•Strategies how to develop AI applications as clinical decision support systems are provided.•We focus on differences between radiomic machine learning and deep learning application domains.•Pros and ...cons, recommendations and references to software tools are provided.
Artificial intelligence (AI) models are playing an increasing role in biomedical research and healthcare services. This review focuses on challenges points to be clarified about how to develop AI applications as clinical decision support systems in the real-world context.
A narrative review has been performed including a critical assessment of articles published between 1989 and 2021 that guided challenging sections.
We first illustrate the architectural characteristics of machine learning (ML)/radiomics and deep learning (DL) approaches. For ML/radiomics, the phases of feature selection and of training, validation, and testing are described. DL models are presented as multi-layered artificial/convolutional neural networks, allowing us to directly process images. The data curation section includes technical steps such as image labelling, image annotation (with segmentation as a crucial step in radiomics), data harmonization (enabling compensation for differences in imaging protocols that typically generate noise in non-AI imaging studies) and federated learning. Thereafter, we dedicate specific sections to: sample size calculation, considering multiple testing in AI approaches; procedures for data augmentation to work with limited and unbalanced datasets; and the interpretability of AI models (the so-called black box issue). Pros and cons for choosing ML versus DL to implement AI applications to medical imaging are finally presented in a synoptic way.
Biomedicine and healthcare systems are one of the most important fields for AI applications and medical imaging is probably the most suitable and promising domain. Clarification of specific challenging points facilitates the development of such systems and their translation to clinical practice.
The radiation dose associated with contrast-enhanced mammography (CEM) has been investigated only by single-center studies. In this retrospective study, we aimed to compare the radiation dose between ...two centers performing CEM within two prospective studies, using the same type of equipment. The CEM mean glandular dose (MGD) was computed for low energy (LE) and high energy (HE) images and their sum was calculated for each view. MGD and related parameters (entrance dose, breast thickness, compression, and density) were compared between the two centers using the Mann−Whitney test. Finally, per-patient MGD was calculated by pooling the two datasets and determining the contribution of LE and HE images. A total of 348 CEM examinations were analyzed (228 from Center 1 and 120 from Center 2). The median total MGD per view was 2.33 mGy (interquartile range 2.19−2.51 mGy) at Center 1 and 2.46 mGy (interquartile range 2.32−2.70 mGy) at Center 2, with a 0.15 mGy median difference (p < 0.001) equal to 6.2%. LE-images contributed between 64% and 77% to the total patient dose in CEM, with the remaining 23−36% being associated with HE images. The mean radiation dose for a two-view bilateral CEM exam was 4.90 mGy, about 30% higher than for digital mammography.
We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was ...performed to extract publication year, country of origin, study design; patients; mammography unit/vendor, radiation dose, low-/high-energy tube voltage; contrast molecule, concentration and dose; injection modality, ARs and acquisition delay; order of views; examination time. Of 120 retrieved articles, 84 were included from 22 countries (September 2003–January 2019), totalling 14012 patients. Design was prospective in 44/84 studies (52%); in 70/84 articles (83%), a General Electric unit with factory-set kVp was used. Per-view average glandular dose, reported in 12/84 studies (14%), ranged 0.43–2.65 mGy. Contrast type/concentration was reported in 79/84 studies (94%), with Iohexol 350 mgI/mL mostly used (25/79, 32%), dose and flow rate in 72/84 (86%), with 1.5 mL/kg dose at 3 mL/s in 62/72 studies (86%). Injection was described in 69/84 articles (82%), automated in 59/69 (85%), manual in 10/69 (15%) and flush in 35/84 (42%), with 10–30 mL dose in 19/35 (54%). An examination time < 10 min was reported in 65/84 studies (77%), 120 s acquisition delay in 65/84 (77%) and order of views in 42/84 (50%) studies, beginning with the craniocaudal view of the non-suspected breast in 7/42 (17%). Thirty ARs were reported by 14/84 (17%) studies (26 mild, 3 moderate, 1 severe non-fatal) with a pooled rate of 0.82% (fixed-effect model). Only half of CESM studies were prospective; factory-set kVp, contrast 1.5 mL/kg at 3 mL/s and 120 s acquisition delay were mostly used; only 1 severe AR was reported. CESM protocol standardisation is advisable.
Modular dual-mobility (MDM) total hip arthroplasty (THA) is designed with a cobalt-chromium liner inserted into a titanium acetabular component. The purpose of this study is to investigate the ...potential risks for fretting corrosion at this junction, by measuring serum metal ions, after MDM acetabular revision.
Thirty-seven patients with well-functioning revision THAs participated in a cross-sectional study at mean 5.1 (2-10) years after surgery. All received a trabecular titanium MDM acetabular component. The serum levels of cobalt and chromium were measured using mass spectrometry.
