Objective estimation of minimum hearing levels using auditory brainstem responses (ABRs) elicited by single frequency tone-bursts presented monaurally is currently considered the gold standard. ...However, the data acquisition time to estimate thresholds (for both ears across four audiometric frequencies) using this method usually exceeds the sleep time (ranging between 35 and 49 minutes) in infants below 4 months, thus providing incomplete information of hearing status which in turn delays timely clinical intervention. Alternate approaches using faster rate, or tone-burst trains have not been readily accepted due to additional hardware and software requirements. We propose here a novel binaural multifrequency stimulation paradigm wherein several stimuli of different frequencies are presented binaurally in an interleaved manner. The rationale here is that the proposed paradigm will increase acquisition efficiency, significantly reduce test time, and improve accuracy by incorporating an automatic wave V detection algorithm. It is important to note that this paradigm can be easily implemented in most commercial ABR systems currently used by most clinicians.
Using this binaural multifrequency paradigm, ear specific ABRs were recorded in 30 normal-hearing young adults to both tone-bursts, and narrow-band (NB) iChirps at 500, 1000, 2000, and 4000 Hz. Comparison of ABRs elicited by tone-bursts and narrow-band chirps allowed us to determine if NB iChirps elicited a more robust wave V component compared with the tone-bursts. ABR data were characterized by measures of minimum hearing levels; wave V amplitude; and response detectability for two electrode configurations (high forehead-C7; and high forehead-linked mastoids).
Consistent with the research literature, wave V response amplitudes were relatively more robust for NB iChirp stimuli compared with tone-burst stimuli. The easier identification and better detectability of wave V for the NB iChirps at lower stimulus levels contributed to their better thresholds compared with tone-burst elicited responses. It is important to note that binaural multifrequency hearing levels close to minimum hearing levels were determined in approximately 22 minutes using this paradigm-appreciably quicker than the 45 to 60 minutes or longer time required for threshold determination using the conventional single frequency method.
Our novel and simple paradigm using either NB iChirps or tone-bursts provides a reliable method to rapidly estimate the minimum hearing levels across audiometric frequencies for both ears. Incorporation of an automatic wave V detection algorithm increases objectivity and further reduce test time and facilitate early hearing identification and intervention.
We integrated data from a newborn hearing screening database and a preschool disability database to examine the relationship between newborn click evoked auditory brainstem responses (ABRs) and ...developmental disabilities. This sample included children with developmental delay (
n
= 2992), speech impairment (SI,
n
= 905), language impairment (
n
= 566), autism spectrum disorder (ASD,
n
= 370), and comparison children (
n
= 128,181). We compared the phase of the ABR waveform, a measure of sound processing latency, across groups. Children with SI and children with ASD had greater newborn ABR phase values than both the comparison group and the developmental delay group. Newborns later diagnosed with SI or ASD have slower neurological responses to auditory stimuli, suggesting sensory differences at birth.
Sudden infant death syndrome (SIDS)—the sudden and unexplained death of a seemingly healthy infant, <1 year old—may be associated with abnormalities in the brain regions that underlie breathing and ...arousal during sleep. While post‐mortem studies suggest abnormalities in SIDS infants' brainstems, there are no studies of these infants' brainstem function before death. One way to assess the function of the brainstem is with auditory brainstem response (ABR), a routine hearing‐screening method that noninvasively measures the brainstem's response to sound. We hypothesize that anomalies in newborns' ABR measures may predict SIDS. Indeed, previous studies identified abnormalities in ABR characteristics in small samples of near‐miss SIDS infants hospitalized for infant apnea syndrome. However, there is a need to examine the ABRs of infants who died of SIDS. Therefore, in the current study, we propose integrating two secondary datasets to examine newborns' ABRs (N = 156,972), including those who later died of SIDS (n = ~42; .27 out of every 1000 infants), using existing archived records of neonatal ABR results from a sample of newborns born in Florida. We hypothesize that infants who die from SIDS are more likely than non‐SIDS infants to have abnormal ABRs as newborns. Understanding the association between SIDS and ABR may facilitate more accurate identification of an infant's risk for SIDS at birth, enabling increased monitoring, which may facilitate interventions and improve survivorship.
Previous studies report prolonged auditory brainstem response (ABR) in children and adults with autism spectrum disorder (ASD). Despite its promise as a biomarker, it is unclear whether healthy ...newborns who later develop ASD also show ABR abnormalities. In the current study, we extracted ABR data on 139,154 newborns from their Universal Newborn Hearing Screening, including 321 newborns who were later diagnosed with ASD. We found that the ASD newborns had significant prolongations of their ABR phase and V‐negative latency compared with the non‐ASD newborns. Newborns in the ASD group also exhibited greater variance in their latencies compared to previous studies in older ASD samples, likely due in part to the low intensity of the ABR stimulus. These findings suggest that newborns display neurophysiological variation associated with ASD at birth. Future studies with higher‐intensity stimulus ABRs may allow more accurate predictions of ASD risk, which could augment the universal ABR test that currently screens millions of newborns worldwide.
Lay Summary
Children with autism spectrum disorder (ASD) have slow brain responses to sounds. We examined these brain responses from newborns' hearing tests and found that newborns who were later diagnosed with autism also had slower brain responses to sounds. Future studies might use these findings to better predict autism risk, with a hearing test that is already used on millions of newborns worldwide.
The effects of rate on auditory-evoked potentials (AEP) to short noise gaps (12 ms) recorded at high sampling rates using wide-band filters were investigated.
Auditory brainstem (ABR), middle latency ...(MLR), late latency (LLR) and steady-state (ASSR) responses were simultaneously recorded in adult subjects at four gap rates (0.5, 1, 5 and 40 Hz). Major components (V, Na, Pa, Nb, Pb, N1 and P2) were identified at each rate and analysed for latency/amplitude characteristics. Gap responses at 40 Hz were recovered from Quasi-ASSRs (QASSR) using the CLAD deconvolution method.
Fourteen right ears of young normal hearing subjects were tested.
All major components were present in all subjects at 1 Hz. P1 (P50) appeared as a low-pass filtered component of Pa and Pb waves. At higher rates, N1 and P2 disappeared completely while major ABR-MLR components were identified. Peak latencies were mostly determined by noise onsets slightly delayed by offset responses.
Major AEP components can be recorded to short gaps at 1 Hz using high sampling rates and wide-band filters. At higher rates, only ABR and MLRs can be recorded. Such simultaneous recordings may provide a complete assessment of temporal resolution and processing at different levels of auditory pathways.
The middle-ear system relies on a balance of mass and stiffness characteristics for transmitting sound from the external environment to the cochlea and auditory neural pathway. Phase is one aspect of ...sound that, when transmitted and encoded by both ears, contributes to binaural cue sensitivity and spatial hearing. The study aims were (i) to investigate the effects of middle-ear stiffness on the auditory brainstem neural encoding of phase in human adults with normal pure-tone thresholds and (ii) to investigate the relationships between middle-ear stiffness-induced changes in wideband acoustic immittance and neural encoding of phase. The auditory brainstem neural encoding of phase was measured using the auditory steady-state response (ASSR) with and without middle-ear stiffness elicited via contralateral activation of the middle-ear muscle reflex (MEMR). Middle-ear stiffness was quantified using a wideband acoustic immittance assay of acoustic absorbance. Statistical analyses demonstrated decreased ASSR phase lag and decreased acoustic absorbance with contralateral activation of the MEMR, consistent with increased middle-ear stiffness changing the auditory brainstem neural encoding of phase. There were no statistically significant correlations between stiffness-induced changes in wideband acoustic absorbance and ASSR phase. The findings of this study may have important implications for understanding binaural cue sensitivity and horizontal plane sound localization in audiologic and otologic clinical populations that demonstrate changes in middle-ear stiffness, including cochlear implant recipients who use combined electric and binaural acoustic hearing and otosclerosis patients.
Neurodevelopmental disorders are on the rise worldwide, with diagnoses that detect derailment from typical milestones by 3 to 4.5 years of age. By then, the circuitry in the brain has already reached ...some level of maturation that inevitably takes neurodevelopment through a different course. There is a critical need then to develop analytical methods that detect problems much earlier and identify targets for treatment. We integrate data from multiple sources, including neonatal auditory brainstem responses (ABR), clinical criteria detecting autism years later in those neonates, and similar ABR information for young infants and children who also received a diagnosis of autism spectrum disorders, to produce the earliest known digital screening biomarker to flag neurodevelopmental derailment in neonates. This work also defines concrete targets for treatment and offers a new statistical approach to aid in guiding a personalized course of maturation in line with the highly nonlinear, accelerated neurodevelopmental rates of change in early infancy.
Electrocochleography (ECochG) to high repetition rate tone bursts may have advantages over ECochG to clicks with standard slow rates. Tone burst stimuli presented at a high repetition rate may ...enhance summating potential (SP) measurements by reducing neural contributions resulting from neural adaptation to high stimulus repetition rates. To allow for the analysis of the complex ECochG responses to high rates, we deconvolved responses using the Continuous Loop Averaging Deconvolution (CLAD) technique. We examined the effect of high stimulus repetition rate and stimulus duration on SP amplitude measurements made with extratympanic ECochG to tone bursts in 20 adult females with normal hearing. We used 500 and 2,000 Hz tone bursts of various stimulus durations (12, 6, 3 ms) and repetition rates (five rates ranging from 7.1 to 234.38/s). A within-subject repeated measures (rate x duration) analysis of variance was conducted. We found that, for both 500 and 2,000 Hz stimuli, the mean deconvolved SP amplitudes were larger at faster repetition rates (58.59 and 97.66/s) compared to slower repetition rates (7.1 and 19.53/s), and larger at shorter stimulus duration compared longer stimulus duration. Our concluding hypothesis is that large SP amplitude to short duration stimuli may originate primarily from neural excitation, and large SP amplitudes to long duration, fast repetition rate stimuli may originate from hair cell responses. While the hair cell or neural origins of the SP to various stimulus parameters remains to be validated, our results nevertheless provide normative data as a step toward applying the CLAD technique to understanding diseased ears.
Pediatric neuropsychologists and researchers commonly interpret a low score as a cognitive weakness. The purpose of the study was to determine the prevalence of low scores for three ...neuropsychological tests used to evaluate executive function in 4,595 healthy children from Latin-America and Spain. Results showed that low scores are common when multiple neuropsychological outcomes are evaluated in healthy individuals. Clinicians should consider the higher probability of low scores in a given individual when evaluating executive functions using various sets of scores to reduce false-positive diagnoses of cognitive deficits in a child.
Celotno besedilo
Dostopno za:
BFBNIB, DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, UILJ, UKNU, UL, UM, UPUK
Continuous loop averaging deconvolution (CLAD) is a new general mathematical theory and method developed to deconvolve overlapping auditory evoked responses obtained at high stimulation rates. Using ...CLAD, arbitrary stimulus sequences are generated and averaged responses deconvolved. Until now, only a few special stimulus series such as maximum length sequences (MLS) and Legendre sequences (LGS) were capable of performing this task. A CLAD computer algorithm is developed and implemented in an evoked potential averaging system. Computer simulations are used to verify the theory and methodology. Auditory brainstem responses (ABR) and middle latency responses (MLR) are acquired from subjects with normal hearing at high stimulation rates to validate and show the feasibility of the CLAD technique.