The vast majority of proteomic studies to date have relied on mass spectrometric techniques to identify, and in some cases quantify, peptides that have been generated by proteolysis. Current ...approaches differ in the types of instrument used, their performance profiles, the manner in which they interface with biological research strategies, and their reliance on and use of prior information. Here, we consider the three main mass spectrometry (MS)-based proteomic approaches used today: shotgun (or discovery), directed and targeted strategies. We discuss the principles of each technique, their strengths and weaknesses and the dependence of their performance profiles on the composition of the biological sample. Our goal is to provide a rational framework for selecting strategies optimally suited to address the specific research issue under consideration.
Celotno besedilo
Dostopno za:
DOBA, IJS, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Targeted mass spectrometry‐based approaches are nowadays widely used for quantitative proteomics studies and more recently have been implemented on high resolution/accurate mass (HRAM) instruments ...resulting in a considerable performance improvement. More specifically, the parallel reaction monitoring technique (PRM) performed on quadrupole‐Orbitrap mass spectrometers, leveraging the high resolution and trapping capabilities of the instrument, offers a clear advantage over the conventional selected reaction monitoring (SRM) measurements executed on triple quadrupole instruments. Analyses performed in HRAM mode allow for an improved discrimination between signals derived from analytes and those resulting from matrix interferences translating in the reliable quantification of low abundance components. The purpose of the study defines various implementation schemes of PRM, namely: (i) exploratory experiments assessing the detectability of very large sets of peptides (100–1000), (ii) wide‐screen analyses using (crude) internal standards to obtain statistically meaningful (relative) quantitative analyses, and (iii) precise/accurate quantification of a limited number of analytes using calibrated internal standards. Each of the three implementation schemes requires specific acquisition methods with defined parameters to appropriately control the acquisition during the actual peptide elution. This tutorial describes the different PRM approaches and discusses their benefits and limitations in terms of quantification performance and confidence in analyte identification.
Mass Spectrometry and Protein Analysis Domon, Bruno; Aebersold, Ruedi
Science (American Association for the Advancement of Science),
04/2006, Letnik:
312, Številka:
5771
Journal Article
Recenzirano
Mass spectrometry is a central analytical technique for protein research and for the study of biomolecules in general. Driven by the need to identify, characterize, and quantify proteins at ever ...increasing sensitivity and in ever more complex samples, a wide range of new mass spectrometry-based analytical platforms and experimental strategies have emerged. Here we review recent advances in mass spectrometry instrumentation in the context of current and emerging research strategies in protein science.
Targeted high-resolution and accurate mass analyses performed on fast sequencing mass spectrometers have opened new avenues for quantitative proteomics. More specifically, parallel reaction ...monitoring (PRM) implemented on quadrupole-orbitrap instruments exhibits exquisite selectivity to discriminate interferences from analytes. Furthermore, the instrument trapping capability enhances the sensitivity of the measurements. The PRM technique, applied to the analysis of limited peptide sets (typically 50 peptides or less) in a complex matrix, resulted in an improved detection and quantification performance as compared with the reference method of selected reaction monitoring performed on triple quadrupole instruments. However, the implementation of PRM for the analysis of large peptide numbers requires the adjustment of mass spectrometry acquisition parameters, which affects dramatically the quality of the generated data, and thus the overall output of an experiment. A newly designed data acquisition scheme enabled the analysis of moderate-to-large peptide numbers while retaining a high performance level. This new method, called internal standard triggered-parallel reaction monitoring (IS-PRM), relies on added internal standards and the on-the-fly adjustment of acquisition parameters to drive in real-time measurement of endogenous peptides. The acquisition time management was designed to maximize the effective time devoted to measure the analytes in a time-scheduled targeted experiment. The data acquisition scheme alternates between two PRM modes: a fast low-resolution “watch mode” and a “quantitative mode” using optimized parameters ensuring data quality. The IS-PRM method exhibited a highly effective use of the instrument time. Applied to the analysis of large peptide sets (up to 600) in complex samples, the method showed an unprecedented combination of scale and analytical performance, with limits of quantification in the low amol range. The successful analysis of various types of biological samples augurs a broad applicability of the method, which is likely to benefit a wide range of proteomics experiments.