The mean values of chromium and cobalt were 2.08 μg/L (95% confidence interval 0.9-3.2, range 0.02-11.8) and 1.99 μg/L (95% confidence interval 0.81-3.17, range 0.07-16.05), respectively. Eleven patients (29, 7%) had ion levels above the normal range, with 6 (16.2%) above 5 μg/L and 5 (13.5%) between 1 and 5 μg/L. A significant correlation was found between an elevated serum metal ion level and University of California Los Angeles score (P = .016).
We conclude that serum metal level elevation may occur secondary to metal debris resulting from corrosion of the index MDM THA. This potential risk should be included in the decision-making process when dealing with revision arthroplasty in young and active patients.
Objectives
To investigate the knowledge of radiologists on breast arterial calcifications (BAC) and attitude about BAC reporting, communication to women, and subsequent action.
Methods
An online ...survey was offered to EUSOBI members, with 17 questions focused on demographics, level of experience, clinical setting, awareness of BAC association with cardiovascular risk, mammographic reporting, modality of BAC assessment, and action habits. Descriptive statistics were used.
Results
Among 1084 EUSOBI members, 378 (34.9%) responded to the survey, 361/378 (95.5%) radiologists, 263 females (69.6%), 112 males (29.6%), and 3 (0.8%) who did not specify their gender. Of 378 respondents, 305 (80.7%) declared to be aware of BAC meaning in terms of cardiovascular risk and 234 (61.9%) to routinely include BAC in mammogram reports, when detected. Excluding one inconsistent answer, simple annotation of BAC presence was declared by 151/233 (64.8%), distinction between low versus extensive BAC burden by 59/233 (25.3%), and usage of an ordinal scale by 22/233 (9.5%) and of a cardinal scale by 1/233 (0.4%). Among these 233 radiologists reporting BAC, 106 (45.5%) declared to orally inform the woman and, in case of severe BAC burden, 103 (44.2%) to investigate cardiovascular history, and 92 (39.5%) to refer the woman to a cardiologist.
Conclusion
Among EUSOBI respondents, over 80% declared to be aware of BAC cardiovascular meaning and over 60% to include BAC in the report. Qualitative BAC assessment predominates. About 40% of respondents who report on BAC, in the case of severe BAC burden, investigate cardiovascular history and/or refer the woman to a cardiologist.
Key Points
• Of 1084 EUSOBI members, 378 (35%) participated: 81% of respondents are aware of breast arterial calcification (BAC) cardiovascular meaning and 62% include BAC in the mammogram report
.
• Of those reporting BAC, description of presence was declared by 65%, low versus extensive burden distinction by 25%, usage of an ordinal scale by 10%, and of a cardinal scale by 0.4%; 46% inform the woman and, in case of severe BAC burden, 44% examine cardiovascular history, and 40% refer her to a cardiologist
.
• European breast radiologists may be ready for large-scale studies to ascertain the role of BAC assessment in the comprehensive framework of female cardiovascular disease prevention
.
Introduction
Total hip arthroplasty (THA) performed for femoral neck fractures (FNFs) is becoming a more frequent treatment in the active elderly population. Since there is limited research available ...presenting clinical outcomes after THA using the anterior-based muscle sparing (ABMS) approach, the aim of this study was to compare this surgical approach to the direct lateral (DL) approach in patients treated by THA for FNFs.
Materials and Methods
We retrospectively reviewed the data prospectively collected as a part of our “Hip Fracture Unit” and included 163 patients who underwent THA from January 2016 to January 2019 for acute displaced FNFs.
Results
A total of 132 patients who completed a minimum 2-years follow up (69 in the ABMS group and 63 in DL group) were included. The ABMS group demonstrated significantly shorter time to reach milestone for hospital discharge (1.5 Days vs 2.1 days, P = .018), while no statistically significant differences were detected in peri-operative complications. At 3 months, the timed up and go test, the Harris Hip Score (HHS) and the Oxford ip Score (OHS) were significantly better (P = .024, .032 and .034, respectively) in the ABMS group compared to the DL group. No differences were found in functional outcomes (HHS and OHS) nor in complication rate at 6, 12 and 24 months.
Discussion
This is one of the first studies to analyze functional results of THA performed for FNFs through an ABMS approach. Results are in line with those already present in the Literature.
Conclusion
ABMS approach allows earlier mobilization and better early functional outcomes, compared to DL approach, in patients undergoing THA for acute displaced FNF. No differences are found after 6 months in functional results and complications rate.
Objectives
To evaluate the diagnostic performance of dual-energy computed tomography (DECT) with regard to its post-processing techniques, namely linear blending (LB), iodine maps (IM), and virtual ...monoenergetic (VM) reconstructions, in diagnosing acute pulmonary embolism (PE).
Methods
This meta-analysis was conducted according to PRISMA. A systematic search on MEDLINE and EMBASE was performed in December 2019, looking for articles reporting the diagnostic performance of DECT on a per-patient level. Diagnostic performance meta-analyses were conducted grouping study parts according to DECT post-processing methods. Correlations between radiation or contrast dose and publication year were appraised.
