The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a ...medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowing full flexibility on this scale, allowing in principle any information available from the detector to be used for triggering. The design concept, implementation and performances from the first years of running are illustrated.
NA62 RICH performance: measurement and optimization Anzivino, G.; Barbanera, M.; Bizzeti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Letnik:
952
Journal Article
Recenzirano
Odprti dostop
The Ring Imaging Cherenkov detector of the NA62 experiment at CERN SPS was commissioned in 2014, but the optimal performance was achieved in 2016 after the precise mirror alignment with reconstructed ...tracks. The measurement and monitoring of basic performance parameters is discussed: ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring. The performance is measured with 2016 data on the positron sample. Different contributions to the resolutions are calculated.
The Ring Imaging Cherenkov detector is crucial for the identification of charged particles in the NA62 experiment at the CERN SPS. The detector commissioning was completed in 2016 by the precise ...alignment of mirrors using reconstructed tracks. The alignment procedure and measurement of the basic performance are described. Ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring are evaluated for positron tracks. The contribution of the residual mirror misalignment to the performance is calculated.
Abstract
The NA62 experiment at the CERN SPS aims to measure the branching ratio of the very rare kaon decay
K
+
→
π
+
ν
ν
¯
. The Calorimetric Level 0 Trigger identifies clusters in the ...electromagnetic and hadronic calorimeters. Along with the trigger data sent to the L0 Trigger Processor, readout data is collected to be sent to the L1 software trigger. In this work we present the novel implementation of the readout data collection and forwarding system in the multiple layers of the calorimetric trigger structure. We will also present the commissioning of the system and the performance evaluation on current data taking.
Commissioning and performance of the NA62 RICH detector Anzivino, G.; Aisa, D.; Barbanera, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2017, Letnik:
876
Journal Article
Recenzirano
NA62 is the last generation kaon experiment at CERN SPS aiming to study the decay K+→π+νν¯. The goal of the experiment is to measure the decay branching ratio, O(10−10), with 10% precision collecting ...about 100 K+→π+νν¯ events in three years of data taking and assuming a 10% signal acceptance. The weak signal and the huge background make the experiment very challenging. The NA62 detector must be able to reject background events from decay channels with branching ratios up to 10 orders of magnitude higher than the signal one and with similar experimental signature. In order to achieve the designed goal, good Particle Identification (PID), kinematic rejection and precise timing are required. The key element of the PID in NA62 is the Ring Imaging Cherenkov detector (RICH) to identify pions and muons and to measure the particle arrival time. After a pilot run in 2014, installation and commissioning of the detector were completed in 2015, when also the first physics run took place. Results on the detector performance will be presented together with preliminary results from the 2015 and 2016 physics runs.
The Interventional Radiology (IR) is a well established technique in medical domain aiming to obtain a good X-ray image quality while minimizing the radiation dose absorbed by patients and staff ...members. From a radioprotection point of view, these procedures are considered potentially harmful for interventional radiologists and medical staff. Individual monitoring of operators is very important and is performed by assessing effective dose, equivalent dose to the extremities and eye lens, with the use of passive dosimeters (e.g. TLDs) calibrated in terms of personal dose equivalent
H
p
(10),
H
p
(0.07) and
H
p
(3), respectively.
In this work we will present a proposal for an innovative X-ray dosimeter prototype, capable of real-time measurements, packaged in a small form-factor, with wireless communication to be used for individual operators dosimetry during IR procedures. The proposed real-time dosimeter relies on CMOS Active Pixel Sensor, widely used in visible imaging applications. Some preliminary results on the characterization of CMOS active pixel sensors as diffused X-ray detectors during a typical IR session will be presented.
► We present a proposal for an innovative X-ray dosimeter capable of real-time measurements. ► The sensor part is based on CMOS pixel imagers. ► A wireless communication system will be used to monitor in real-time each operator. ► Preliminary results obtained in typical IR conditions will be presented.