A precision mass investigation of the neutron-rich titanium isotopes ^{51-55}Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the ...N=32 shell closure, and the overall uncertainties of the ^{52-55}Ti mass values were significantly reduced. Our results conclusively establish the existence of the weak shell effect at N=32, narrowing down the abrupt onset of this shell closure. Our data were compared with state-of-the-art ab initio shell model calculations which, despite very successfully describing where the N=32 shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned multiple-reflection time-of-flight mass spectrometer, substantiated by independent measurements from TITAN's Penning trap mass spectrometer.
The multinucleon transfer (MNT) reaction approach was successfully employed for the first time to measure the isomeric ratios (IRs) of 211Po isomer (25/2+) and its ground state (9/2+) at the IGISOL ...facility using a 945 MeV 136Xe beam impinged on 209Bi and natPb targets. The dominant production of isomers compared to the corresponding ground states was consistently revealed in the α-decay spectra. Deduced IR of 211Po populated through the 136Xe+natPb reaction was found to have an enhancement of ≈1.8-times than that observed for the 136Xe+209Bi. State-of-the-art Langevin-type model calculations have been utilized to estimate the spin distribution of an MNT residue. The computations qualitatively corroborate with the considerable increase in the IRs of 211Po produced from 136Xe+natPb compared to 136Xe+209Bi. Theoretical investigations indicate a weak dependence of target spin on the IRs. The enhancement of the 211Po isomer in the 136Xe+natPb over 136Xe+209Bi can be attributed to the different proton (p)-transfer production routes. Estimations demonstrate an increment in the angular momentum transfer, favorable for isomer production, with increasing projectile energy. Comparative analysis reveals the two entrance channel parameters, projectile mass and p-transfer channels, strongly influencing the population of the high-spin isomer of 211Po (25/2+). This letter reports the first experimental and theoretical study on the IRs of nuclei formed from two different p-transfer channels via two independent MNT reactions.
Abstract
A fast and reliable range monitoring method is required to take full advantage of the high linear energy transfer provided by therapeutic ion beams like carbon and oxygen while minimizing ...damage to healthy tissue due to range uncertainties. Quasi-real-time range monitoring using in-beam positron emission tomography (PET) with therapeutic beams of positron-emitters of carbon and oxygen is a promising approach. The number of implanted ions and the time required for an unambiguous range verification are decisive factors for choosing a candidate isotope. An experimental study was performed at the FRS fragment-separator of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany, to investigate the evolution of positron annihilation activity profiles during the implantation of
$$^{14}$$
14
O and
$$^{15}$$
15
O ion beams in a PMMA phantom. The positron activity profile was imaged by a dual-panel version of a Siemens Biograph mCT PET scanner. Results from a similar experiment using ion beams of carbon positron-emitters
$$^{11}$$
11
C and
$$^{10}$$
10
C performed at the same experimental setup were used for comparison. Owing to their shorter half-lives, the number of implanted ions required for a precise positron annihilation activity peak determination is lower for
$$^{10}$$
10
C compared to
$$^{11}$$
11
C and likewise for
$$^{14}$$
14
O compared to
$$^{15}$$
15
O, but their lower production cross-sections make it difficult to produce them at therapeutically relevant intensities. With a similar production cross-section and a 10 times shorter half-life than
$$^{11}$$
11
C,
$$^{15}$$
15
O provides a faster conclusive positron annihilation activity peak position determination for a lower number of implanted ions compared to
$$^{11}$$
11
C. A figure of merit formulation was developed for the quantitative comparison of therapy-relevant positron-emitting beams in the context of quasi-real-time beam monitoring. In conclusion, this study demonstrates that among the positron emitters of carbon and oxygen,
$$^{15}$$
15
O is the most feasible candidate for quasi-real-time range monitoring by in-beam PET that can be produced at therapeutically relevant intensities. Additionally, this study demonstrated that the in-flight production and separation method can produce beams of therapeutic quality, in terms of purity, energy, and energy spread.
Display omitted
•A new versatile probability distribution function called “hyper-EMG” is presented.•Modeling of asymmetric MR-TOF mass spectra using the hyper-EMG is demonstrated.•Peak shape is ...precisely modeled over 5 orders of magnitude in abundance.•Hyper-EMG outperforms the common peak shape models in case of overlapping peaks.•Improved mass and abundance values are obtained for overlapping peaks in MR-TOF-MS.
A new probability distribution function (PDF) called hyper-Exponentially Modified Gaussian (hyper-EMG) is introduced for the analysis of high-resolution spectra from multiple-reflection time-of-flight mass spectrometers. The hyper-EMG consists of a central Gaussian distribution modified by multiple exponential tails with different strengths at one or both sides. The basic statistical properties of the new PDF are given and the analysis of mass spectra containing separated and overlapping peaks is presented. The main requirement is to accurately determine the positions and areas of the individual mass peaks. From the distances of positions the mass values can be determined, from the areas the population of different ground and isomeric states can be obtained. The hyper-EMG has been applied to high-resolution time and mass spectra characterized by mass resolving powers of 140,000 and 520,000 obtained with Cs+133 and K+39 ions, respectively. From the measured mass distribution of K+39 ions, an overlapping distribution of two peaks with an area ratio of 1:10 and a mass difference of 2.6ppm (parts-per-million) is generated and analyzed. The results reveal significant advantages of the new PDF for the evaluation of overlapping distributions for accurate mass and area determinations compared with commonly used PDFs which are more than one order of magnitude less accurate. It is obvious that the hyper-EMG can be favorably applied also to other fields.