Systems biology relies on data sets in which the same group of proteins is consistently identified and precisely quantified across multiple samples, a requirement that is only partially achieved by ...current proteomics approaches. Selected reaction monitoring (SRM)—also called multiple reaction monitoring—is emerging as a technology that ideally complements the discovery capabilities of shotgun strategies by its unique potential for reliable quantification of analytes of low abundance in complex mixtures. In an SRM experiment, a predefined precursor ion and one of its fragments are selected by the two mass filters of a triple quadrupole instrument and monitored over time for precise quantification. A series of transitions (precursor/fragment ion pairs) in combination with the retention time of the targeted peptide can constitute a definitive assay. Typically, a large number of peptides are quantified during a single LC‐MS experiment. This tutorial explains the application of SRM for quantitative proteomics, including the selection of proteotypic peptides and the optimization and validation of transitions. Furthermore, normalization and various factors affecting sensitivity and accuracy are discussed.
There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has ...been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies.
The recent development of hybrid mass spectrometers with high resolution and accurate mass capabilities has opened new avenues in quantitative proteomics. A systematic study was performed to assess ...the quantification performances of a novel quadrupole-Orbitrap instrument operated in MS/MS mode (parallel reaction monitoring). It included the analyses of 35 isotopically labeled peptides spiked in urine samples to establish their dilution curves. The results were evaluated by replicating the analyses on a triple quadrupole instrument operated in selected reaction monitoring (SRM; often referred as multiple reaction monitoring, MRM) mode to assess and compare the gain in selectivity resulting from high resolution fragment ion analysis. The high resolving power dramatically increased the selectivity of measurements by separating ions of interest from interferences, which occurred in several cases, and thus improved the quantification performance. In addition, an experiment to assess the “co-habitation” of fragment ions in specific regions of the LC-MS/MS spectral space of a complex proteome digest was carried out. The study included the evaluation of the fragmentation patterns acquired under various experimental conditions (i.e., quadrupole isolation windows and Orbitrap resolving powers) for more than 200 peptides, which provided an experimental baseline to guide the development of methods for parallel reaction monitoring acquisition. This article is part of a Special Issue entitled: From protein structures to clinical applications.
Display omitted
► Targeted proteomic quantification on a new quadrupole‐Orbitrap mass spectrometer. ► HR/AM increases selectivity and reliability of LC-MS/MS measurements. ► Quantification performance of PRM technique benefits from high resolution. ► Multiplexing capabilities enable large scale studies.
MS‐based approaches using targeted methods have been widely adopted by the proteomics community to study clinical questions such as the evaluation of biomarkers. At present, the most widely used ...targeted MS method is the SRM technique typically performed on a triple quadrupole instrument. However, the high analytical demands for performing clinical studies in combination with the extreme complexity of the samples involved are a serious challenge. The segmentation of the biomarker evaluation workflow has only partially alleviated these issues by differently balancing the analytical requirements and throughput at different stages of the process. The recent introduction of targeted high‐resolution and accurate‐mass analyses on fast sequencing mass spectrometers operated in parallel reaction monitoring (PRM) mode offers new avenues to conduct clinical studies and thus overcome some of the limitations of the triple quadrupole instrument. This article discusses the attributes and specificities of the PRM technique, in terms of experimental design, execution, and data analysis, and the implications for biomarker evaluation. The benefits of PRM on data quality and the impact on the consistency of results are highlighted and the definitive progress on the overall output of clinical studies, including high throughput, is discussed.
Selected reaction monitoring (SRM) uses sensitive and specific mass spectrometric assays to measure target analytes across multiple samples, but it has not been broadly applied in proteomics owing to ...the tedious assay development process for each protein. We describe a method based on crude synthetic peptide libraries for the high-throughput development of SRM assays. We illustrate the power of the approach by generating and applying validated SRM assays for all Saccharomyces cerevisiae kinases and phosphatases.
The ability to routinely analyze and quantitatively measure changes in protein phosphorylation on a proteome-wide scale is essential for biological and clinical research. We assessed the ability of ...three common phosphopeptide isolation methods (phosphoramidate chemistry (PAC), immobilized metal affinity chromatography (IMAC) and titanium dioxide) to reproducibly, specifically and comprehensively isolate phosphopeptides from complex mixtures. Phosphopeptides were isolated from aliquots of a tryptic digest of the cytosolic fraction of Drosophila melanogaster Kc167 cells and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry. Each method reproducibly isolated phosphopeptides. The methods, however, differed in their specificity of isolation and, notably, in the set of phosphopeptides isolated. The results suggest that the three methods detect different, partially overlapping segments of the phosphoproteome and that, at present, no single method is sufficient for a comprehensive phosphoproteome analysis.