey showed that the annual dose limit can easily be reached if a proper radiation protection approach is not implemented.
Abstract
Neutron capture reaction cross sections on
$$^{74}$$
74
Ge are of importance to determine
$$^{74}$$
74
Ge production during the astrophysical slow neutron capture process. We present new ...resonance data on
$$^{74}$$
74
Ge(
$$n,\gamma $$
n
,
γ
) reactions below 70 keV neutron energy. We calculate Maxwellian averaged cross sections, combining our data below 70 keV with evaluated cross sections at higher neutron energies. Our stellar cross sections are in agreement with a previous activation measurement performed at Forschungszentrum Karlsruhe by Marganiec et al., once their data has been re-normalised to account for an update in the reference cross section used in that experiment.
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and ...other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of ∼4⋅107 neutrons per nominal proton pulse, which is ∼50 times higher than the one of Experimental ARea 1 (EAR1) of ∼8⋅105 neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector’s response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to γ-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.
•The previous detectors to do capture measurements at n_TOF EAR2 show disadvantages.•The sTED has been made with smaller active volumes and optimized photomultipliers.•The detector shows an excellent response to perform capture measurements at n_TOF EAR2.•In a large energy range, the sTED has been validated to do capture measurements.
.
A new high flux experimental area has recently become operational at the n_TOF facility at CERN. This new measuring station, n_TOF-EAR2, is placed at the end of a vertical beam line at a distance ...of approximately 20m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2meV to 100MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the n_TOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with
197
Au foils in the beam.
Neutron capture reaction cross sections on
\documentclass12pt{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
...\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^{74}$$\end{document}
74
Ge are of importance to determine
\documentclass12pt{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^{74}$$\end{document}
74
Ge production during the astrophysical slow neutron capture process. We present new resonance data on
\documentclass12pt{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^{74}$$\end{document}
74
Ge(
\documentclass12pt{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$n,\gamma $$\end{document}
n
,
γ
) reactions below 70 keV neutron energy. We calculate Maxwellian averaged cross sections, combining our data below 70 keV with evaluated cross sections at higher neutron energies. Our stellar cross sections are in agreement with a previous activation measurement performed at Forschungszentrum Karlsruhe by Marganiec et al., once their data has been re-normalised to account for an update in the reference cross section used in that experiment.
Microstructure-sensitive HCF and VHCF simulations Przybyla, Craig P.; Musinski, William D.; Castelluccio, Gustavo M. ...
International journal of fatigue,
12/2013, Letnik:
57
Journal Article, Conference Proceeding
Recenzirano
This paper provides some background and historical review of how microstructure-sensitive finite element simulations can play a role in understanding the effects of stress amplitude, R-ratio, and ...microstructure on fatigue crack formation and early growth at notches, including pores and non-metallic inclusions for Ti alloys and Ni-base superalloys. The simulations employ fatigue indicator parameters (FIPs) computed over finite volumes that relate to processes of fatigue crack formation and early growth at the scale of individual grains. It is argued that both coarse scale (uncracked, mesoscale) and fine scale FIPs (computed in the vicinity of cracks in single grains or crystals) serve as a driving force for crystallographic fatigue crack growth, and correlate directly with the cyclic crack tip displacement (CTD). Furthermore, variability in high cycle fatigue (HCF) and very high cycle fatigue (VHCF) responses is computationally assessed using multiple statistical volume elements and the distribution of FIPs of extreme value character. The concepts of marked correlation functions and weighted probability density functions are reviewed as a means to quantify the role of multiple microstructure attributes that couple to enhance the extreme value FIPs in the HCF regime. An algorithm for estimation of the cumulative probability distribution of cycles for crack formation and growth from notches in HCF and VHCF is also described.