We performed a meta-meta-analysis to evaluate the prognostic value of coronary flow reserve (CFR) assessed by cardiac positron emission tomography (PET) imaging in patients with suspected or known ...coronary artery disease (CAD).
Studies published until April 2019 were identified by database search. We included studies if they evaluated CFR by PET providing data on adjusted hazard ratio (HR) for the occurrence of adverse events. Annualized event rates were calculated and the incidence rate ratios with 95% confidence interval (CI) were estimated to compare patients with impaired and preserved CFR.
We identified 13 eligible articles including 11,867 patients with a follow-up ranging from 0.6 to 7.1 years. The HR for the occurrence of major adverse cardiac events (MACE) was reported in 11 studies and pooled HR was 1.93 (95% CI 1.65-2.27). The HR for the occurrence of hard events was reported in 5 studies and pooled HR was 3.11 (95% CI 1.88-5.14). Six studies reported data useful to calculate separately the incidence rate of MACE in patients with preserved and impaired CFR and pooled IRR was 2.26 (CI 95% 1.79-2.85). Three studies reported data useful to calculate separately the incidence rate of hard events in patients with preserved and impaired CFR and pooled IRR was 4.12 (CI 95% 3.08-5.51). At meta-regression analysis, we found an association between HR for MACE and gender, diabetes and hypertension, while no significant association was found between HR for hard events and demographic and clinical variables.
In patients with suspected or known CAD, an impaired CFR is associated with adverse cardiovascular events. However, the large heterogeneity in study population underlines the need for further investigations to maximize the prognostic role of CFR.
To evaluate an MRI radiomics-powered machine learning (ML) model's performance for the identification of deep myometrial invasion (DMI) in endometrial cancer (EC) patients and explore its clinical ...applicability.
Preoperative MRI scans of EC patients were retrospectively selected. Three radiologists performed whole-lesion segmentation on T2-weighted images for feature extraction. Feature robustness was tested before randomly splitting the population in training and test sets (80/20% proportion). A multistep feature selection was applied to the first, excluding noninformative, low variance features and redundant, highly-intercorrelated ones. A Random Forest wrapper was used to identify the most informative among the remaining. An ensemble of J48 decision trees was tuned and finalized in the training set using 10-fold cross-validation, and then assessed on the test set. A radiologist evaluated all MRI scans without and with the aid of ML to detect the presence of DMI. McNemars's test was employed to compare the two readings.
Of the 54 patients included, 17 had DMI. In all, 1132 features were extracted. After feature selection, the Random Forest wrapper identified the three most informative which were used for ML training. The classifier reached an accuracy of 86% and 91% and areas under the Receiver Operating Characteristic curve of 0.92 and 0.94 in the cross-validation and final testing, respectively. The radiologist performance increased from 82% to 100% when using ML (p = 0.48).
We proved the feasibility of a radiomics-powered ML model for DMI detection on MR T2-w images that might help radiologists to increase their performance.
Objectives
To build a machine learning (ML) model to detect extraprostatic extension (EPE) of prostate cancer (PCa), based on radiomics features extracted from prostate MRI index lesions.
Methods
...Consecutive MRI exams of patients undergoing radical prostatectomy for PCa were retrospectively collected from three institutions. Axial T2-weighted and apparent diffusion coefficient map images were annotated to obtain index lesion volumes of interest for radiomics feature extraction. Data from one institution was used for training, feature selection (using reproducibility, variance and pairwise correlation analyses, and a correlation-based subset evaluator), and tuning of a support vector machine (SVM) algorithm, with stratified 10-fold cross-validation. The model was tested on the two remaining institutions’ data and compared with a baseline reference and expert radiologist assessment of EPE.
Results
In total, 193 patients were included. From an initial dataset of 2436 features, 2287 were excluded due to either poor stability, low variance, or high collinearity. Among the remaining, 14 features were used to train the ML model, which reached an overall accuracy of 83% in the training set. In the two external test sets, the SVM achieved an accuracy of 79% and 74% respectively, not statistically different from that of the radiologist (81–83%,
p
= 0.39–1) and outperforming the baseline reference (
p
= 0.001–0.02).
