Abstract
Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier ...(SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique).
The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model.
These studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.
Abstract A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information ...from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy weighting and a time-dependent threshold for enhancing energy deposits consistent with the timescale of evaporation neutrons. Additionally, it was observed to learn an energy-weighting indicative of longitudinal leakage correction. In addition, the method produced a linear detector response and outperformed a published control method regarding resolution for every particle energy studied.
Beam tests of directly coupled scintillator tiles with MPPC readout Abu-Ajamieh, F.; Blazey, G.; Cole, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2011, Letnik:
659, Številka:
1
Journal Article
Recenzirano
We report on the response to a proton beam of scintillator tiles directly coupled at the face of the tile to multi-pixel photon counters. Detailed measurements with protons show that flat tiles have ...high response near the photon counters while concave tiles have uniform response suggesting that tiles with this versatile configuration can be tailored to a desired uniformity. The beam response is in qualitative agreement with the response to a non-triggered radioactive source and reveals additional spatial features.
The experimental results on the performance of the Metal/Resistor/Semiconductor (MRS) photodiode in the strong magnetic field of 4.4
T, and the possible impact of the quench of the magnet at 4.5
T on ...sensor's operation are reported. In addition, the experimental results on the performance of the extruded scintillator and WLS fiber, and various LEDs in the magnetic fields of 1.8 and 2.3
T, respectively, are detailed. The measurement method used is being described. The results of the work agree with the expectations that the LED, MRS and scintillator are not exhibiting sensitivity to the magnetic field presence. This result is essential for the design of the future electron–positron linear collider detector.
The proposed silicon detector concept for the international linear collider has a barrel and end cap muon systems. The scintillator based muon system prototype has 256 scintillating strips, ...wavelength-shifting fibers, and clear fibers connected to multianode photo multiplier tubes (MAPMT). Six Hamamatsu H7546B tubes were used. To understand strip output, each of 384 MAPMT outputs was independently measured at a given luminous flux and the same photocathode to anode voltage of 800 V. For the test, a custom made source of light was used. The anode currents have a wide spread; for all tubes the maximum value is 5.23 times larger than the minimum value. The MAPMT cross talk was measured for one of the central inputs. The maximum cross talk value is about 4.9%. The average cross talk for the nearest four neighboring channels is 3.9%, for the farther four 1%. To assure reproducibility and repeatability of the measurements a double reference method was used.
Detailed measurements of the wavelength shifting fiber response to a stable and reliable light source are presented. Particulars about materials, a double reference method, and measurement technique ...are included. The fibers studied were several hundred Kuraray, Y-11, multiclad, 1.2-mm outer diameter wavelength shifting fibers, each cut from a reel to about one meter length. The fibers were polished, mirrored, and the mirrors were UV epoxy protected. Each fiber passed quality control requirements before installation. About 94% of the fibers tested have a response within 1% of the overall mean
We report observation of the electroweak production of single top quarks in ppover collisions at sqrts=1.96 TeV based on 2.3 fb(-1) of data collected by the D0 detector at the Fermilab Tevatron ...Collider. Using events containing an isolated electron or muon and missing transverse energy, together with jets originating from the fragmentation of b quarks, we measure a cross section of sigma(ppover --> tb + X, tqb + X) = 3.94 + or - 0.88 pb. The probability to measure a cross section at this value or higher in the absence of signal is 2.5 x 10(-7), corresponding to a 5.0 standard deviation significance for the observation.
We present a measurement of the W boson mass using data corresponding to 4.3 fb(-1) of integrated luminosity collected with the D0 detector during Run II at the Fermilab Tevatron pp collider. With a ...sample of 1,677,394 W → eν candidate events, we measure M(W) = 80.367 ± 0.026 GeV. This result is combined with an earlier D0 result determined using an independent Run II data sample, corresponding to 1 fb(-1) of integrated luminosity, to yield M(W) = 80.375 ± 0.023 GeV.
Investigation of a solid-state photodetector Beznosko, D.; Blazey, G.; Chakraborty, D. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2005, Letnik:
545, Številka:
3
Journal Article
Recenzirano
We present results on the operation and performance characteristics of the MRS (metal/resistor/semiconductor) photodiode. These include measurements of threshold characteristics, noise frequency, ...dependence of signal amplitude on the applied voltage and temperature, and stability as a function of time and radiation dose. The single photoelectron separation for this photosensor is demonstrated with a light emitting diode. The response of the photodetector to light produced in a scintillator is studied with cosmic ray muons and a
106Ru source. In addition, fiber-sensor alignment issues were evaluated. The results are promising and illustrate the potential use of MRS as photosensors in high-energy physics detectors.
Radiation tests of Hamamatsu multi-pixel photon counters Blazey, G.; Colston, J.; Dyshkant, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2019, Letnik:
927, Številka:
C
Journal Article
Recenzirano
Odprti dostop
Results of radiation tests of Hamamatsu 2.0 × 2.0 mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs, are presented (Hamamatsu, 0000). Distinct sets of eight MPPCs were ...exposed to four different 1 MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination levels were taken before and after irradiation. No significant deterioration in performance was observed for breakdown voltage, gain, and response. Noise rates increased significantly with irradiation. These studies were undertaken in the context of MPPC requirements for the Cosmic Ray Veto detector of the Mu2e experiment at the Fermi National Accelerator Laboratory.