Results
Seventeen studies entered the analysis. Only lobar and segmental acute PE were considered, subsegmental acute PE being excluded from analysis due to data heterogeneity or lack of data. LB alone was assessed in 6 study parts accounting for 348 patients, showing a pooled sensitivity of 0.87 and pooled specificity of 0.93. LB and IM together were assessed in 14 study parts accounting for 1007 patients, with a pooled sensitivity of 0.89 and pooled specificity of 0.90. LB, IM, and VM together were assessed in 2 studies (for a total 144 patients) and showed a pooled sensitivity of 0.90 and pooled specificity of 0.90. The area under the curve for LB alone, and LB together with IM was 0.93 (not available for studies using LB, IM and VM because of paucity of data). Radiation and contrast dose did not decrease with increasing year of publication.
Conclusions
Considering the published performance of single-energy CT in diagnosing acute PE, either dual-energy or single-energy computed tomography can be comparably used for the detection of acute PE.
Key Points
• Dual-energy CT displayed pooled sensitivity and specificity of 0.87 and 0.93 for linear blending alone, 0.89 and 0.90 for linear blending and iodine maps, and 0.90 and 0.90 for linear blending iodine maps, and virtual monoenergetic reconstructions.
• The performance of dual-energy CT for patient management is not superior to that reported in literature for single-energy CT (0.83 sensitivity and 0.96 specificity).
• Dual-energy CT did not yield substantial advantages in the identification of patients with acute pulmonary embolism compared to single-energy techniques.
Total knee arthroplasty (TKA) in patients with post-traumatic extra-articular deformity (EAD) is difficult to manage using conventional instrumentation techniques. In this study, we evaluate whether ...accelerometer navigation system can be a valuable option to make accurate bone resections and restore the neutral mechanical axis in complex TKA patients with EAD.
From May 2015 to June 2017, 18 consecutive TKA were performed in 18 patients with knee osteoarthritis with associated EAD. An accelerometer-based navigation system was used to guide tibial and femoral resection in the coronal and sagittal plane. Postoperative lower limb alignment in coronal plane and component position in coronal and sagittal plane was measured through full-leg weight-bearing X-ray. Clinical score were recorded using the Knee Society Score at the final follow-up.
The mean hip-knee-ankle angle was 0.9° ± 1.4° varus alignment. The coronal alignment of the femoral component was 89.2° ± 1.9°, and the coronal alignment of the tibial component was 89.4° ± 2.1°. The sagittal alignment of the femoral component was 93.2°± 1.9°, and the sagittal alignment of the tibial component was 84.4° ± 3.1°. At the final follow-up, the Knee Society Score was 89 points (range, 82-100), and the functional score was 86.7 points (range, 60-100). No intraoperative and postoperative surgical complications were reported using this technology.
Accelerometer-based navigation is accurate in achieving neutral mechanical alignment and optimal implant position after TKA in patients with EAD. This system should be considered a valuable option to the more complex technique of computer navigation or robotic surgery.
Limited information is available on the brain expression and role of GPR35, a Gi/o coupled receptor activated by kynurenic acid (KYNA). In mouse cultured astrocytes, we detected GPR35 transcript ...using RT-PCR and we found that KYNA (0.1 to 100 µM) decreased forskolin (FRSK)-induced cAMP production (p<0.05). Both CID2745687 (3 µM, CID), a recently described GPR35 antagonist, and GPR35 gene silencing significantly prevented the action of KYNA on FRSK-induced cAMP production. In these cultures, we then evaluated whether GPR35 activation was able to modulate intracellular Ca(2+) concentration (Ca(2+)i ) and Ca(2+)i fluxes. We found that both KYNA and zaprinast, a phosphodiesterase (PDE) inhibitor and GPR35 agonist, did not modify either basal or peaks of Ca(2+)i induced by challenging the cells with ATP (30 µM). However, the Ca(2+)i plateau phase following peak was significantly attenuated by these compounds in a store-operated Ca(2+) channel (SOC)-independent manner. The activation of GPR35 by KYNA and zaprinast was also studied at the CA3-CA1 synapse in the rat hippocampus. Evoked excitatory post synaptic currents (eEPSCs) were recorded from CA1 pyramidal neurons in acute brain slices. The action of KYNA on GPR35 was pharmacologically isolated by using NMDA and α7 nicotinic receptor blockers and resulted in a significant reduction of eEPSC amplitude. This effect was prevented in the presence of CID. Moreover, zaprinast reduced eEPSC amplitude in a PDE5- and cGMP-independent mechanism, thus suggesting that glutamatergic transmission in this area is modulated by GPR35. In conclusion, GPR35 is expressed in cultured astrocytes and its activation modulates cAMP production and Ca(2+)i. GPR35 activation may contribute to KYNA effects on the previously reported decrease of brain extracellular glutamate levels and reduction of excitatory transmission.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK