Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily ...variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson-Mansouri-Sexl parameter |α|≲1.1×10^{-8}, quantifying a violation of time dilation, thus improving by a factor of around 2 the best known constraint obtained with Ives-Stilwell type experiments, and by 2 orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this Letter will improve by orders of magnitude in the near future.
We report on a new test of the gravitational redshift and thus of local position invariance, an integral part of the Einstein equivalence principle, which is the foundation of general relativity and ...all metric theories of gravitation. We use data spanning 1008 days from two satellites of Galileo, Europe's global satellite navigation system, which were launched in 2014, but accidentally delivered on elliptic rather than circular orbits. The resulting modulation of the gravitational redshift of the onboard atomic clocks allows the redshift determination with high accuracy. Additionally, specific laser ranging campaigns to the two satellites have enabled a good estimation of systematic effects related to orbit uncertainties. Together with a careful conservative modeling and control of other systematic effects we measure the fractional deviation of the gravitational redshift from the prediction by general relativity to be (0.19±2.48)×10^{-5} at 1 sigma, improving the best previous test by a factor 5.6. To our knowledge, this represents the first reported improvement on one of the longest standing results in experimental gravitation, the Gravity Probe A hydrogen maser rocket experiment back in 1976.
Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-level accuracy in ...geoid height. However, so far detailed quantitative estimates of the possible improvement in geoid determination when adding such clock measurements to existing data are lacking. We present a first step in that direction with the aim and hope of triggering further work and efforts in this emerging field of chronometric geodesy and geophysics. We specifically focus on evaluating the contribution of this new kind of direct measurements in determining the geopotential at high spatial resolution (
≈
10 km). We studied two test areas, both located in France and corresponding to a middle (Massif Central) and high (Alps) mountainous terrain. These regions are interesting because the gravitational field strength varies greatly from place to place at high spatial resolution due to the complex topography. Our method consists in first generating a synthetic high-resolution geopotential map, then drawing synthetic measurement data (gravimetry and clock data) from it, and finally reconstructing the geopotential map from that data using least squares collocation. The quality of the reconstructed map is then assessed by comparing it to the original one used to generate the data. We show that adding only a few clock data points (less than 1% of the gravimetry data) reduces the bias significantly and improves the standard deviation by a factor 3. The effect of the data coverage and data quality on the results is investigated, and the trade-off between the measurement noise level and the number of data points is discussed.
The Einstein Equivalence Principle (EEP) is one of the foundations of the theory of General Relativity and several alternative theories of gravitation predict violations of the EEP. Experimental ...constraints on this fundamental principle of nature are therefore of paramount importance. The EEP can be split into three sub-principles: the universality of free fall (UFF), the local Lorentz invariance (LLI) and the local position invariance (LPI). In this paper we propose to use stable clocks in eccentric orbits to perform a test of the gravitational redshift, a consequence of the LPI. The best test to date was performed with the Gravity Probe A (GP-A) experiment in 1976 with an uncertainty of Our proposal considers the opportunity of using Galileo satellites 5 and 6 to improve on the GP-A test uncertainty. We show that considering realistic noise and systematic effects, and thanks to a highly eccentric orbit, it is possible to improve on the GP-A limit to an uncertainty around after one year of integration of Galileo 5 and 6 data.
The Atomic Clocks Ensemble in Space (ACES/PHARAO mission, ESA & CNES) will be installed on board the International Space Station (ISS) next year. A crucial part of this experiment is its two-way ...microwave link (MWL), which will compare the timescale generated on board with those provided by several ground stations disseminated on the Earth. A dedicated data analysis center is being implemented at SYRTE-Observatoire de Paris, where our team currently develops theoretical modelling, numerical simulations and the data analysis software itself. In this paper, we present some key aspects of the MWL measurement method and the associated algorithms for simulations and data analysis. We show the results of tests using simulated data with fully realistic effects such as fundamental measurement noise, Doppler, atmospheric delays, or cycle ambiguities. We demonstrate satisfactory performance of the software with respect to the specifications of the ACES mission. The main scientific product of our analysis is the clock desynchronisation between ground and space clocks, i.e. the difference of proper times between the space clocks and ground clocks at participating institutes. While in flight, this measurement will allow for tests of general relativity and Lorentz invariance at unprecedented levels, e.g. measurement of the gravitational redshift at the 3×10−6 level. As a specific example, we use real ISS orbit data with estimated errors at the 10 m level to study the effect of such errors on the clock desynchronisation obtained from MWL data. We demonstrate that the resulting effects are totally negligible.