Conclusions
A ML model solely based on radiomics features demonstrated high accuracy for EPE detection and good generalizability in a multicenter setting. Paired to qualitative EPE assessment, this approach could aid radiologists in this challenging task.
Key Points
• Predicting the presence of EPE in prostate cancer patients is a challenging task for radiologists.
• A support vector machine algorithm achieved high diagnostic accuracy for EPE detection, with good generalizability when tested on multiple external datasets.
• The performance of the algorithm was not significantly different from that of an experienced radiologist.
To investigate whether a radiomic machine learning (ML) approach employing texture-analysis (TA) features extracted from primary tumor lesions (PTLs) is able to predict tumor grade (TG) and nodal ...status (NS) in patients with oropharyngeal (OP) and oral cavity (OC) squamous-cell carcinoma (SCC).
Contrast-enhanced CT images of 40 patients with OP and OC SCC were post-processed to extract TA features from PTLs. A feature selection method and different ML algorithms were applied to find the most accurate subset of features to predict TG and NS.
For the prediction of TG, the best accuracy (92.9%) was achieved by Naïve Bayes (NB), bagging of NB and K Nearest Neighbor (KNN). For the prediction of NS, J48, NB, bagging of NB and boosting of J48 overcame the accuracy of 90%.
A radiomic ML approach applied to PTLs is able to predict TG and NS in patients with OC and OP SCC.
Background
Feature reproducibility and model validation are two main challenges of radiomics. This study aims to systematically review radiomic feature reproducibility and predictive model validation ...strategies in studies dealing with CT and MRI radiomics of bone and soft-tissue sarcomas. The ultimate goal is to promote achieving a consensus on these aspects in radiomic workflows and facilitate clinical transferability.
Results
Out of 278 identified papers, forty-nine papers published between 2008 and 2020 were included. They dealt with radiomics of bone (
n
= 12) or soft-tissue (
n
= 37) tumors. Eighteen (37%) studies included a feature reproducibility analysis. Inter-/intra-reader segmentation variability was the theme of reproducibility analysis in 16 (33%) investigations, outnumbering the analyses focused on image acquisition or post-processing (
n
= 2, 4%). The intraclass correlation coefficient was the most commonly used statistical method to assess reproducibility, which ranged from 0.6 and 0.9. At least one machine learning validation technique was used for model development in 25 (51%) papers, and K-fold cross-validation was the most commonly employed. A clinical validation of the model was reported in 19 (39%) papers. It was performed using a separate dataset from the primary institution (i.e., internal validation) in 14 (29%) studies and an independent dataset related to different scanners or from another institution (i.e., independent validation) in 5 (10%) studies.
Conclusions
The issues of radiomic feature reproducibility and model validation varied largely among the studies dealing with musculoskeletal sarcomas and should be addressed in future investigations to bring the field of radiomics from a preclinical research area to the clinical stage.
Imaging plays a crucial role in the management of oncologic patients, from the initial diagnosis to staging and treatment response monitoring. Recently, it has been suggested that its importance ...could be further increased by accessing a new layer of previously hidden quantitative data at the pixel level. Using a multi-step process, radiomics extracts potential biomarkers from medical images that could power decision support tools. Despite the growing interest and rising number of research articles being published, radiomics is still far from fulfilling its promise of guiding oncologic imaging toward personalized medicine. This is, at least partly, due to the heterogeneous methodological quality in radiomic research, caused by the complexity of the analysis pipelines. In this review, we aim to disentangle this complexity with a stepwise approach. Specifically, we focus on challenges to face during image preprocessing and segmentation, how to handle imbalanced classes and avoid information leaks, as well as strategies for the proper validation of findings.
•MRI index lesion shape features can differentiate between csPCa and non csPCa.•Surface area to volume ratio is the best predictor of high-grade prostate cancer.•Surface area to volume ratio performs ...better when extracted from the ADC map.
