Summary Modern management of acute myocardial infarction is built on a clinical evidence base drawn from many studies undertaken over the past three decades. The evolution in clinical practice has ...substantially reduced mortality and morbidity associated with the condition. Key to this success is the effective integration of antithrombotic therapy combined with timely reperfusion, either primary percutaneous coronary intervention or fibrinolysis for ST-elevation myocardial infarction, and invasive investigation and revascularisation for non-ST-elevation myocardial infarction, underpinned by risk stratification and optimised systems of care. After the development of troponin assays for the detection of myonecrosis, the universal definition and classification of myocardial infarction now indicates the underlying pathophysiology. Additionally, an increasing appreciation of the importance of adverse events, such as bleeding, has emerged. Remaining challenges include the effective translation of this evidence to all patients with myocardial infarction, especially to those not well represented in clinical trials who remain at increased risk of adverse events, such as elderly patients and those with renal failure. On a global level, the epidemic of diabetes and obesity in the developed world and the transition from infectious diseases to cardiovascular disease in the developing world will place an increasing demand on health-care infrastructures required to deliver time-dependent and resource-intensive care. This Seminar discusses the underlying pathophysiology, evolving perspectives on diagnosis, risk stratification, and the invasive and pharmacological management of myocardial infarction.
Thromboembolic risk stratification schemes and clinical guidelines for atrial fibrillation (AF) regard risk as independent of classification into paroxysmal (PAF) and non-paroxysmal atrial ...fibrillation (NPAF). The aim of the current study was to conduct a systematic review evaluating the impact of AF type on thromboembolism, bleeding, and mortality.
PubMed was searched through 27 November 2014 for randomized controlled trials, cohort studies, and case series reporting prospectively collected clinical outcomes stratified by AF type. The incidence of thromboembolism, mortality, and bleeding was extracted. Atrial fibrillation clinical outcome data were extracted from 12 studies containing 99 996 patients. The unadjusted risk ratio (RR) for thromboembolism in NPAF vs. PAF was 1.355 (95% CI: 1.169-1.571, P < 0.001). In the study subset off oral anticoagulation, unadjusted RR was 1.689 (95% CI: 1.151-2.480, P = 0.007). The overall multivariable adjusted hazard ratio (HR) for thromboembolism was 1.384 (95% CI: 1.191-1.608, P < 0.001). The overall unadjusted RR for all-cause mortality was 1.462 (95% CI: 1.255-1.703, P < 0.001). Multivariable adjusted HR for all-cause mortality was 1.217 (95% CI: 1.085-1.365, P < 0.001). Rates of bleeding were similar, with unadjusted RR 1.00 (95% CI: 0.919-1.087, P = 0.994) and adjusted HR 1.025 (95% CI: 0.898-1.170, P = 0.715).
Non-paroxysmal atrial fibrillation is associated with a highly significant increase in thromboembolism and death. These data suggest the need for new therapies to prevent AF progression and further studies to explore the integration of AF type into models of thromboembolic risk.
Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode ...radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the EnligHTN(™) multi-electrode system.
We conducted the first-in-human, prospective, multi-centre, non-randomized study in 46 patients (67% male, mean age 60 years, and mean baseline office blood pressure 176/96 mmHg) with drug-resistant hypertension. The primary efficacy objective was change in office blood pressure from baseline to 6 months. Safety measures included all adverse events with a focus on the renal artery and other vascular complications and changes in renal function. Renal artery denervation, using the EnligHTN system significantly reduced the office blood pressure from baseline to 1, 3, and 6 months by -28/10, -27/10 and -26/10 mmHg, respectively (P < 0.0001). No acute renal artery injury or other serious vascular complications occurred. Small, non-clinically relevant, changes in average estimated glomerular filtration rate were reported from baseline (87 ± 19 mL/min/1.73 m2) to 6 months post-procedure (82 ± 20 mL/min/1.73 m2).
Renal sympathetic denervation, using the EnligHTN multi-electrode catheter results in a rapid and significant office blood pressure reduction that was sustained through 6 months. The EnligHTN system delivers a promising therapy for the treatment of drug-resistant hypertension.
