Background
On average, 21% of women in the USA treated with Breast Conserving Surgery (BCS) undergo a second operation because of close positive margins. Tumor identification with fluorescence ...imaging could improve positive margin rates through demarcating location, size, and invasiveness of tumors. We investigated the technique’s diagnostic accuracy in detecting tumors during BCS using intravenous indocyanine green (ICG) and a custom-built fluorescence camera system.
Methods
In this single-center prospective clinical study, 40 recruited BCS patients were sub-categorized into two cohorts. In the first ‘enhanced permeability and retention’ (EPR) cohort, 0.25 mg/kg ICG was injected ~ 25 min prior to tumor excision, and in the second ‘angiography’ cohort, ~ 5 min prior to tumor excision. Subsequently, an in-house imaging system was used to image the tumor in situ prior to resection, ex vivo following resection, the resection bed, and during grossing in the histopathology laboratory to compare the technique’s diagnostic accuracy between the cohorts.
Results
The two cohorts were matched in patient and tumor characteristics. The majority of patients had invasive ductal carcinoma with concomitant ductal carcinoma in situ. Tumor-to-background ratio (TBR) in the angiography cohort was superior to the EPR cohort (TBR = 3.18 ± 1.74 vs 2.10 ± 0.92 respectively,
p
= 0.023). Tumor detection reached sensitivity and specificity scores of 0.82 and 0.93 for the angiography cohort and 0.66 and 0.90 for the EPR cohort, respectively (
p
= 0.1051 and
p
= 0.9099).
Discussion
ICG administration timing during the angiography phase compared with the EPR phase improved TBR and diagnostic accuracy. Future work will focus on image pattern analysis and adaptation of the camera system to targeting fluorophores specific to breast cancer.
To identify and evaluate the influence of mentoring and simulated training in laparoscopic colorectal surgery (LCS) and define the key components for learning advanced technical skills.
Laparoscopic ...colorectal surgery is a complex procedure, often being self-taught by senior surgeons. Educational issues such as inadequate training facilities or a shortfall of training fellowships may result in a slow uptake of LCS. The effectiveness of mentored and simulated training, however, remains unclear.
We conducted a systematic search, using Ovid databases. Four study categories were identified: mentored versus nonmentored cases, training case selection, simulation, and assessment. We performed a meta-analysis and a mixed model regression on the difference of the main outcome measures (conversion rates, morbidity, and mortality) for mentored trainees and expert surgeons. We also compared conversion rates of mentored and nonmentored. Meta-analysis of risk factors for conversion was performed using published and unpublished data sets requested from various investigators. For studies on simulation, we compared scores of surveys on the perception of different training courses.
Thirty-seven studies were included. Pooled weighted outcomes of mentored cases (n = 751) showed a lower conversion rate (13.3% vs 20.5%, P = 0.0332) compared with nonmentored cases (n = 695). Compared to expert case series (n = 5313), there was no difference in conversion (P = 0.2835), anastomotic leak (P = 0.8342), or mortality (P = 0.5680). A meta-analysis of training case selection data (n = 4444) revealed male sex (P < 0.0001), previous abdominal surgery (P = 0.0200), a BMI greater than 30 (P = 0.0050), an ASA of less than 2 (P < 0.0001), colorectal cancer (P < 0.0001) and intra-abdominal fistula (P < 0.0001), but not older than 64 years (P = 0.4800), to significantly increase conversion risk. Participants on cadaveric courses were highly satisfied with the teaching value yet trainees on an animal course gave less positive feedback. Structured assessment for LCS has been partially implemented.
This review and meta-analysis supports evidence that trainees can obtain similar clinical results like expert surgeons in laparoscopic colorectal surgery if supervised by an experienced trainer. Cadaveric models currently provide the best value for training in a simulated environment. There remains a need for further research into technical skills assessment and the educational value of simulated training.
Policy makers and providers are under increasing pressure to find innovative approaches to achieving better health outcomes as efficiently as possible. Accountable care, which holds providers ...accountable for results rather than specific services, is emerging in many countries to support such care innovations. However, these reforms are challenging and complex to implement, requiring significant policy and delivery changes. Despite global interest, the evidence on how to implement accountable care successfully remains limited. To improve the evidence base and increase the likelihood of success, we applied a comprehensive framework for assessing accountable care implementation to three promising reforms outside the United States. The framework relates accountable care policy reforms to the competencies of health care organizations and their health policy environments to facilitate qualitative comparisons of innovations and factors that influence success. We present emerging lessons to guide future implementation and evaluation of accountable care reforms to improve access to and the quality and affordability of care.
This approach provides the basis of our research program, which aims to expand operative assessment beyond patient factors and the technical skills of the surgeon; to extend assessment of surgical ...skills beyond bench models to the operating theater; to provide a basis for assessing interventions; and to provide a deeper understanding of surgical outcomes.
Research into surgical outcomes has primarily focused on the role of patient pathophysiological risk factors and on the skills of the individual surgeon. However, this approach neglects a wide range of factors that have been found to be of important in achieving safe, high-quality performance in other high-risk environments. The outcome of surgery is also dependent on the quality of care received throughout the patient's stay in hospital and the performance of a considerable number of health professionals, all of whom are influenced by the environment in which they work.
Drawing on the wider literature on safety and quality in healthcare, and recent papers on surgery, this article argues for a much wider assessment of factors that may be relevant to surgical outcome. In particular, we suggest the development of an "operation profile" to capture all the salient features of a surgical operation, including such factors as equipment design and use, communication, team coordination, factors affecting individual performance, and the working environment. Methods of assessing such factors are outlined, and ethical issues and other potential concerns are discussed.
PURPOSE:
METHODS:
RESULTS:A total of 22 studies, with 1,852 females, were included. Infertility rate was 12 percent before restorative proctocolectomy and 26 percent after, among 945 patients in ...seven studies. The incidence of sexual dysfunction was 8 percent preoperatively and 25 percent postoperatively (7 studies, n = 419). Two studies (n = 62) reported no urinary dysfunction in patients undergoing restorative proctocolectomy. There was an increased incidence of cesarean section after restorative proctocolectomy. During the third trimester of pregnancy, there was an increase in stool frequency by 1.15 stools per day compared with before pregnancy frequency (n = 49 95 percent confidence interval, 0.28-2.03 P = 0.01 chi-squared statistic, 0.04 P = 0.84). No significant differences were seen in pouch function after vaginal delivery (n = 456; weighted mean difference, 0.23; 95 percent confidence interval, 0.43-0.88; P = 0.49; chi-squared statistic, 1.29; P = 0.26).
CONCLUSIONS:
OBJECTIVE:To compare surgical safety and efficiency of 2 image guidance modalities, perfect augmented reality (AR) and side-by-side unregistered image guidance (IG), against a no guidance control ...(NG), when performing a simulated laparoscopic cholecystectomy (LC).
BACKGROUND:Image guidance using AR offers the potential to improve understanding of subsurface anatomy, with positive ramifications for surgical safety and efficiency. No intra-abdominal study has demonstrated any advantage for the technology. Perfect AR cannot be provided in the operative setting in a patient; however, it can be generated in the simulated setting.
METHODS:Thirty-six experienced surgeons performed a baseline LC using the LapMentor simulator before randomization to 1 of 3 study armsAR, IG, or NG. Each performed 3 further LC. Safety and efficiency-related simulator metrics, and task workload (SURG-TLX) were collected.
RESULTS:The IG group had a shorter total instrument path length and fewer movements than NG and AR groups. Both IG and NG took a significantly shorter time than AR to complete dissection of Calot triangle. Use of IG and AR resulted in significantly fewer perforations and serious complications than the NG group. IG had significantly fewer perforations and serious complications than the AR group. Compared with IG, AR guidance was found to be significantly more distracting.
CONCLUSION:Side-by-side unregistered image guidance (IG) improved safety and surgical efficiency in a simulated setting when compared with AR or NG. IG provides a more tangible opportunity for integrating image guidance into existing surgical workflow as well as delivering the safety and efficiency benefits desired.
Laparoscopic rectal cancer surgery aims to provide patients with curative resection while minimizing postoperative morbidity and mortality. This study used meta-analytical techniques to compare ...laparoscopic and open surgery as the primary treatment for patients with rectal cancer with regard to short-term and long-term outcomes.
A literature search was performed on all studies between 1993 and 2004 comparing laparoscopic and open surgery for rectal cancer. Subgroup analysis was performed on patients undergoing abdominoperineal excision of the rectum. The following end points were evaluated: operative outcomes, postoperative recovery, and early and late adverse events.
Twenty studies matched the selection criteria and reported on 2071 subjects, of whom 909 (44%) underwent laparoscopic and 1162 (56%) underwent open surgery for rectal cancer. Time to stomal function (weighted mean difference WMD, -1.52; 95% confidence interval 95% CI, -2.20, -1.01), first bowel movement (WMD, -.72; 95% CI, -1.21, -.22), feeding solids (WMD, -.92; 95% CI, -1.35, -.50), and length of hospital stay (WMD, -2.67; 95% CI, -3.81, -1.54) were all significantly reduced after laparoscopic surgery. In patients who underwent abdominoperineal excision of the rectum, wound infection (odds ratio, .15; 95% CI, .03, .73) and requirement for postoperative parenteral analgesia (WMD, -.63; 95% CI, -1.22, -.04) were also significantly reduced. There was no difference between groups in the extent of oncological clearance.
Laparoscopic rectal cancer surgery results in an earlier postoperative recovery and a resected specimen that is oncologically comparable to open surgery. Results from randomized trials reporting long-term outcomes such as cancer recurrence (local and metastatic) and 5-year survival are eagerly awaited.
Abstract Background Very few studies have addressed the transferability of skills from virtual reality (VR) to real life. The aim of this study was to assess the feasibility and effectiveness of ...teaching intracorporeal knot tying (ICKT) by VR simulation only. Methods Twenty novices underwent structured training of basic skills training on the Minimally Invasive Surgical Trainer simulator (Mentice AB, Gothenburg, Sweden) followed by knot tying training on the LapSim simulator (Surgical Science, Gothenburg, Sweden). They were assessed pre- and post-training on a video trainer. Assessment of performance included motion tracking and video-based checklist. Nonparametric statistical analysis was used, and P < .05 was deemed significant. Results All participants completed a correct knot as compared with only 25% before VR training. Time to completion was 66% faster and knot quality 45% better after VR training. Significant reduction in number of movements ( P = .006) and distance traveled ( P < .000) by both hands after VR training. Conclusions Teaching ICKT by VR simulators only is feasible and effective. Furthermore, this study highlights the complementary use of different VR simulators within a structured curriculum.
The aim of this study was to compare laparoscopic versus open live donor nephrectomy using meta-analytical techniques.
Laparoscopic live donor nephrectomy has gained widespread acceptance and is ...increasingly performed. The body of evidence assessing the safety and efficacy of laparoscopic compared with established open techniques is growing; however, very few randomized control trials exist and individual studies often have small patient numbers with varying results. We combined the available raw data to strengthen the current literature in comparing these techniques.
A literature search was performed and comparative studies published between 1997 and 2006 of open versus laparoscopic donor nephrectomy were included. Outcomes evaluated were operative and warm ischemia times, blood loss, donor complications, length of hospital stay, time to return to work, and delayed graft function.
Seventy-three studies matched the selection criteria and included 6594 patients, 3751 (57%) had undergone laparoscopic surgery and 2843 (43%) open nephrectomy. The open nephrectomy group had shorter operative and warm ischemia times by 52 minutes (P < 0.001) and 102 seconds (P < 0.001), respectively. This did not translate into higher delayed graft function or graft loss rates between the 2 groups. Patients in the laparoscopic group had a shorter hospital stay and a faster return to work by 1.58 days (P < 0.001) and 2.38 weeks (P < 0.001), respectively. There was a significantly higher rate of overall donor complications in the open group (P = 0.007), a finding not reproduced in any subsequent sensitivity analyses. When only randomized control trials were considered, there were shorter operative times (P = 0.002) for the open group but nonsignificantly different warm ischemia times. In contrast to the main analysis there were no differences in the overall complication rate, postoperative analgesia, hospital stay, or time taken to return to work.
Laparoscopic nephrectomy in live donor transplantation is a safe alternative to the open technique. Although open nephrectomy may be associated with shorter operative and warm ischemia times, patients undergoing laparoscopic nephrectomy may benefit from a shorter hospital stay and faster return to work without compromising graft function.
Quantifying innovation in surgery Hughes-Hallett, Archie; Mayer, Erik K; Marcus, Hani J ...
Annals of surgery,
08/2014, Letnik:
260, Številka:
2
Journal Article
Recenzirano
Odprti dostop
The objectives of this study were to assess the applicability of patents and publications as metrics of surgical technology and innovation; evaluate the historical relationship between patents and ...publications; develop a methodology that can be used to determine the rate of innovation growth in any given health care technology.
The study of health care innovation represents an emerging academic field, yet it is limited by a lack of valid scientific methods for quantitative analysis. This article explores and cross-validates 2 innovation metrics using surgical technology as an exemplar.
Electronic patenting databases and the MEDLINE database were searched between 1980 and 2010 for "surgeon" OR "surgical" OR "surgery." Resulting patent codes were grouped into technology clusters. Growth curves were plotted for these technology clusters to establish the rate and characteristics of growth.
The initial search retrieved 52,046 patents and 1,801,075 publications. The top performing technology cluster of the last 30 years was minimally invasive surgery. Robotic surgery, surgical staplers, and image guidance were the most emergent technology clusters. When examining the growth curves for these clusters they were found to follow an S-shaped pattern of growth, with the emergent technologies lying on the exponential phases of their respective growth curves. In addition, publication and patent counts were closely correlated in areas of technology expansion.
This article demonstrates the utility of publically available patent and publication data to quantify innovations within surgical technology and proposes a novel methodology for assessing and forecasting areas of technological innovation.