Novel device to study double-alpha decay at the FRS Ion Catcher Varga, L.; Wilsenach, H.; Hall, O. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2024, Letnik:
1063
Journal Article
Recenzirano
Odprti dostop
A novel system has been developed to detect simultaneous double-alpha emission from purified and weightless sources. The system includes the collection of 224Ra low-energy recoils in purified helium ...buffer gas from the decay of 228Th. The recoil products are thermalized and collected in a cryogenic buffer gas cell and extracted into an RF-ion guide for mass selection. The mass-separated ions are implanted at low kinetic energy into a thin carbon foil placed between two large-area double-sided silicon strip detectors to observe correlated alpha-particle emission. The apparatus is described in detail, including insights into its experimental performance.
We have measured for the first time simultaneously both the mean charge states and stopping powers of (35-280) MeV/u 208Pb ions in gases and solids with an accuracy of 1%. The existence at lower ...energies and disappearance at higher of density effects in the charge-state distribution and the corresponding stopping power are directly confirmed and comparisons with widely used theories and simulations for heavy ions demonstrate strong deviations of up to 27%. However, an unprecedented prediction power of better than 3% has been achieved for the energy loss when the measured mean charge-states are implemented in the Lindhard-Sørensen theory. Our present benchmark data contribute to an improved understanding of the basic atomic collision processes and to numerous applications in nuclear physics. Extending the GANIL data 1 to higher accuracy and energies, we can now answer at which velocities the Bohr-Lindhard density effect in stopping will vanish.
Abstract An exploratory program to establish the multi-nucleon transfer (MNT) reaction as a new research direction at the FRS Ion Catcher (FRS-IC) has started at GSI. Its long term goal is the use of ...secondary exotic beams from the Super-FRS to drive MNT reactions. The near term goal is to perform proof-of-principle cross section and mass measurements with slowed-down 238 U beams on targets inside the FRS-IC gas cell. The experimental efficiencies and expected rates are estimated using production cross sections from the Langevin MNT model followed by simulations of the full setup. The impact of the space charge effect inside the gas cell is evaluated in detail.
Reduced transition probabilities have been extracted between excited, yrast states in the N=Z+2 nucleus 94Pd. The transitions of interest were observed following decays of the Iπ=14+, Ex=2129-keV ...isomeric state, which was populated following the projectile fragmentation of a 124Xe primary beam at the GSI Helmholtzzentrum für Schwerionenforschung accelerator facility as part of FAIR Phase-0. Experimental information regarding the reduced E2 transition strengths for the decays of the yrast 8+ and 6+ states was determined following isomer-delayed Eγ1−Eγ2−△T2,1 coincidence method, using the LaBr3(Ce)-based FATIMA fast-timing coincidence gamma-ray array, which allowed direct determination of lifetimes of states in 94Pd using the Generalized Centroid Difference (GCD) method. The experimental value for the half-life of the yrast 8+ state of 755(106) ps results in a reduced transition probability of B(E2:8→+6+) = 205−25+34 e2fm4, which enables a precise verification of shell-model calculations for this unique system, lying directly between the N=Z line and the N=50 neutron shell closure. The determined B(E2) value provides an insight into the purity of (g9/2)n configurations in competition with admixtures from excitations between the (lower) N=3pf and (higher) N=4gds orbitals for the first time. The results indicate weak collectivity expected for near-zero quadrupole deformation and an increasing importance of the T=0 proton-neutron interaction at N=48.
Nuclear mass measurements of isotopes are key to improving our understanding of nuclear structure across the chart of nuclides, in particular, for the determination of the appearance or disappearance ...of nuclear shell closures. We present high-precision mass measurements of neutron-rich Ca, Ti, and V isotopes performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) and the Low Energy Beam and Ion Trap (LEBIT) facilities. These measurements were made using the TITAN multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS) and the LEBIT 9.4T Penning trap mass spectrometer. In total, 13 masses were measured, 8 of which represent increases in precision over previous measurements. These measurements refine trends in the mass surface around N=32 and N=34, and support the disappearance of the N=32 shell closure with increasing proton number. Additionally, our data do not support the presence of a shell closure at N=34.
The FRagment Separator FRS at GSI is a versatile spectrometer and separator for experiments with relativistic in-flight separated short-lived exotic beams. One branch of the FRS is connected to the ...target hall where the bio-medical cave (Cave M) is located. Recently a joint activity between the experimental groups of the FRS and the biophysics at the GSI and Department of physics at LMU was started to perform biomedical experiments relevant for hadron therapy with positron emitting carbon and oxygen beams. This paper presents the new ion-optical mode and commissioning results of the FRS-Cave M branch where positron emitting 15O-ions were provided to the medical cave for the first time. An overall conversion efficiency of 2.9±0.2×10−415O fragments per primary 16O ion accelerated in the synchrotron SIS18 was reached.