Background
Open Abdomen (OA) cases represent a significant surgical and resource challenge. AbClo is a novel non-invasive abdominal fascial closure device that engages lateral components of the ...abdominal wall muscles to support gradual approximation of the fascia and reduce the fascial gap. The study objective was to assess the economic implications of AbClo compared to negative pressure wound therapy (NPWT) alone on OA management.
Methods
We conducted a cost-minimization analysis using a decision tree comparing the use of the AbClo device to NPWT alone among patients with midline laparotomy for trauma or acute abdominal surgery who were ineligible for primary fascial closure. The time horizon was limited to the length of the inpatient hospital stay, and costs were considered from the perspective of the US Medicare payer. Clinical effectiveness data for AbClo was obtained from a randomized clinical trial. Cost data was obtained from the published literature. Probabilistic and deterministic sensitivity analyses were performed. The primary outcome was incremental cost.
Results
The mean cumulative costs per patient were $76 582 for those treated with NPWT alone and $70,582 for those in the group treated with the AbClo device. Compared to NPWT alone, AbClo was associated with lower incremental costs of −$6012 (95% CI −$19 449 to +$1996). The probability that AbClo was cost-savings compared to NPWT alone was 94%.
Conclusions
The use of AbClo is an economically attractive strategy for management of OA in in patients with midline laparotomy for trauma or acute abdominal surgery who were ineligible for primary fascial closure.
BACKGROUND:High-sensitivity troponin assays promise earlier discrimination of myocardial infarction. Yet, the benefits and harms of this improved discriminatory performance when incorporated within ...rapid testing protocols, with respect to subsequent testing and clinical events, has not been evaluated in an in-practice patient-level randomized study. This multicenter study evaluated the noninferiority of a 0/1-hour high-sensitivity cardiac troponin T (hs-cTnT) protocol in comparison with a 0/3-hour masked hs-cTnT protocol in patients with suspected acute coronary syndrome presenting to the emergency department (ED).
METHODS:Patients were randomly assigned to either a 0/1-hour hs-cTnT protocol (reported to the limit of detection <5 ng/L) or masked hs-cTnT reported to ≤29 ng/L evaluated at 0/3-hours (standard arm). The 30-day primary end point was all-cause death and myocardial infarction. Noninferiority was defined as an absolute margin of 0.5% determined by Poisson regression.
RESULTS:In total, 3378 participants with an emergency presentation were randomly assigned between August 2015 and April 2019. Ninety participants were deemed ineligible or withdrew consent. The remaining participants received care guided either by the 0/1-hour hs-cTnT protocol (n=1646) or the 0/3-hour standard masked hs-cTnT protocol (n=1642) and were followed for 30 days. Median age was 59 (49–70) years, and 47% were female. Participants in the 0/1-hour arm were more likely to be discharged from the ED (0/1-hour arm45.1% versus standard arm32.3%, P<0.001) and median ED length of stay was shorter (0/1-hour arm4.6 interquartile range, 3.4–6.4 hours versus standard arm5.6 (interquartile range, 4.0–7.1) hours, P<0.001). Those randomly assigned to the 0/1-hour protocol were less likely to undergo functional cardiac testing (0/1-hour arm7.5% versus standard arm11.0%, P<0.001). The 0/1-hour hs-cTnT protocol was not inferior to standard care (0/1-hour arm17/1646 1.0% versus 16/1642 1.0%; incidence rate ratio, 1.06 0.53–2.11, noninferiority P value=0.006, superiority P value=0.867), although an increase in myocardial injury was observed. Among patients discharged from ED, the 0/1-hour protocol had a negative predictive value of 99.6% (95% CI, 99.0–99.9%) for 30-day death or myocardial infarction.
CONCLUSIONS:This in-practice evaluation of a 0/1-hour hs-cTnT protocol embedded in ED care enabled more rapid discharge of patients with suspected acute coronary syndrome. Improving short-term outcomes among patients with newly recognized troponin T elevation will require an evolution in management strategies for these patients.