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock ...frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation to |δα/α| < 5 × 10−17 for transients of duration 103 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (≳104 km) objects.
We investigate the performance of the upcoming ACES (atomic clock ensemble in space) space mission in terms of its primary scientific objective, the test of the gravitational redshift. Whilst the ...ultimate performance of that test is determined by the systematic uncertainty of the on-board clock at 2-3 ppm, we determine whether, and under which conditions, that limit can be reached in the presence of coloured realistic noise, data gaps and orbit determination (OD) uncertainties. To do so we have developed several methods and software tools to simulate and analyse ACES data. Using those we find that the target uncertainty of 2-3 ppm can be reached after only a few measurement sessions of 10-20 d each, with a relatively modest requirement on OD of 300 m.
Abstract Background and aim Low plasma vitamin D levels have been associated with heart failure (HF). This research attempts to explain the role of vitamin D supplementation on myocardial function in ...elderly patients with HF. Methods and results Twenty-three chronic HF patients were randomized in a small parallel group, double-blind, placebo-controlled trial. All patients, with a mean age of 74 years and vitamin D levels <30 ng/mL, received 800,000 IU (4000 IU/daily) of cholecalciferol or placebo for 6 months. The outcomes measured at baseline and after 6 months were ejection fraction (EF) and other echocardiography parameters, carboxyterminal propeptide of procollagen type I (PIP), natriuretic peptides, lipid profile, renin, parathyroid hormone, blood pressure, and body mass index (BMI). In 13 patients under active treatment for 6 months, mean plasma 25-hydroxy vitamin D concentrations (15.51 vs. −1.40 ng/mL, p < 0.001) and plasma calcium (from 9.3 to 9.6 mmol/L, p < 0.05) increased significantly. However, other biomarkers of bone metabolism did not differ between the treatment and placebo groups. EF increased significantly in the intervention group (6.71 vs. −4.3%; p < 0.001), and the serum concentration of PIP increased only in the placebo group after 6 months (1140.98 vs. −145 mcg/L; p < 0.05). Systolic blood pressure was lower after 6 months of cholecalciferol treatment (from 129.6 to 122.7 mm Hg, p < 0.05). No significant variations were observed for other parameters. Conclusions Six months of vitamin D supplementation significantly improves EF in elderly patients with HF and vitamin D deficiency.
We derive relativistic corrections for one-way and two-way time and frequency transfer over optical fibres neglecting no terms that exceed 1 ps in time and 10−18 in fractional frequency, and estimate ...their magnitude in typical fibre links. We also provide estimates of the uncertainties in the evaluation of the relativistic corrections due to imperfect knowledge of parameters like the coordinates of the fibre and stations, Earth rotation, or thermal effects of the fibre index and length. The links between Teddington(UK) and Paris(F) as well as Braunschweig(D) and Paris(F), that are currently under construction, are studied as specific examples.
Otlertuzumab is a novel humanized anti-CD37 protein therapeutic. This study evaluated the safety of otlertuzumab administered intravenously to patients with chronic lymphocytic leukemia (CLL). ...Otlertuzumab was administered weekly for up to 8 weeks followed by 1 dose per month for 4 months ranging from 0.03 to 20 mg/kg in the dose-escalation phase and 10 to 30 mg/kg in the dose-expansion phase. Responses were determined by using the 1996 National Cancer Institute (NCI-96) and 2008 International Workshop on Chronic Lymphocytic Leukaemia (IWCLL) criteria. Fifty-seven patients were treated in the dose-escalation phase and 26 in the dose-expansion phase. A maximum-tolerated dose was not identified. Response occurred in 19 (23%) of 83 treated patients by NCI-96 criteria. All responses were partial and occurred more commonly in patients with symptomatic untreated CLL (6/7) or 1 to 2 prior therapies (12/28) vs 3 or more therapies (1/48). Twenty percent (12/61) with serial computed tomography scan assessment had a response per IWCLL criteria. The most frequent adverse events were infusion reactions, fatigue, nausea, and diarrhea and were not dose related. Otlertuzumab was well tolerated, and modest clinical activity was observed. Otlertuzumab warrants further evaluation in combination with other agents for the treatment of CLL. This trial was registered at www.clinicaltrials.gov as #NCT00614042.
•Otlertuzumab (formerly TRU-016) has modest single-agent activity in symptomatic treated and untreated CLL.•Otlertuzumab demonstrates an acceptable safety profile, providing rationale for combination with other effective CLL therapies.