Prostate multiparametric MRI (mpMRI) is the imaging modality of choice for detecting clinically significant prostate cancer (csPCa). Among various parameters, lesion maximum diameter and volume are currently considered of value to increase diagnostic accuracy. Quantitative radiomics allows for the extraction of more advanced shape features. Our aim was to assess which shape features derived from MRI index lesions correlate with csPCa presence.
We retrospectively enrolled 75 consecutive subjects, who underwent mpMRI on a 3 T scanner, divided based on MRI index lesion Gleason Score in a csPCa group (GS > 3 + 4, n = 41) and a non-csPCa one (n = 34). Ten shape features were extracted both from axial T2-weighted and ADC maps images, after lesion tridimensional segmentation. Univariable and multivariable logistic analysis were used to evaluate the relationship between shape features and csPCa. Diagnostic performance was assessed measuring the area under the curve of the receiver operating characteristic (ROC) analysis. Diagnostic accuracy, sensitivity, and specificity were determined using the best cut-off on each ROC. A P value < 0.05 was considered statistically significant.
Univariable analysis demonstrated that almost every shape feature was statistically significant between csPCa e non-csPCa groups. However, multivariable analysis revealed that the parameter defined as surface area to volume ratio (SAVR), especially when extracted from ADC maps is the strongest independent predictor of csPCa among tested shape features.
The radiomic shape feature SAVR, extracted from ADC maps after index lesion segmentation, appears as a promising tool for csPCa detection.
With this review, we aimed to provide a synopsis of recently proposed applications of machine learning (ML) in radiology focusing on prostate magnetic resonance imaging (MRI). After defining the ...difference between ML and classical rule-based algorithms and the distinction among supervised, unsupervised and reinforcement learning, we explain the characteristic of deep learning (DL), a particular new type of ML, including its structure mimicking human neural networks and its ‘black box’ nature. Differences in the pipeline for applying ML and DL to prostate MRI are highlighted. The following potential clinical applications in different settings are outlined, many of them based only on MRI-unenhanced sequences: gland segmentation; assessment of lesion aggressiveness to distinguish between clinically significant and indolent cancers, allowing for active surveillance; cancer detection/diagnosis and localisation (transition
versus
peripheral zone, use of prostate imaging reporting and data system (PI-RADS) version 2), reading reproducibility, differentiation of cancers from prostatitis benign hyperplasia; local staging and pre-treatment assessment (detection of extraprostatic disease extension, planning of radiation therapy); and prediction of biochemical recurrence. Results are promising, but clinical applicability still requires more robust validation across scanner vendors, field strengths and institutions.
The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms ...of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning based on MR images for a non-invasive prediction of Fuhrman grade, specifically differentiation of high- from low-grade tumor and grade assessment. Images acquired on a 3-Tesla scanner (T2-weighted and post-contrast) from 32 patients (20 with low-grade and 12 with high-grade tumor) were annotated to generate volumes of interest enclosing CCRCC lesions. After image resampling, normalization, and filtering, 2438 features were extracted. A two-step feature reduction process was used to between 1 and 7 features depending on the algorithm employed. A J48 decision tree alone and in combination with ensemble learning methods were used. In the differentiation between high- and low-grade tumors, all the ensemble methods achieved an accuracy greater than 90%. On the other end, the best results in terms of accuracy (84.4%) in the assessment of tumor grade were achieved by the random forest. These evidences support the hypothesis that a combined radiomic and machine learning approach based on MR images could represent a feasible tool for the prediction of Fuhrman grade in patients affected by CCRCC.
Photon-counting computed tomography (CT) is a technology that has attracted increasing interest in recent years since, thanks to new-generation detectors, it holds the promise to radically change the ...clinical use of CT imaging. Photon-counting detectors overcome the major limitations of conventional CT detectors by providing very high spatial resolution without electronic noise, providing a higher contrast-to-noise ratio, and optimizing spectral images. Additionally, photon-counting CT can lead to reduced radiation exposure, reconstruction of higher spatial resolution images, reduction of image artifacts, optimization of the use of contrast agents, and create new opportunities for quantitative imaging. The aim of this review is to briefly explain the technical principles of photon-counting CT and, more extensively, the potential clinical applications of this technology.