The purpose of this study was to evaluate procedural and 1-year clinical and echocardiographic outcomes of patients treated with tricuspid edge-to-edge repair.
Transcatheter edge-to-edge repair has ...been successfully performed in selected patients with symptomatic tricuspid regurgitation (TR) and high risk for surgery, but outcome data are sparse.
This analysis of the multicenter international TriValve (Transcatheter Tricuspid Valve Therapies) registry included 249 patients with severe TR treated with edge-to-edge repair in compassionate and/or off-label use. Clinical and echocardiographic outcomes were prospectively collected and retrospectively analyzed.
In 249 patients (mean age 77 ± 9 years; European System for Cardiac Operative Risk Evaluation II score 6.4% interquartile range: 3.9% to 13.9%), a successful procedure with TR reduction to grade ≤2+ was achieved in 77% by placement of 2 ± 1 tricuspid clips. Concomitant treatment of severe TR and mitral regurgitation was performed in 52% of patients. At 1-year follow-up, significant and durable improvements in TR severity (TR ≤2+ in 72% of patients) and New York Heart Association functional class (≤II in 69% of patients) were observed. All-cause mortality was 20%, and the combined rate of mortality and unplanned hospitalization for heart failure was 35%. Predictors of procedural failure included effective regurgitant orifice area, tricuspid coaptation gap, tricuspid tenting area, and absence of central or anteroseptal TR jet location. Predictors of 1-year mortality were procedural failure, worsening kidney function, and absence of sinus rhythm.
Transcatheter tricuspid edge-to-edge repair can achieve TR reduction at 1 year, resulting in significant clinical improvement. Predictors of procedural failure and 1-year mortality identified here may help select patients who will benefit most from this therapy.
The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure ...device to the incidence of vascular complications is not clear.
To compare the efficacy of a Prostar XL- vs. Perclose ProGlide-based vascular closure strategy.
The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL- (Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics.
Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007).
Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices.
The MitraClip (MC) system is a device for percutaneous, transseptal edge-to-edge reconstruction of the mitral valve (MV) in patients with severe mitral regurgitation (MR) not eligible for surgery. ...Recently, a number of studies have underlined the therapeutic benefit of the MC system for patients with extreme and high risk for MV surgery suffering from either degenerative or functional MR. The MC procedure shows negligible intraprocedural mortality, low periprocedural complication rates, and a significant reduction in MR, as well as an improvement in functional capacity and most importantly quality of life. Presently, the MC system has become an additional interventional tool in the concert of surgical methods. It hereby enlarges the spectrum of MV repair for the Heart Team. Lately, many reviews focused on the MC system. The current review describes the developments in the treatment of MR with the MC system. Keywords: MitraClip, mitral regurgitation, percutaneous mitral valve repair
This study sought to evaluate the impact of the ACURATE neo (NEO) (Boston Scientific, Marlborough, Massachusetts) versus SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) on permanent ...pacemaker implantation (PPI) in patients with pre-existing right bundle branch block (RBBB) after transcatheter aortic valve replacement.
Pre-existing RBBB is the strongest patient-related predictor for PPI after transcatheter aortic valve replacement. No comparison of newer-generation transcatheter heart valves with regard to PPI in these patients exists.
This multicenter registry includes 4,305 patients; 296 (6.9%) had pre-existent RBBB and no pacemaker at baseline and formed the study population. The primary endpoint was new PPI at 30 days. The association of NEO versus S3 with PPI was assessed using binary logistic regression analyses and inverse probability treatment weighting in a propensity-matched population.
The 30-day PPI rate was 39.2%. The S3 and NEO were used in 66.9% and 33.1%, respectively. The NEO was associated with lower rates of PPI compared with the S3 (29.6% vs. 43.9%; p = 0.025; odds ratio OR: 0.54; 95% confidence interval CI: 0.32 to 0.89; p = 0.018), after multivariable adjustment (OR: 0.48; 95% CI: 0.26 to 0.86; p = 0.014), and in the inverse probability treatment weighting analysis (OR: 0.37; 95% CI: 0.25 to 0.55; p < 0.001). There was no difference in device failure (8.2% vs. 6.6%; p = 0.792) or in-hospital course. In the propensity-matched population, PPI rate was also lower in the NEO versus S3 (23.1% vs. 44.6%; p = 0.016; OR: 0.37; 95% CI: 0.17 to 0.78; p = 0.010), with no difference in device failure (9.2% vs. 6.2%; p = 0.742).
In patients with RBBB, risk of PPI was significantly lower with the NEO compared with the S3, suggesting the possibility of a patient tailored transcatheter heart valve therapy.
Display omitted
Abstract Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data ...exist comparing the results of TAVR with new-generation devices versus early-generation devices. Objectives This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices. Methods The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015. Results Of 301 patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT Edwards Lifesciences Corporation, Irvine, California: n = 87; CoreValve Medtronic, Minneapolis, Minnesota: n = 112) and 102 with new-generation devices (Sapien 3 Edwards Lifesciences Corporation: n = 91; Lotus Boston Scientific Corporation, Marlborough, Massachusetts: n = 11). The mean Society of Thoracic Surgeons score was 4.7 ± 5.2 without significant differences between groups (4.6 ± 5.1 vs. 4.9 ± 5.4; p = 0.57). Overall, all-cause mortality rates were 4.3% at 30 days and 14.4% at 1 year. Moderate or severe paravalvular leak was absent and significantly less frequent with new-generation compared to early-generation devices (0.0% vs. 8.5%; p = 0.002), which resulted in a higher device success rate (92.2% vs. 80.9%; p = 0.01). There were no differences between early- and new-generation devices in stroke (2.5% vs. 2.0%; p > 0.99), life-threatening bleeding (3.5% vs. 2.9%; p > 0.99), major vascular complication (4.5% vs. 2.9%; p = 0.76), stage 2 to 3 acute kidney injury (2.5% vs. 2.9%; p > 0.99), early safety endpoints (15.1% vs. 10.8%; p = 0.30), and 30-day all-cause mortality (4.5% vs. 3.9%; p > 0.99). Conclusions The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry Bicuspid TAVR; NCT02394184 )
The study reports for the first time the 30-day outcomes of the first U.S. study with the Cardioband tricuspid valve reconstruction system for the treatment of functional tricuspid regurgitation ...(TR).
Increasing severity of TR is associated with progressively higher morbidity and mortality; however, treatment options for isolated significant disease are limited.
In this single-arm, multicenter, prospective Food and Drug Administration-approved early feasibility study (EFS), 30 patients with severe or greater symptomatic functional TR were enrolled who were deemed candidates for transcatheter tricuspid repair with the Cardioband tricuspid system by the local heart team and multidisciplinary screening committee.
The mean patient age was 77 years, 80% were women, 97% had atrial fibrillation, 70% were in New York Heart Association functional class III to IV with mean left ventricular ejection fraction of 58%, and 27% had severe, 20% massive, and 53% torrential TR. Device success was 93% and all patients were alive at 30 days. Between baseline and 30 days, septolateral tricuspid annular diameter was reduced by 13% (p < 0.001), 85% of patients had ≥1 grade TR reduction and 44% had ≤moderate TR, 75% were in New York Heart Association functional class I to II (p < 0.001), and overall Kansas City Cardiomyopathy Questionnaire score improved by 16 points (p < 0.001).
In patients with severe symptomatic functional TR, this is the first study in the United States with the Cardioband tricuspid system for direct transcatheter annular reduction. This early feasibility study demonstrates high procedural feasibility with no 30-day mortality. There is significant reduction of functional TR with clinically significant improvements in functional status and quality of life. (Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility Study; NCT03382457).
The aim of this study was to retrospectively compare the characteristics, procedural courses, and outcomes of patients presenting with concomitant mitral regurgitation (MR) and tricuspid ...regurgitation (TR) in the TriValve (Transcatheter Tricuspid Valve Therapies) and TRAMI (Transcatheter Mitral Valve Interventions) registries.
Transcatheter mitral edge-to-edge valve repair (TMVR) has been shown to be successful in patients with severe MR. Lately, edge-to-edge repair has also emerged as a possible treatment for severe TR in patients at high risk for cardiac surgery. In patients with both severe MR and TR, the yield of concomitant transcatheter mitral and tricuspid valve repair (TMTVR) for patients at high surgical risk is unknown.
The characteristics, procedural data, and 1-year outcomes of all patients in the international multicenter TriValve registry and the German multicenter TRAMI registry, who presented with both severe MR and TR, were retrospectively compared. Patients in TRAMI (n = 106) underwent isolated TMVR, while those in TriValve (n = 122) additionally underwent concurrent TMTVR in compassionate and/or off-label use.
All 228 patients (mean age 77 ± 8 years, 44.3% women) presented with significant dyspnea at baseline (New York Heart Association functional class III or IV in 93.9%), without any differences in the rates of pulmonary hypertension and chronic pulmonary disease. The proportion of patients with left ventricular ejection fraction <30% was higher in the TMVR group (34.9% vs. 18.0%; p < 0.001), while patients in the TMTVR group had lower glomerular filtration rates. At discharge, MR was comparably reduced in both groups. At 1 year, overall all-cause mortality was 34.0% in the TMVR group and 16.4% in the TMTVR group (p = 0.035, Cox regression). On multivariate analysis, TMTVR was associated with a 2-fold lower mortality rate (hazard ratio: 0.52; p = 0.02). The rate of patients in New York Heart Association functional class ≤II at 1 year did not differ (69.4% vs. 67.0%; p = 0.54).
Concurrent TMTVR was associated with a higher 1-year survival rate compared with isolated TMVR in patients with both MR and TR. Further randomized trials are needed to confirm these results.
Abstract
OBJECTIVES
The aim of the study was to determine the differences in outcomes of surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) in low-risk ...patients.
METHODS
All patients with a logistic EuroSCORE II <4% who underwent transfemoral TAVI between 2008 and 2016 (n = 955) or SAVR between 2009 and 2014 (n = 886) at our centre were included. One hundred and nine patients per group were available for propensity score matching.
RESULTS
Mortality during the 30-day follow-up showed no differences (SAVR vs TAVI: 1.1% vs 1.8%, P = 1.0) but the rates of permanent pacemaker implantation (0.0 vs 14.8%, P < 0.001) and paravalvular leakage ≥ moderate (0.0 vs 7.0%, P = 0.017) were higher in TAVI patients. No difference was found regarding postoperative effective orifice area and transvalvular pressure gradients. Although, the 1-year survival was similar between both groups; 3- and 5-year survival was significantly inferior in the TAVI patient cohort.
CONCLUSIONS
TAVI yielded similar short-term outcomes compared with SAVR despite higher rates of permanent pacemaker implantation and paravalvular leakage ≥ moderate, but inferior long-term survival. Poorer long-term outcomes of the TAVI patient cohort were attributable to a more comorbid TAVI population. This emphasizes the need for long-term results from randomized controlled trials before TAVI can be broadly expanded to younger low-risk patients.
The aim of this study was to assess the clinical outcome of baseline massive or torrential tricuspid regurgitation (TR) after transcatheter tricuspid valve intervention (TTVI).
The use of TTVI to ...treat symptomatic severe TR has been increasing rapidly, but little is known regarding the impact of massive or torrential TR beyond severe TR.
The study population comprised 333 patients with significant symptomatic TR from the TriValve Registry who underwent TTVI. Mid-term outcomes after TTVI were assessed according to the presence of massive or torrential TR, defined as vena contracta width ≥14 mm. Procedural success was defined as patient survival after successful device implantation and delivery system retrieval, with residual TR ≤2+. The primary endpoint comprised survival rate and freedom from rehospitalization for heart failure, survival rate, and rehospitalization at 1 year.
Baseline massive or torrential TR and severe TR were observed in 154 patients (46.2%) and 179 patients (53.8%), respectively. Patients with massive or torrential TR had a higher prevalence of ascites than those with severe TR (27.3% vs. 20.4%, respectively; p = 0.15) and demonstrated a similar procedural success rate (83.2% vs. 77.3%, respectively; p = 0.21). The incidence of peri-procedural adverse events was low, with no significant between-group differences. Freedom from the composite endpoint was significantly lower in patients with massive or torrential TR than in those with severe TR, which was significantly associated with an increased risk for 1-year death of any cause or rehospitalization for heart failure (adjusted hazard ratio: 1.91; 95% confidence interval: 1.10 to 3.34; p = 0.022). Freedom from the composite endpoint was significantly higher in patients with massive or torrential TR when procedural success was achieved (69.9% vs. 54.2%, p = 0.048).
Baseline massive or torrential TR is associated with an increased risk for all-cause mortality and rehospitalization for heart failure 1 year after TTVI. Procedural success is related to better outcomes, even in the presence of baseline massive or torrential TR. (International Multisite Transcatheter Tricuspid Valve Therapies Registry TriValve; NCT03416166)
Display omitted